The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Sensitivity Comparison of 68Ga-OPS202 and 68Ga-DOTATOC PET/CT in Patients with Gastroenteropancreatic Neuroendocrine Tumors: A Prospective Phase II Imaging Study
Open accessAbstract
Radiolabeled somatostatin (sst) receptor agonists are integral to the diagnosis of gastroenteropancreatic neuroendocrine tumors (NETs), but detection rates, especially of liver metastases, remain limited even with PET/CT. 68Ga-OPS202 (68Ga-NODAGA-JR11; NODAGA = 1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid and JR11 = Cpa-c(dCys-Aph(Hor)-dAph(Cbm)-Lys-Thr-Cys)-dTyr-NH2)), a novel radiolabeled sst receptor antagonist with a high affinity for the sst2 receptor, has the potential to perform better than sst receptor agonists. Here, we present the results of the phase II component of a phase I/II study that evaluated the sensitivity of 68Ga-OPS202, compared with the reference compound, 68Ga-DOTATOC (an sst receptor agonist), in PET imaging. Methods: Patients received a single 150-MBq intravenous injection of 68Ga-DOTATOC (15 μg of peptide) and 2 single 150-MBq intravenous injections of 68Ga-OPS202 (15 μg of peptide at visit 1 and 50 μg at visit 2). Whole-body PET/CT acquisitions were performed 1 h after injection on the same calibrated PET/CT scanner. Diagnostic efficacy measures were compared against contrast medium–enhanced CT or MRI as the gold standard. Two independent masked experts read the scans, and both outcomes were combined for analysis. Results: Twelve consecutive patients with low- or intermediate-grade gastroenteropancreatic NETs took part in this prospective study. Image contrast for matched malignant liver lesions was significantly higher for the 68Ga-OPS202 scans than for the 68Ga-DOTATOC scan: the median of the mean tumor-to-background SUVmax ratios were significantly higher for 15 and 50 μg of 68Ga-OPS202 (5.3 and 4.3, with interquartile ranges of 2.9–5.7 and 3.4–6.3 and P values of 0.004 and 0.008) than for 68Ga-DOTATOC (1.9, with an interquartile range of 1.4–2.9). The higher tumor-to-background ratio of 68Ga-OPS202 resulted not only in a higher detection rate of liver metastases but also in a significantly higher lesion-based overall sensitivity with the antagonist than with 68Ga-DOTATOC: 94% and 88% for 50 and 15 μg of 68Ga-OPS202, respectively, and 59% for 15 μg of 68Ga-DOTATOC (P < 0.001). Positive predictive values for 68Ga-OPS202 PET/CT and 68Ga-DOTATOC PET/CT were similar (∼98%). There were no significant differences in image contrast, sensitivity, or positive predictive values between the 2 68Ga-OPS202 peptide doses, indicating a high reproducibility. Conclusion: Preliminary diagnostic efficacy data from this phase II study indicate that 68Ga-OPS202 has high sensitivity for the detection of gastroenteropancreatic NETs. Further studies in larger patient populations are warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reubi, J. C., Schär, J.-C., Waser, B., Wenger, S., Heppeler, A., Schmitt, J. S., & Mäcke, H. R. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050034 · Cited by 1,127
Somatostatin receptor antagonists for imaging and therapy.
Fani, M., Nicolas, G. P., & Wild, D. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186783 · Cited by 274
Unexpected Sensitivity of sst2 Antagonists to N-Terminal Radiometal Modifications
Fani, M., Braun, F., Waser, B., Beetschen, K., Cescato, R., Erchegyi, J., Rivier, J. E., Weber, W. A., Maecke, H. R., & Reubi, J. C. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.102764 · Cited by 172
Self-citation
Cited by
Radioactive Main Group and Rare Earth Metals for Imaging and Therapy
Kostelnik, T. I., & Orvig, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00294 · Cited by 483
Future of Theranostics: An Outlook on Precision Oncology in Nuclear Medicine
Langbein, T., Weber, W. A., & Eiber, M. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.220566 · Cited by 269
Günther, T., Tulipano, G., Dournaud, P., Bousquet, C., Csaba, Z., Kreienkamp, H.-J., Lupp, A., Korbonits, M., Castaño, J. P., Wester, H.-J., et al. (2018) · Pharmacological Reviews · doi:10.1124/pr.117.015388 · Cited by 253
Baum, R. P., Zhang, J., Schuchardt, C., Müller, D., & Mäcke, H. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.258889 · Cited by 127
Reidy-Lagunes, D., Pandit-Taskar, N., O'Donoghue, J. A., Krebs, S., Staton, K. D., Lyashchenko, S. K., Lewis, J. S., Raj, N., Gönen, M., Lohrmann, C., et al. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-1026 · Cited by 112
Metadata
- Authors
- Nicolas, G. P., Schreiter, N., Kaul, F., Uiters, J., Bouterfa, H., Kaufmann, J., Erlanger, T. E., Cathomas, R., Christ, E., Fani, M., & Wild, D.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2017-11-30
- Volume
- 59
- Issue
- 6
- Pages
- 915-921
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2774142960
- Cited by
- 171
- References
- 3
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity Comparison of 68Ga-OPS202 and 68Ga-DOTATOC PET/CT in Patients with Gastroenteropancreatic Neuroendocrine Tumors: A Prospective Phase II Imaging Study. https://app.cochat.ai/papers/10.2967/jnumed.117.199760
- The paper
- Nicolas, G. P., Schreiter, N., Kaul, F., Uiters, J., Bouterfa, H., Kaufmann, J., Erlanger, T. E., Cathomas, R., Christ, E., Fani, M., & Wild, D. (2018). Sensitivity Comparison of 68Ga-OPS202 and 68Ga-DOTATOC PET/CT in Patients with Gastroenteropancreatic Neuroendocrine Tumors: A Prospective Phase II Imaging Study. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.117.199760
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.