CoChat

Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization

Kao, Yung Hsiang, Hock Tan, Andrew Eik, Burgmans, Mark Christiaan, Irani, Farah Gillian, Khoo, Li Ser, Gong Lo, Richard Hoau, Tay, Kiang Hiong, Tan, Bien Soo, Hoe Chow, Pierce Kah, Eng Ng, David Chee, Whatt Goh, Anthony Soon · 2012 · Journal of Nuclear Medicine
Cited by 164

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Compliance with radiobiologic principles of radionuclide internal dosimetry is fundamental to the success of (90)Y radioembolization. The artery-specific SPECT/CT partition model is an image-guided personalized predictive dosimetric technique developed by our institution, integrating catheter-directed CT hepatic angiography (CTHA), (99m)Tc-macroaggregated albumin SPECT/CT, and partition modeling for unified dosimetry. Catheter-directed CTHA accurately delineates planning target volumes. SPECT/CT tomographically evaluates (99m)Tc-macroaggregated albumin hepatic biodistribution. The partition model is validated for (90)Y resin microspheres based on MIRD macrodosimetry. METHODS: This was a retrospective analysis of our early clinical outcomes for inoperable hepatocellular carcinoma. Mapping hepatic angiography was performed according to standard technique with the addition of catheter-directed CTHA. (99m)Tc-MAA planar scintigraphy was used for liver-to-lung shunt estimation, and SPECT/CT was used for liver dosimetry. Artery-specific SPECT/CT partition modeling was planned by experienced nuclear medicine physicians. RESULTS: From January to May 2011, 20 arterial territories were treated in 10 hepatocellular carcinoma patients. Median follow-up was 21 wk (95% confidence interval [CI], 12-50 wk). When analyzed strictly as brachytherapy, (90)Y radioembolization planned by predictive dosimetry achieved index tumor regression in 8 of 8 patients, with a median size decrease of 58% (95% CI, 40%-72%). Tumor thrombosis regressed or remained stable in 3 of 4 patients with baseline involvement. The best α-fetoprotein reduction ranged from 32% to 95%. Clinical success was achieved in 7 of 8 patients, including 2 by sublesional dosimetry, in 1 of whom there was radioembolization lobectomy intent. Median predicted mean radiation absorbed doses were 106 Gy (95% CI, 105-146 Gy) to tumor, 27 Gy (95% CI, 22-33 Gy) to nontumorous liver, and 2 Gy (95% CI, 1.3-7.3 Gy) to lungs. Across all patients, tumor, nontumorous liver, and lungs received predicted ≥91 Gy, ≤51 Gy, and ≤16 Gy, respectively, via at least 1 target arterial territory. No patients developed significant toxicities within 3 mo after radioembolization. The median time to best imaging response was 76 d (95% CI, 55-114 d). Median time to progression and overall survival were not reached. SPECT/CT-derived mean tumor-to-normal liver ratios varied widely across all planning target volumes (median, 5.4; 95% CI, 4.1-6.7), even within the same patient. CONCLUSION: Image-guided personalized predictive dosimetry by artery-specific SPECT/CT partition modeling achieves high clinical success rates for safe and effective (90)Y radioembolization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.111.097469

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Kao, Y. H., Hock Tan, A. E., Burgmans, M. C., Irani, F. G., Khoo, L. S., Gong Lo, R. H., Tay, K. H., Tan, B. S., Hoe Chow, P. K., Eng Ng, D. C., & Whatt Goh, A. S.
Venue
Journal of Nuclear Medicine
Published
2012-02-17
Volume
53
Issue
4
Pages
559-566
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2128553182
Cited by
164
References
22
FWCI
11.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.