Validation of Noninvasive Tracer Kinetic Analysis of 18F-Florbetaben PET Using a Dual–Time-Window Acquisition Protocol
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Accurate amyloid PET quantification is necessary for monitoring amyloid-β accumulation and response to therapy. Currently, most of the studies are analyzed using the static SUV ratio (SUVR) approach because of its simplicity. However, this approach may be influenced by changes in cerebral blood flow (CBF) or radiotracer clearance. Full tracer kinetic models require arterial blood sampling and dynamic image acquisition. The objectives of this work were, first, to validate a noninvasive kinetic modeling approach for 18F-florbetaben PET using an acquisition protocol with the best compromise between quantification accuracy and simplicity and, second, to assess the impact of CBF changes and radiotracer clearance on SUVRs and noninvasive kinetic modeling data in 18F-florbetaben PET. Methods: Using data from 20 subjects (10 patients with probable Alzheimer dementia and 10 healthy volunteers), the nondisplaceable binding potential (BPND) obtained from the full kinetic analysis was compared with the SUVR and with noninvasive tracer kinetic methods (simplified reference tissue model and multilinear reference tissue model 2). Various approaches using shortened or interrupted acquisitions were compared with the results of the full acquisition (0–140 min). Simulations were performed to assess the effect of CBF and radiotracer clearance changes on SUVRs and noninvasive kinetic modeling outputs. Results: An acquisition protocol using time windows of 0–30 and 120–140 min with appropriate interpolation of the missing time points provided the best compromise between patient comfort and quantification accuracy. Excellent agreement was found between BPND obtained using the full protocol and BPND obtained using the dual-window protocol (for multilinear reference tissue model 2, BPND [dual-window] = 0.01 + 1.00·BPND [full], R2 = 0.97; for simplified reference tissue model, BPND [dual-window] = 0.05 + 0.92·BPND [full], R2 = 0.93). Simulations showed a limited impact of CBF and radiotracer clearance changes on multilinear reference tissue model parameters and SUVR. Conclusion: This study demonstrated accurate noninvasive kinetic modeling of 18F-florbetaben PET data using a dual-window acquisition, thus providing a good compromise between quantification accuracy, scan duration, and patient burden. The influence of CBF and radiotracer clearance changes on amyloid-β load estimates was small. For most clinical research applications, the SUVR approach is appropriate. However, for longitudinal studies in which maximum quantification accuracy is desired, this noninvasive dual-window acquisition with kinetic analysis is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Florbetaben PET imaging to detect amyloid beta plaques in Alzheimer's disease: Phase 3 study
Sabri, O., Sabbagh, M. N., Seibyl, J., Barthel, H., Akatsu, H., Ouchi, Y., Senda, K., Murayama, S., Ishii, K., Takao, M., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2015.02.004 · Cited by 602 · cited 1×
“Previous work has demonstrated that 18Fflorbetaben SUVR correlates strongly with the presence of amyloid-b as confirmed by histopathology (3) and with the outcomes from tracer kinetic modeling using arterial blood sampling (4).”
BackgroundSelf-citationEvaluation of early-phase [18F]-florbetaben PET acquisition in clinical routine cases
Daerr, S., Brendel, M., Zach, C., Mille, E., Schilling, D., Zacherl, M. J., Bürger, K., Danek, A., Pogarell, O., Schildan, A., et al. (2017) · NeuroImage: Clinical · doi:10.1016/j.nicl.2016.10.005 · Cited by 124
Self-citation
Cited by
β-Amyloid accumulation in the human brain after one night of sleep deprivation
Shokri-Kojori, E., Wang, G.-J., Wiers, C. E., Demiral, S. B., Guo, M., Kim, S. W., Lindgren, E., Ramirez, V., Zehra, A., Freeman, C., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1721694115 · Cited by 893
Quantification of amyloid PET for future clinical use: a state-of-the-art review
Pemberton, H. G., Collij, L. E., Heeman, F., Bollack, A., Shekari, M., Salvadó, G., Alves, I. L., Garcia, D. V., Battle, M., Buckley, C., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05784-y · Cited by 226
“A key area of current research focusses on the potential sensitivity of visual assessment and quantification methods to variation in scanners [101], reconstruction algorithms [102–104], scanning time, and scanning window [93, 105, 106], all of which can affect both visual assessment and quantification.”
BackgroundSelf-citationMeng, Y., Goubran, M., Rabin, J. S., McSweeney, M., Ottoy, J., Pople, C. B., Huang, Y., Storace, A., Ozzoude, M., Bethune, A., et al. (2023) · Brain · doi:10.1093/brain/awac459 · Cited by 83
Early detection of amyloid load using 18F-florbetaben PET
Bullich, S., Roé-Vellvé, N., Marquié, M., Landau, S. M., Barthel, H., Villemagne, V. L., Sanabria, Á., Tartari, J. P., Sotolongo-Grau, O., Doré, V., et al. (2021) · Alzheimer's Research & Therapy · doi:10.1186/s13195-021-00807-6 · Cited by 71
Self-citation
Metadata
- Authors
- Bullich, S., Barthel, H., Koglin, N., Becker, G. A., De Santi, S., Jovalekic, A., Stephens, A. W., & Sabri, O.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2017-11-24
- Volume
- 59
- Issue
- 7
- Pages
- 1104-1110
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2769234458
- Cited by
- 42
- References
- 2
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Noninvasive Tracer Kinetic Analysis of 18F-Florbetaben PET Using a Dual–Time-Window Acquisition Protocol. https://app.cochat.ai/papers/10.2967/jnumed.117.200964
- The paper
- Bullich, S., Barthel, H., Koglin, N., Becker, G. A., De Santi, S., Jovalekic, A., Stephens, A. W., & Sabri, O. (2018). Validation of Noninvasive Tracer Kinetic Analysis of 18F-Florbetaben PET Using a Dual–Time-Window Acquisition Protocol. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.117.200964
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.