Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 236

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Safety and Efficacy of 68Ga-DOTATATE PET/CT for Diagnosis, Staging, and Treatment Management of Neuroendocrine Tumors

Open access
Deppen, Stephen A., Liu, Eric, Blume, Jeffrey D., Clanton, Jeffrey, Shi, Chanjuan, Jones-Jackson, Laurie B., Lakhani, Vipul, Baum, Richard P., Berlin, Jordan, Smith, Gary T., Graham, Michael, Sandler, Martin P., Delbeke, Dominique, Walker, Ronald C. · 2016 · Journal of Nuclear Medicine

Abstract

UNLABELLED: Our purpose was to evaluate the safety and efficacy of (68)Ga-DOTATATE PET/CT compared with (111)In-pentetreotide imaging for diagnosis, staging, and restaging of pulmonary and gastroenteropancreatic neuroendocrine tumors. METHODS: (68)Ga-DOTATATE PET/CT and (111)In-pentetreotide scans were obtained for 78 of 97 consecutively enrolled patients with known or suspected pulmonary or gastroenteropancreatic neuroendocrine tumors. Safety and toxicity were measured by comparing vital signs, serum chemistry values, or acquisition-related medical complications before and after (68)Ga-DOTATATE injection. Added value was determined by changes in treatment plan when (68)Ga-DOTATATE PET/CT results were added to all prior imaging, including (111)In-pentetreotide. Interobserver reproducibility of (68)Ga-DOTATATE PET/CT scan interpretation was measured between blinded and nonblinded interpreters. RESULTS: (68)Ga-DOTATATE PET/CT and (111)In-pentetreotide scans were significantly different in impact on treatment (P < 0.001). (68)Ga-DOTATATE PET/CT combined with CT or liver MRI changed care in 28 of 78 (36%) patients. Interobserver agreement between blinded and nonblinded interpreters was high. No participant had a trial-related event requiring treatment. Mild, transient events were tachycardia in 1, alanine transaminase elevation in 1, and hyperglycemia in 2 participants. No clinically significant arrhythmias occurred. (68)Ga-DOTATATE PET/CT correctly identified 3 patients for peptide-receptor radiotherapy incorrectly classified by (111)In-pentetreotide. CONCLUSION: (68)Ga-DOTATATE PET/CT was equivalent or superior to (111)In-pentetreotide imaging in all 78 patients. No adverse events requiring treatment were observed. (68)Ga-DOTATATE PET/CT changed treatment in 36% of participants. Given the lack of significant toxicity, lower radiation exposure, and improved accuracy compared with (111)In-pentetreotide, (68)Ga-DOTATATE imaging should be used instead of (111)In-pentetreotide imaging where available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.115.163865

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 236

Metadata

Authors
Deppen, S. A., Liu, E., Blume, J. D., Clanton, J., Shi, C., Jones-Jackson, L. B., Lakhani, V., Baum, R. P., Berlin, J., Smith, G. T., Graham, M., Sandler, M. P., Delbeke, D., & Walker, R. C.
Venue
Journal of Nuclear Medicine
Published
2016-01-14
Volume
57
Issue
5
Pages
708-714
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2343075275
Cited by
236
References
2
FWCI
23.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.