Repeatability of Metabolically Active Volume Measurements with18F-FDG and18F-FLT PET in Non–Small Cell Lung Cancer
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
UNLABELLED: In addition to tumor size measurements with CT, there is a need for quantitative measurements of metabolic active volumes, possibly adding to tracer uptake measurements in oncologic response evaluation with PET. The aim of this study was to evaluate the metabolic volume test-retest variability in (18)F-FDG and 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) PET studies for various commonly used volumes of interest (VOIs) and the dependence of that variability on lesion size and relative radiotracer uptake. METHODS: Twenty non-small cell lung cancer patients were scanned twice with (18)F-FDG (n = 11) or (18)F-FLT (n = 9). VOIs were defined on images reconstructed with normalization- and attenuation-weighted ordered-subset expectation maximization using 4 isocontours (A41%, A50%, and A70% thresholds, adapted for local background, and 50% threshold, uncorrected for background). Statistical analysis comprised intraclass correlation coefficients and Bland-Altman analysis. RESULTS: In the (18)F-FDG and (18)F-FLT groups, 34 and 20 lesions, respectively, were analyzed. Median volumes at the A50% threshold were 3.31 and 2.19 mL (interquartile range, 1.91-8.90 and 1.52-7.27 mL) for (18)F-FDG and (18)F-FLT, respectively. Intraclass correlation coefficients were greater than 0.9, with the exception of the A70%-based metabolic volumes for (18)F-FLT. For lesions greater than 4.2 mL, repeatability coefficients (RCs = 1.96 × SD) of the percentage difference ranged from 22% to 37% for (18)F-FDG and from 39% to 73% for (18)F-FLT, depending on the VOI method being used. Repeatability was better for larger tumors, but there was no dependence on absolute uptake (standardized uptake value). CONCLUSION: Results indicate that changes of greater than 37% for (18)F-FDG and greater than 73% for (18)F-FLT (1.96 × SD) for lesions with A50% metabolic volumes greater than 4.2 mL represent a biologic effect. For smaller lesions (A50% VOI < 4.2 mL), an absolute change of 1.0 and 0.9 mL for (18)F-FDG and (18)F-FLT, respectively, is biologically relevant. Considering the balance between the success rate of automatic tumor delineation and repeatability of metabolic volume, a 50% threshold with correction for local background activity (A50%) seems optimal among the VOI methods evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065 · cited 1×
“The impact of clustered observations (multiple pairs of measurements of different lesions on the same subject) was studied bymeans of mixed-effects models and, if necessary, corrected (12,13).”
Background
Cited by
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
“[82] Frings V, de Langen AJ, Smit EF et al.”
Self-citationLeijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Self-citationTixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
Hatt, M., Lee, J. A., Schmidtlein, C. R., Naqa, I. E., Caldwell, C., De Bernardi, E., Lu, W., Das, S., Geets, X., Gregoire, V., et al. (2017) · Medical Physics · doi:10.1002/mp.12124 · Cited by 198
Meignan, M., Sasanelli, M., Casasnovas, R. O., Luminari, S., Fioroni, F., Coriani, C., Masset, H., Itti, E., Gobbi, P. G., Merli, F., et al. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2705-y · Cited by 186
Metadata
- Authors
- Frings, V., de Langen, A. J., Smit, E. F., van Velden, F. H. P., Hoekstra, O. S., van Tinteren, H., & Boellaard, R.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2010-11-15
- Volume
- 51
- Issue
- 12
- Pages
- 1870-1877
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2112858145
- Cited by
- 111
- References
- 1
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.