The DOI matches its Crossref record.
68Ga-PSMA PET/CT Detects the Location and Extent of Primary Prostate Cancer
Open accessAbstract
We evaluated the accuracy of PET/CT with 68Ga-PSMA-HBED-CC—a 68Ga-conjugated ligand of human prostate-specific membrane antigen (PSMA)—to localize cancer in the prostate and surrounding tissue at initial diagnosis. Methods: Twenty-one patients with biopsy-proven prostate cancer underwent 68Ga-PSMA-HBED-CC (68Ga-PSMA) PET/CT at a median of 4 d (range, 0–47 d) before radical prostatectomy. Based on a 6-segment model, the Gleason score and proportion of tumor tissue within each segment (segmental tumor burden, or STB) as determined by histopathology (STBHP) were correlated with SUVmax and STB as determined by different SUV cutoffs for 68Ga-PSMA PET (STBPET1–6). Furthermore, the involvement of seminal vesicles and other extracapsular extension were assessed by histopathology and PET/CT. Results: Histopathology-positive segments (n = 100 of 126; 79%) demonstrated a significantly higher mean ± SD SUVmax (11.8 ± 7.6) than histopathology-negative segments (4.9 ± 2.9; P < 0.001). Receiver-operating-characteristic analysis revealed an optimal SUVmax cutoff of 6.5 for discrimination of histopathology-positive segments from histopathology-negative segments (area under the curve, 0.84; P < 0.001), which gave 67% sensitivity, 92% specificity, a 97% positive predictive value, a 42% negative predictive value, and 72% accuracy. STBPET3 as determined by (2 × blood SUV) + (2 × SD) correlated best with STBHP (Pearson ρ = 0.68; P < 0.001; mean difference ± SD, 19% ± 15%). PET/CT correctly detected invasion of seminal vesicles (n = 11 of 21 patients; 52%) with 86% accuracy and tumor spread through the capsule (n = 12; 57%) with 71% accuracy. Conclusion:68Ga-PSMA PET/CT accurately detected the location and extent of primary prostate cancer. Our preliminary findings warrant further investigation of 68Ga-PSMA PET/CT in conjunction with needle biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Eiber, M., Herrmann, K., Calais, J., Hadaschik, B., Giesel, F. L., Hartenbach, M., Hope, T., Reiter, R., Maurer, T., Weber, W. A., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.198119 · Cited by 626
Self-citationGiesel, F. L., Hadaschik, B., Cardinale, J., Radtke, J., Vinsensia, M., Lehnert, W., Kesch, C., Tolstov, Y., Singer, S., Grabe, N., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3573-4 · Cited by 592
Hofman, M. S., Hicks, R. J., Maurer, T., & Eiber, M. (2018) · RadioGraphics · doi:10.1148/rg.2018170108 · Cited by 383
Seifert, R., Emmett, L., Rowe, S. P., Herrmann, K., Hadaschik, B., Calais, J., Giesel, F. L., Reiter, R., Maurer, T., Heck, M., et al. (2023) · European Urology · doi:10.1016/j.eururo.2023.02.002 · Cited by 313
Self-citationvon Eyben, F. E., Picchio, M., von Eyben, R., Rhee, H., & Bauman, G. (2018) · European Urology Focus · doi:10.1016/j.euf.2016.11.002 · Cited by 257
Metadata
- Authors
- Fendler, W. P., Schmidt, D. F., Wenter, V., Thierfelder, K. M., Zach, C., Stief, C., Bartenstein, P., Kirchner, T., Gildehaus, F. J., Gratzke, C., & Faber, C.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2016-06-03
- Volume
- 57
- Issue
- 11
- Pages
- 1720-1725
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2410782911
- Cited by
- 202
- References
- 0
- FWCI
- 23.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 68Ga-PSMA PET/CT Detects the Location and Extent of Primary Prostate Cancer. https://app.cochat.ai/papers/10.2967/jnumed.116.172627
- The paper
- Fendler, W. P., Schmidt, D. F., Wenter, V., Thierfelder, K. M., Zach, C., Stief, C., Bartenstein, P., Kirchner, T., Gildehaus, F. J., Gratzke, C., & Faber, C. (2016). 68Ga-PSMA PET/CT Detects the Location and Extent of Primary Prostate Cancer. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.116.172627
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.