Compared Performance of High-Sensitivity Cameras Dedicated to Myocardial Perfusion SPECT: A Comprehensive Analysis of Phantom and Human Images
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Differences in the performance of cadmium-zinc-telluride (CZT) cameras or collimation systems that have recently been commercialized for myocardial SPECT remain unclear. In the present study, the performance of 3 of these systems was compared by a comprehensive analysis of phantom and human SPECT images. METHODS: We evaluated the Discovery NM 530c and DSPECT CZT cameras, as well as the Symbia Anger camera equipped with an astigmatic (IQ x SPECT) or parallel-hole (conventional SPECT) collimator. Physical performance was compared on reconstructed SPECT images from a phantom and from comparable groups of healthy subjects. RESULTS: Classifications were as follows, in order of performance. For count sensitivity on cardiac phantom images (counts x s(-1) x MBq(-1)), DSPECT had a sensitivity of 850; Discovery NM 530c, 460; IQ x SPECT, 390; and conventional SPECT, 130. This classification was similar to that of myocardial counts normalized to injected activities from human images (respective mean values, in counts x s(-1) x MBq(-1): 11.4 ± 2.6, 5.6 ± 1.4, 2.7 ± 0.7, and 0.6 ± 0.1). For central spatial resolution: Discovery NM 530c was 6.7 mm; DSPECT, 8.6 mm; IQ x SPECT, 15.0 mm; and conventional SPECT, 15.3 mm, also in accordance with the analysis of the sharpness of myocardial contours on human images (in cm(-1): 1.02 ± 0.17, 0.92 ± 0.11, 0.64 ± 0.12, and 0.65 ± 0.06, respectively). For contrast-to-noise ratio on the phantom: Discovery NM 530c had a ratio of 4.6; DSPECT, 4.1; IQ x SPECT, 3.9; and conventional SPECT, 3.5, similar to ratios documented on human images (5.2 ± 1.0, 4.5 ± 0.5, 3.9 ± 0.6, and 3.4 ± 0.3, respectively). CONCLUSION: The performance of CZT cameras is dramatically higher than that of Anger cameras, even for human SPECT images. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with the Discovery NM 530c, whereas count sensitivity is markedly higher with the DSPECT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1488-z · Cited by 303
A Novel High-Sensitivity Rapid-Acquisition Single-Photon Cardiac Imaging Camera
Gambhir, S. S., Berman, D. S., Ziffer, J. A., Nagler, M., Sandler, M. P., Patton, J. A., Hutton, B. F., Sharir, T., Haim, S. B., & Ben‐Haim, S. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.060020 · Cited by 266
Advances in technical aspects of myocardial perfusion SPECT imaging
Slomka, P. J., Patton, J. A., Berman, D. S., & Germano, G. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-009-9052-6 · Cited by 240
High-Speed Myocardial Perfusion Imaging
Sharir, T., Ben-Haim, S., Merzon, K., Prochorov, V., Dickman, D., Ben-Haim, S., & Berman, D. S. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.004 · Cited by 234
Recent technologic advances in nuclear cardiology
Patton, J. A., Slomka, P. J., Germano, G., & Berman, D. S. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2007.06.003 · Cited by 121
Mouden, M., Timmer, J. R., Ottervanger, J. P., Reiffers, S., Oostdijk, A. H. J., Knollema, S., & Jager, P. L. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2086-z · Cited by 98
Comparison of high efficiency CZT SPECT MPI to coronary angiography
Duvall, W. L., Sweeny, J. M., Croft, L. B., Barghash, M. H., Kulkarni, N. K., Guma, K. A., & Henzlova, M. J. (2011) · Journal of Nuclear Cardiology · doi:10.1007/s12350-011-9382-z · Cited by 72
Semiconductor Detectors Allow Low-Dose–Low-Dose 1-Day SPECT Myocardial Perfusion Imaging
Nkoulou, R. N., Pazhenkottil, A. P., Kuest, S. M., Ghadri, J. R., Wolfrum, M., Husmann, L., Fiechter, M., Buechel, R. R., Herzog, B. A., Koepfli, P., et al. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.085415 · Cited by 62
Pazhenkottil, A. P., Buechel, R. R., Herzog, B. A., Nkoulou, R. N., Valenta, I., Fehlmann, U., Ghadri, J. R., Wolfrum, M., Husmann, L., & Kaufmann, P. A. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1507-0 · Cited by 45
New Trends in Camera and Software Technology in Nuclear Cardiology
Garcia, E. V., & Faber, T. L. (2009) · Cardiology Clinics · doi:10.1016/j.ccl.2008.12.002 · Cited by 41
Poussier, S., Maskali, F., Tran, N., Person, C., Maureira, P., Boutley, H., Karcher, G., Lacolley, P. J., Regnault, V., Fay, R., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1418-0 · Cited by 23
Self-citationRegional Flow Responses to Exercise
Carù, B., Colombo, E., Santoro, F., Laporta, A., & Maslowsky, F. (1992) · CHEST Journal · doi:10.1378/chest.101.5_supplement.223s · Cited by 19
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Radiopharmaceuticals for PET and SPECT Imaging: A Literature Review over the Last Decade
Crișan, G., Moldovean-Cioroianu, N. S., Timaru, D.-G., Andrieș, G., Căinap, C., & Chiș, V. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23095023 · Cited by 337
Dynamic whole-body PET imaging: principles, potentials and applications
Rahmim, A., Lodge, M. A., Karakatsanis, N. A., Panin, V. Y., Zhou, Y., McMillan, A., Cho, S., Zaidi, H., Casey, M. E., & Wahl, R. L. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4153-6 · Cited by 273
Salvadori, J., Imbert, L., Perrin, M., Karcher, G., Lamiral, Z., Marie, P.-Y., & Verger, A. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0526-5 · Cited by 44
Self-citation
Metadata
- Authors
- Imbert, L., Poussier, S., Franken, P. R., Songy, B., Verger, A., Morel, O., Wolf, D., Noel, A., Karcher, G., & Marie, P.-Y.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-11-08
- Volume
- 53
- Issue
- 12
- Pages
- 1897-1903
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2107892208
- Cited by
- 267
- References
- 12
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.