68Ga-PSMA PET/CT Detects the Location and Extent of Primary Prostate Cancer
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We evaluated the accuracy of PET/CT with 68Ga-PSMA-HBED-CC—a 68Ga-conjugated ligand of human prostate-specific membrane antigen (PSMA)—to localize cancer in the prostate and surrounding tissue at initial diagnosis. Methods: Twenty-one patients with biopsy-proven prostate cancer underwent 68Ga-PSMA-HBED-CC (68Ga-PSMA) PET/CT at a median of 4 d (range, 0–47 d) before radical prostatectomy. Based on a 6-segment model, the Gleason score and proportion of tumor tissue within each segment (segmental tumor burden, or STB) as determined by histopathology (STBHP) were correlated with SUVmax and STB as determined by different SUV cutoffs for 68Ga-PSMA PET (STBPET1–6). Furthermore, the involvement of seminal vesicles and other extracapsular extension were assessed by histopathology and PET/CT. Results: Histopathology-positive segments (n = 100 of 126; 79%) demonstrated a significantly higher mean ± SD SUVmax (11.8 ± 7.6) than histopathology-negative segments (4.9 ± 2.9; P < 0.001). Receiver-operating-characteristic analysis revealed an optimal SUVmax cutoff of 6.5 for discrimination of histopathology-positive segments from histopathology-negative segments (area under the curve, 0.84; P < 0.001), which gave 67% sensitivity, 92% specificity, a 97% positive predictive value, a 42% negative predictive value, and 72% accuracy. STBPET3 as determined by (2 × blood SUV) + (2 × SD) correlated best with STBHP (Pearson ρ = 0.68; P < 0.001; mean difference ± SD, 19% ± 15%). PET/CT correctly detected invasion of seminal vesicles (n = 11 of 21 patients; 52%) with 86% accuracy and tumor spread through the capsule (n = 12; 57%) with 71% accuracy. Conclusion:68Ga-PSMA PET/CT accurately detected the location and extent of primary prostate cancer. Our preliminary findings warrant further investigation of 68Ga-PSMA PET/CT in conjunction with needle biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777 · cited 2×
“A reference SUV was determined in liver, blood, and parotid glands on the basis of the following respective definitions: mean SUV in a 3-cm-diameter spheric volume of interest placed in the center of the right hepatic lobe (SUVliver) and in a 1-cm-diameter spheric volume of interest in the descending thoracic aorta, i…”
MethodEpstein, J. I., Allsbrook, W. C., Amin, M. B., & Egevad, L. L. (2005) · American Journal of Surgical Pathology · doi:10.1097/01.pas.0000173646.99337.b1 · Cited by 2,763 · cited 1×
“Grading was performed according to the International Society of Urological Pathology 2005 modified GS system (10).”
MethodAfshar-Oromieh, A., Avtzi, E., Giesel, F. L., Holland-Letz, T., Linhart, H. G., Eder, M., Eisenhut, M., Boxler, S., Hadaschik, B. A., Kratochwil, C., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2949-6 · Cited by 964
Afshar-Oromieh, A., Zechmann, C. M., Malcher, A., Eder, M., Eisenhut, M., Linhart, H. G., Holland-Letz, T., Hadaschik, B. A., Giesel, F. L., Debus, J., et al. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2525-5 · Cited by 921 · cited 2×
“The slightly higher accuracy of 68Ga-PSMA PET might, notwithstanding group differences in patient cohort and sample analysis, be due to inherently superior tumor-to-background uptake for 68Ga-PSMA as compared with 18F-choline (6).”
BackgroundBostwick, D. G., Pacelli, A., Blute, M., Roche, P., & Murphy, G. P. (1998) · Cancer · doi:10.1002/(sici)1097-0142(19980601)82:11<2256::aid-cncr22>3.0.co;2-s · Cited by 698
Weineisen, M., Schottelius, M., Simecek, J., Baum, R. P., Yildiz, A., Beykan, S., Kulkarni, H. R., Lassmann, M., Klette, I., Eiber, M., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.158550 · Cited by 532
Mannweiler, S., Amersdorfer, P., Trajanoski, S., Terrett, J. A., King, D., & Mehes, G. (2009) · Pathology & Oncology Research · doi:10.1007/s12253-008-9104-2 · Cited by 384
Sonn, G. A., Chang, E., Natarajan, S., Margolis, D. J., Macairan, M., Lieu, P., Huang, J., Dorey, F. J., Reiter, R. E., & Marks, L. S. (2014) · European Urology · doi:10.1016/j.eururo.2013.03.025 · Cited by 371 · cited 1×
“Multiparametric MRI shows promising results for localizing prostate cancer and improves the accuracy of ultrasound-guided biopsy (1,2).”
