Comparative Assessment of Methods for Estimating Tumor Volume and Standardized Uptake Value in 18F-FDG PET
Open accessThe DOI matches its Crossref record.
Abstract
UNLABELLED: In (18)F-FDG PET, tumors are often characterized by their metabolically active volume and standardized uptake value (SUV). However, many approaches have been proposed to estimate tumor volume and SUV from (18)F-FDG PET images, none of them being widely agreed upon. We assessed the accuracy and robustness of 5 methods for tumor volume estimates and of 10 methods for SUV estimates in a large variety of configurations. METHODS: PET acquisitions of an anthropomorphic phantom containing 17 spheres (volumes between 0.43 and 97 mL, sphere-to-surrounding-activity concentration ratios between 2 and 68) were used. Forty-one nonspheric tumors (volumes between 0.6 and 92 mL, SUV of 2, 4, and 8) were also simulated and inserted in a real patient (18)F-FDG PET scan. Four threshold-based methods (including one, T(bgd), accounting for background activity) and a model-based method (Fit) described in the literature were used for tumor volume measurements. The mean SUV in the resulting volumes were calculated, without and with partial-volume effect (PVE) correction, as well as the maximum SUV (SUV(max)). The parameters involved in the tumor segmentation and SUV estimation methods were optimized using 3 approaches, corresponding to getting the best of each method or testing each method in more realistic situations in which the parameters cannot be perfectly optimized. RESULTS: In the phantom and simulated data, the T(bgd) and Fit methods yielded the most accurate volume estimates, with mean errors of 2% +/- 11% and -8% +/- 21% in the most realistic situations. Considering the simulated data, all SUV not corrected for PVE had a mean bias between -31% and -46%, much larger than the bias observed with SUV(max) (-11% +/- 23%) or with the PVE-corrected SUV based on T(bgd) and Fit (-2% +/- 10% and 3% +/- 24%). CONCLUSION: The method used to estimate tumor volume and SUV greatly affects the reliability of the estimates. The T(bgd) and Fit methods yielded low errors in volume estimates in a broad range of situations. The PVE-corrected SUV based on T(bgd) and Fit were more accurate and reproducible than SUV(max).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Self-citationKinahan, P. E., & Fletcher, J. W. (2010) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2010.10.001 · Cited by 631
A review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
Metadata
- Authors
- Tylski, P., Stute, S., Grotus, N., Doyeux, K., Hapdey, S., Gardin, I., Vanderlinden, B., & Buvat, I.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2010-01-15
- Volume
- 51
- Issue
- 2
- Pages
- 268-276
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2119325900
- Cited by
- 142
- References
- 0
- FWCI
- 13.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative Assessment of Methods for Estimating Tumor Volume and Standardized Uptake Value in 18F-FDG PET. https://app.cochat.ai/papers/10.2967/jnumed.109.066241
- The paper
- Tylski, P., Stute, S., Grotus, N., Doyeux, K., Hapdey, S., Gardin, I., Vanderlinden, B., & Buvat, I. (2010). Comparative Assessment of Methods for Estimating Tumor Volume and Standardized Uptake Value in 18F-FDG PET. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.109.066241
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.