The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Clinical Cerenkov Luminescence Imaging of18F-FDG
Open accessAbstract
UNLABELLED: The aim of this study was to determine the feasibility of Cerenkov luminescence (CL) imaging of patients undergoing diagnostic (18)F-FDG scans to detect nodal disease. METHODS: Patients undergoing routine (18)F-FDG PET/CT for various malignancies consented to being scanned for CL. White-light and Cerenkov images (5-min acquisition) of the surface of the patient contralateral to and at the site of nodal (18)F-FDG uptake were acquired using a cooled, intensified charge-coupled-device camera. RESULTS: The camera demonstrated linear correlation between activity and counts into the low nanocurie range using (18)F-FDG. Imaging of patients revealed the presence of (18)F-FDG uptake in nodes that demonstrated uptake on PET. A correlation between maximum standardized uptake value from PET and counting rate per area on the CL imaging was established. CONCLUSION: CL imaging with diagnostic doses of (18)F-FDG is feasible and can aid in detecting disease in the clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Time course to hypothyroidism after fixed-dose radioablation therapy of Graves' disease in children
Nebesio, T. D., Siddiqui, A. R., Pescovitz, O. H., & Eugster, E. A. (2002) · The Journal of Pediatrics · doi:10.1067/mpd.2002.125494 · Cited by 66
Cited by
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Chi, C., Du, Y., Ye, J., Kou, D., Qiu, J., Wang, J., Tian, J., & Chen, X. (2014) · Theranostics · doi:10.7150/thno.9899 · Cited by 358
Metadata
- Authors
- Thorek, D. L. J., Riedl, C. C., & Grimm, J.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2013-09-27
- Volume
- 55
- Issue
- 1
- Pages
- 95-98
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2164273655
- Cited by
- 166
- References
- 2
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Cerenkov Luminescence Imaging of18F-FDG. https://app.cochat.ai/papers/10.2967/jnumed.113.127266
- The paper
- Thorek, D. L. J., Riedl, C. C., & Grimm, J. (2014). Clinical Cerenkov Luminescence Imaging of18F-FDG. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.113.127266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.