The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Reproducibility of Tumor Uptake Heterogeneity Characterization Through Textural Feature Analysis in 18F-FDG PET
Open accessAbstract
UNLABELLED: (18)F-FDG PET measurement of standardized uptake value (SUV) is increasingly used for monitoring therapy response and predicting outcome. Alternative parameters computed through textural analysis were recently proposed to quantify the heterogeneity of tracer uptake by tumors as a significant predictor of response. The primary objective of this study was to evaluate the reproducibility of these heterogeneity measurements. METHODS: Double baseline (18)F-FDG PET scans were acquired within 4 d of each other for 16 patients before any treatment was considered. A Bland-Altman analysis was performed on 8 parameters based on histogram measurements and 17 parameters based on textural heterogeneity features after discretization with values between 8 and 128. RESULTS: The reproducibility of maximum and mean SUV was similar to that in previously reported studies, with a mean percentage difference of 4.7% ± 19.5% and 5.5% ± 21.2%, respectively. By comparison, better reproducibility was measured for some textural features describing local heterogeneity of tracer uptake, such as entropy and homogeneity, with a mean percentage difference of -2% ± 5.4% and 1.8% ± 11.5%, respectively. Several regional heterogeneity parameters such as variability in the intensity and size of regions of homogeneous activity distribution had reproducibility similar to that of SUV measurements, with 95% confidence intervals of -22.5% to 3.1% and -1.1% to 23.5%, respectively. These parameters were largely insensitive to the discretization range. CONCLUSION: Several parameters derived from textural analysis describing heterogeneity of tracer uptake by tumors on local and regional scales had reproducibility similar to or better than that of simple SUV measurements. These reproducibility results suggest that these (18)F-FDG PET-derived parameters, which have already been shown to have predictive and prognostic value in certain cancer models, may be used to monitor therapy response and predict patient outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Self-citationExploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424
Kunkel, M., Reichert, T. E., Benz, P., Lehr, H., Jeong, J., Wieand, S., Bartenstein, P., Wagner, W., & Whiteside, T. L. (2003) · Cancer · doi:10.1002/cncr.11159 · Cited by 390
Reproducibility of metabolic measurements in malignant tumors using FDG PET.
Weber, W., Ziegler, S. I., Thödtmann, R., Hanauske, A.-R., & Schwaiger, M. (1999) · PubMed · Cited by 388
Texture Indexes and Gray Level Size Zone Matrix Application to Cell Nuclei Classification
Thibault, G., Fertil, B., Navarro, C. L., Pereira, S., Cau, P., Lévy, N., Séqueira, J., & Mari, J.-L. (2009) · HAL · Cited by 375
Rajendran, J. G., Schwartz, D. L., O'Sullivan, J., Peterson, L. M., Ng, P., Scharnhorst, J., Grierson, J. R., & Krohn, K. A. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-1773 · Cited by 354
Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
Within-patient variability of (18)F-FDG: standardized uptake values in normal tissues.
Paquet, N., Albert, A., Foidart, J., & Hustinx, R. (2004) · PubMed · Cited by 257
Nahmias, C., & Wahl, L. M. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054239 · Cited by 200
Hatt, M., Visvikis, D., Albarghach, N. M., Tixier, F., Pradier, O., & Rest, C. C. L. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1755-7 · Cited by 151
Self-citationReproducibility of 18F-FDG and 3′-Deoxy-3′-18F-Fluorothymidine PET Tumor Volume Measurements
Hatt, M., Rest, C. C. L., Aboagye, E. O., Kenny, L. M., Rosso, L., Turkheimer, F., Albarghach, N. M., Metges, J., Pradier, O., & Visvikis, D. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.078501 · Cited by 125
Self-citationFrings, V., de Langen, A. J., Smit, E. F., van Velden, F. H. P., Hoekstra, O. S., van Tinteren, H., & Boellaard, R. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.077255 · Cited by 109
Basu, S. K., Kwee, T. C., Gatenby, R. A., Saboury, B., Torigian, D. A., & Alavi, A. A. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1787-z · Cited by 93
Cazaentre, T., Morschhauser, F., Vermandel, M., Betrouni, N., Prangère, T., Steinling, M., & Huglo, D. G. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1275-x · Cited by 80
FDG PET/CT Evaluation of Treatment Response in Patients With Recurrent Colorectal Cancer
Shamim, S. A., Kumar, R., Shandal, V., Halanaik, D., Kumar, G., Bal, C. S., & Malhotra, A. (2010) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e3181feeb48 · Cited by 13
Cited by
Computational Radiomics System to Decode the Radiographic Phenotype
(2017) · doi:10.1158/0008-5472.can-17-0339 · Cited by 6,593
Mayerhoefer, M. E., Materka, A., Langs, G., Häggström, I., Szczypiński, P., Gibbs, P., & Cook, G. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.222893 · Cited by 1,777
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Imaging Intratumor Heterogeneity: Role in Therapy Response, Resistance, and Clinical Outcome
O'Connor, J. P. B., Rose, C. J., Waterton, J. C., Carano, R. A. D., Parker, G. J. M., & Jackson, A. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-0990 · Cited by 677
Metadata
- Authors
- Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-03-27
- Volume
- 53
- Issue
- 5
- Pages
- 693-700
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2099835501
- Cited by
- 318
- References
- 19
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.