Kinetic Modeling of the Tau PET Tracer 18F-AV-1451 in Human Healthy Volunteers and Alzheimer Disease Subjects
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
18F-AV-1451 is currently the most widely used of several experimental tau PET tracers. The objective of this study was to evaluate 18F-AV-1451 binding with full kinetic analysis using a metabolite-corrected arterial input function and to compare parameters derived from kinetic analysis with SUV ratio (SUVR) calculated over different imaging time intervals. Methods:18F-AV-1451 PET brain imaging was completed in 16 subjects: 4 young healthy volunteers (YHV), 4 aged healthy volunteers (AHV), and 8 Alzheimer disease (AD) subjects. Subjects were imaged for 3.5 h, with arterial blood samples obtained throughout. PET data were analyzed using plasma and reference tissue–based methods to estimate the distribution volume, binding potential (BPND), and SUVR. BPND and SUVR were calculated using the cerebellar cortex as a reference region and were compared across the different methods and across the 3 groups (YHV, AHV, and AD). Results: AD demonstrated increased 18F-AV-1451 retention compared with YHV and AHV based on both invasive and noninvasive analyses in cortical regions in which paired helical filament tau accumulation is expected in AD. A correlation of R2 > 0.93 was found between BPND (130 min) and SUVR-1 at all time intervals. Cortical SUVR curves reached a relative plateau around 1.0–1.2 for YHV and AHV by approximately 50 min, but increased in AD by up to approximately 20% at 110–130 min and approximately 30% at 160–180 min relative to 80–100 min. Distribution volume (130 min) was lower by 30%–35% in the YHV than AHV. Conclusion: Our data suggest that although 18F-AV-1451 SUVR curves do not reach a plateau and are still increasing in AD, an SUVR calculated over an imaging window of 80–100 min (as currently used in clinical studies) provides estimates of paired helical filament tau burden in good correlation with BPND, whereas SUVR sensitivity to regional cerebral blood changes needs further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuropathological stageing of Alzheimer-related changes.
Braak, H., & Braak, E. (1991) · Acta Neuropathologica · doi:10.1007/bf00308809 · Cited by 16,123
Consensus Nomenclature for in vivo Imaging of Reversibly Binding Radioligands
Innis, R. B., Cunningham, V. J., Delforge, J., Fujita, M., Gjedde, A., Gunn, R. N., Holden, J., Houle, S., Huang, S.-C., Ichise, M., et al. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600493 · Cited by 1,955 · cited 1×
“The standard 2-tissue-compartment model (2T), 1-tissuecompartment model (1T), and Logan graphical analysis (LGA; t* 5 80 min) plasma-based methods were used with the radiometabolite-corrected arterial plasma input function to estimate distribution volume (VT) in specific brain regions (20,21).”
MethodSelf-citationMaruyama, M., Shimada, H., Suhara, T., Shinotoh, H., Ji, B., Maeda, J., Zhang, M.-R., Trojanowski, J. Q., Lee, V. M.-Y., Ono, M., et al. (2013) · Neuron · doi:10.1016/j.neuron.2013.07.037 · Cited by 760
Early clinical PET imaging results with the novel PHF-tau radioligand [F-18]-T807
Chien, D. T., Bahri, S., Szardenings, A. K., Walsh, J. C., Mu, F., Su, M.-Y., Shankle, W. R., Elizarov, A., & Kolb, H. C. (2013) · Journal of Alzheimer's Disease · doi:10.3233/jad-122059 · Cited by 651 · cited 2×
“Early clinical evaluation has demonstrated heterogeneous and asymmetric brain uptake of the radiotracer (2) consistent with the earlier reports by Braak and Braak (1) showing distribution of tau that follows discrete patterns in cross-sectional postmortem analyses generally correlating with AD severity.”
BackgroundMarquié, M., Normandin, M. D., Vanderburg, C. R., Costantino, I. M., Bien, E. A., Rycyna, L. G., Klunk, W. E., Mathis, C. A., Ikonomovic, M. D., Debnath, M. L., et al. (2015) · Annals of Neurology · doi:10.1002/ana.24517 · Cited by 615
[ 18 F]T807, a novel tau positron emission tomography imaging agent for Alzheimer's disease
Xia, C., Arteaga, J., Chen, G., Gangadharmath, U., Gomez, L. F., Kasi, D., Lam, C., Liang, Q., Liu, C., Mocharla, V. P., et al. (2013) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2012.11.008 · Cited by 605 · cited 1×
“18F-AV-1451 (18F-T807, flortaucipir) (2) is a PET radiotracer with high affinity and specificity for tau aggregates, while lacking affinity for concomitant amyloid-b plaques in human AD (3,4).”
Background18F-THK5351: A Novel PET Radiotracer for Imaging Neurofibrillary Pathology in Alzheimer Disease
Harada, R., Okamura, N., Furumoto, S., Furukawa, K., Ishiki, A., Tomita, N., Tago, T., Hiraoka, K., Watanuki, S., Shidahara, M., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.164848 · Cited by 330 · cited 1×
“Several additional PET agents have been proposed for the imaging of tau in the brain, in particular 11C-PBB3 (5,6), 18FTHK-5117 (7), 18F-T808 (8), 18F-PI-2014 (9), and more recently 11C-RO6924963, 11C-RO6931643, 18F-RO6958948 (10), 18F-THK5351 (11), 18F-GTP1 (12), and 18F-MK6240 (13), and have been or are being charac…”
Background
Cited by
Tau PET imaging: present and future directions
Saint-Aubert, L., Lemoine, L., Chiotis, K., Leuzy, A., Rodriguez-Vieitez, E., & Nordberg, A. (2017) · Molecular Neurodegeneration · doi:10.1186/s13024-017-0162-3 · Cited by 282
Schöll, M., Maass, A., Mattsson, N., Ashton, N. J., Blennow, K., Zetterberg, H., & Jagust, W. (2019) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2018.12.001 · Cited by 229
Baker, S. L., Harrison, T. M., Maass, A., La Joie, R., & Jagust, W. J. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.224113 · Cited by 132
“However, it has also been shown that the distribution volume calculated from arterial input function correlates with age (with different slopes) both in the cerebellum and in cortical regions (15).”
BackgroundLessons learned about [F-18]-AV-1451 off-target binding from an autopsy-confirmed Parkinson’s case.
Marquié, M., Verwer, E. E., Meltzer, A. C., Kim, S. J. W., Agüero, C., Gonzalez, J., Makaretz, S. J., Siao Tick Chong, M., Ramanan, P., Amaral, A. C., et al. (2017) · Acta Neuropathologica Communications · doi:10.1186/s40478-017-0482-0 · Cited by 128
“Interestingly, several [F-18]-AV-1451 kinetic modeling studies [1, 2, 43, 50] have suggested that this tracer has a different kinetic profile in the putamen, with a higher initial uptake and much faster clearance in this region compared to the cortex, and enhanced retention with increasing age.”
Head-to-head comparison of tau positron emission tomography tracers [18F]flortaucipir and [18F]RO948
Smith, R., Schöll, M., Leuzy, A., Jögi, J., Ohlsson, T., Strandberg, O., & Hansson, O. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04496-0 · Cited by 88
Metadata
- Authors
- Barret, O., Alagille, D., Sanabria, S., Comley, R. A., Weimer, R. M., Borroni, E., Mintun, M., Seneca, N., Papin, C., Morley, T., Marek, K., Seibyl, J. P., Tamagnan, G. D., & Jennings, D.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2016-12-01
- Volume
- 58
- Issue
- 7
- Pages
- 1124-1131
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2559092651
- Cited by
- 73
- References
- 7
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.