BackgroundMuller, B. G., Shih, J. H., Sankineni, S., Marko, J., Rais-Bahrami, S., George, A. K., de la Rosette, J. J. M. C. H., Merino, M. J., Wood, B. J., Pinto, P., et al. (2015) · Radiology · doi:10.1148/radiol.2015142818 · Cited by 331 · cited 2×
“Despite important advances such as standardized reporting, considerable interobserver variability remains a major drawback for MRI (3), resulting in the overall heterogeneous accuracy reported in the literature (4).”
Background18F-DCFBC PET/CT for PSMA-Based Detection and Characterization of Primary Prostate Cancer
Rowe, S. P., Gage, K. L., Faraj, S. F., Macura, K. J., Cornish, T. C., Gonzalez-Roibon, N., Guner, G., Munari, E., Partin, A. W., Pavlovich, C. P., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.154336 · Cited by 196 · cited 1×
“, in their prospective analyses of the performance of PET/CT in conjunction with MRI using the 18F-labeled PSMA ligand 18F-DCFBC (N-[N-[(S)-1,3-dicarboxypropyl]carbamoyl]4-18F-fluorobenzyl-L-cysteine) for detection of primary prostate cancer in 13 patients (14), reported lower accuracy for PET (57%) than for MRI (65%).”
Cited by
Eiber, M., Herrmann, K., Calais, J., Hadaschik, B., Giesel, F. L., Hartenbach, M., Hope, T., Reiter, R., Maurer, T., Weber, W. A., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.198119 · Cited by 626
“In intraprostatic lesions, PSMA-ligand PET has been shown to correlate with tumor aggressiveness as defined by the Gleason score (6,34).”
BackgroundSelf-citationGiesel, F. L., Hadaschik, B., Cardinale, J., Radtke, J., Vinsensia, M., Lehnert, W., Kesch, C., Tolstov, Y., Singer, S., Grabe, N., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3573-4 · Cited by 592
Hofman, M. S., Hicks, R. J., Maurer, T., & Eiber, M. (2018) · RadioGraphics · doi:10.1148/rg.2018170108 · Cited by 383
Seifert, R., Emmett, L., Rowe, S. P., Herrmann, K., Hadaschik, B., Calais, J., Giesel, F. L., Reiter, R., Maurer, T., Heck, M., et al. (2023) · European Urology · doi:10.1016/j.eururo.2023.02.002 · Cited by 313
Self-citationvon Eyben, F. E., Picchio, M., von Eyben, R., Rhee, H., & Bauman, G. (2018) · European Urology Focus · doi:10.1016/j.euf.2016.11.002 · Cited by 257
Hope, T. A., Goodman, J. Z., Allen, I. E., Calais, J., Fendler, W. P., & Carroll, P. R. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.219501 · Cited by 254
Self-citationPSMA Ligands for PET Imaging of Prostate Cancer
Schwarzenboeck, S. M., Rauscher, I., Bluemel, C., Fendler, W. P., Rowe, S. P., Pomper, M. G., Asfhar-Oromieh, A., Herrmann, K., & Eiber, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.191031 · Cited by 215
Self-citationPSMA expression: a potential ally for the pathologist in prostate cancer diagnosis
Bravaccini, S., Puccetti, M., Bocchini, M., Ravaioli, S., Celli, M., Scarpi, E., De Giorgi, U., Tumedei, M. M., Raulli, G., Cardinale, L., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22594-1 · Cited by 189
Comparison of macrocyclic and acyclic chelators for gallium-68 radiolabelling
Tsionou, M. I., Knapp, C. E., Foley, C. A., Munteanu, C. R., Cakebread, A., Imberti, C., Eykyn, T. R., Young, J. D., Paterson, B. M., Blower, P. J., et al. (2017) · RSC Adv. · doi:10.1039/c7ra09076e · Cited by 169
Fendler, W. P., Calais, J., Allen-Auerbach, M., Bluemel, C., Eberhardt, N., Emmett, L., Gupta, P., Hartenbach, M., Hope, T. A., Okamoto, S., et al. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.190827 · Cited by 141
“Image Acquisition and Reconstruction Patient preparation and image acquisition were performed as previously described (8,13).”
BackgroundMethodSelf-citationDerwael, C., Lavergne, O., Lovinfosse, P., Nechifor, V., Salvé, M., Waltregny, D., Hustinx, R., & Withofs, N. (2020) · EJNMMI Research · doi:10.1186/s13550-020-0596-4 · Cited by 23
Metadata
- Authors
- Fendler, W. P., Schmidt, D. F., Wenter, V., Thierfelder, K. M., Zach, C., Stief, C., Bartenstein, P., Kirchner, T., Gildehaus, F. J., Gratzke, C., & Faber, C.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2016-06-03
- Volume
- 57
- Issue
- 11
- Pages
- 1720-1725
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2410782911
- Cited by
- 202
- References
- 16
- FWCI
- 23.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.