The DOI matches its Crossref record.
Detection of Recurrent Prostate Cancer After Radical Prostatectomy: Comparison of 11C-Choline PET/CT with Pelvic Multiparametric MR Imaging with Endorectal Coil
Open accessAbstract
UNLABELLED: The aim of this study was to compare (11)C-choline PET/CT with pelvic multiparametric MR imaging for detection of recurrent prostate carcinoma in patients with suspected recurrence after radical prostatectomy and to identify an optimal imaging method to restage these patients. METHODS: This was a retrospective, single-institution study of 115 prostatectomy patients with suspected tumor recurrence who underwent both (11)C-choline PET/CT and multiparametric MR imaging with endorectal coil. The reference standard included histopathology, treatment change, and imaging follow-up for determination of locally recurrent tumor, lymph node (LN) metastases, and skeletal metastases. Two nuclear medicine and 2 genitourinary radiologists independently and in a masked manner reviewed PET/CT and multiparametric MR imaging, respectively. The reviewers assessed for local recurrence in the prostatectomy bed as well as LN and bone metastases, rating their diagnostic confidence with a 5-point scoring system for each location. Receiver-operating-characteristic analysis was used to compare the 2 modalities. RESULTS: The standard of reference (either positive or negative) for the diagnosis of local recurrence and pelvic LN and bone metastases was met in 87, 70, and 95 patients, respectively. Documented local recurrence and pelvic LN and bone metastases was present in 61 of 87 (70.1%), 50 of 70 (71.4%), and 16 of 95 (16.8%) patients, respectively. Patient-based area under the receiver-operating-characteristic curves of multiparametric MR imaging versus PET/CT for the diagnosis of local recurrence and pelvic LN and bone metastases were 0.909 versus 0.761 (P = 0.0079), 0.812 versus 0.952 (P = 0.0064), and 0.927 versus 0.898 (P = 0.69), respectively. Among 61 patients with local recurrence, 32 patients (52.4%) were correctly diagnosed as having local recurrence by both multiparametric MR imaging and PET/CT, 22 (36.1%) were correctly diagnosed by multiparametric MR imaging only, 6 (9.8%) could not be diagnosed by either modality, and 1 (1.6%) was correctly diagnosed by PET/CT only. The patient-based sensitivity, specificity, and accuracy of multiparametric MR imaging for diagnosing local recurrence were 88.5% (54/61), 84.6% (22/26), and 87.4% (76/87) whereas those of PET/CT for detecting body LN or bone metastases were 92.3% (72/78), 100% (18/18), and 93.8% (90/96), respectively. CONCLUSION: Multiparametric MR imaging with endorectal coil is superior for the detection of local recurrence, PET/CT is superior for pelvic LN metastasis, and both were equally excellent for pelvic bone metastasis. (11)C-choline PET/CT and pelvic multiparametric MR imaging are complementary for restaging prostatectomy patients with suspected recurrent disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhan, T., Rindtorff, N., & Boutros, M. (2017) · Oncogene · doi:10.1038/onc.2016.304 · Cited by 2,626
WNT signalling in prostate cancer
Murillo-Garzón, V., & Kypta, R. (2017) · Nature Reviews Urology · doi:10.1038/nrurol.2017.144 · Cited by 361
Metadata
- Authors
- Kitajima, K., Murphy, R. C., Nathan, M. A., Froemming, A. T., Hagen, C. E., Takahashi, N., & Kawashima, A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2014-01-16
- Volume
- 55
- Issue
- 2
- Pages
- 223-232
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2145801780
- Cited by
- 200
- References
- 0
- FWCI
- 22.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Recurrent Prostate Cancer After Radical Prostatectomy: Comparison of 11C-Choline PET/CT with Pelvic Multiparametric MR Imaging with Endorectal Coil. https://app.cochat.ai/papers/10.2967/jnumed.113.123018
- The paper
- Kitajima, K., Murphy, R. C., Nathan, M. A., Froemming, A. T., Hagen, C. E., Takahashi, N., & Kawashima, A. (2014). Detection of Recurrent Prostate Cancer After Radical Prostatectomy: Comparison of 11C-Choline PET/CT with Pelvic Multiparametric MR Imaging with Endorectal Coil. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.113.123018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.