68Ga-FAPI PET/CT: Biodistribution and Preliminary Dosimetry Estimate of 2 DOTA-Containing FAP-Targeting Agents in Patients with Various Cancers
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Fibroblast activation protein (FAP) is overexpressed in cancer-associated fibroblasts of several tumor entities. The recent development of quinoline-based PET tracers that act as FAP inhibitors (FAPIs) demonstrated promising results preclinically and already in a few clinical cases. Consequently, these tracers are now applied in our hospital to amend the diagnostics of cancer patients facing the limitations of standard examinations. Here, we analyze the tissue biodistribution and preliminary dosimetry of 2 members of this new class of PET radiopharmaceutical. Methods: A preliminary dosimetry estimate for 68Ga-FAPI-2 and 68Ga-FAPI-4 was based on 2 patients examined at 0.2, 1, and 3 h after tracer injection using the QDOSE dosimetry software suit. Further PET/CT scans of tumor patients were acquired 1 h after injection of either 68Ga-FAPI-2 (n = 25) or 68Ga-FAPI-4 (n = 25); for 6 patients an intraindividual related 18F-FDG scan (also acquired 1 h after injection) was available. For the normal tissue of 16 organs, a 2-cm spheric volume of interest was placed in the parenchyma; for tumor lesions, a threshold-segmented volume of interest was used to quantify SUVmean and SUVmax. Results: Similar to literature values for 18F-FDG, 68Ga-DOTATATE, and 68Ga-PSMA-11, an examination with 200 MBq of 68Ga-FAPI-2 or 68Ga-FAPI-4 corresponds to an equivalent dose of approximately 3–4 mSv. After a fast clearance via the kidneys, the normal organs showed a low tracer uptake with only minimal changes between 10 min and 3 h after injection. In 68Ga-FAPI-2, the tumor uptake from 1 to 3 h after injection decreased by 75%, whereas the tumor retention was prolonged with 68Ga-FAPI-4 (25% washout). Regarding tumor-to-background ratios, at 1 h after injection both 68Ga-FAPI tracers performed equally. In comparison to 18F-FDG, the tumor uptake was almost equal (average SUVmax, 7.41 for 18F-FDG and 7.37 for 68Ga-FAPI-2; not statistically significant); the background uptake in brain (11.01 vs. 0.32), liver (2.77 vs. 1.69), and oral/pharyngeal mucosa (4.88 vs. 2.57) was significantly lower with 68Ga-FAPI. Other organs did not relevantly differ between 18F-FDG and 68Ga-FAPI. Conclusion: FAPI PET/CT is a new diagnostic method in imaging cancer patients. In contrast to 18F-FDG, no diet or fasting in preparation for the examination is necessary, and image acquisition can potentially be started a few minutes after tracer application. Tumor-to-background contrast ratios were equal to or even better than those of 18F-FDG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase 3 Trial of 177 Lu-Dotatate for Midgut Neuroendocrine Tumors
Strosberg, J., El-Haddad, G., Wolin, E., Hendifar, A., Yao, J., Chasen, B., Mittra, E., Kunz, P. L., Kulke, M. H., Jacene, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1607427 · Cited by 3,308
Stabin, M. G., Sparks, R. B., & Crowe, E. A. (2005) · PubMed · Cited by 1,350
Hofman, M. S., Violet, J., Hicks, R. J., Ferdinandus, J., Thang, S. P., Akhurst, T., Iravani, A., Kong, G., Ravi Kumar, A., Murphy, D. G., et al. (2018) · The Lancet Oncology · doi:10.1016/s1470-2045(18)30198-0 · Cited by 1,174
Lindner, T., Loktev, A., Altmann, A., Giesel, F., Kratochwil, C., Debus, J., Jäger, D., Mier, W., & Haberkorn, U. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.210443 · Cited by 935
Self-citationA Tumor-Imaging Method Targeting Cancer-Associated Fibroblasts
Loktev, A., Lindner, T., Mier, W., Debus, J., Altmann, A., Jäger, D., Giesel, F., Kratochwil, C., Barthe, P., Roumestand, C., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.210435 · Cited by 777
Self-citationSpecific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Realistic reference phantoms: An ICRP/ICRU joint effort
(2009) · Annals of the ICRP · doi:10.1016/j.icrp.2009.09.001 · Cited by 496
Hamson, E. J., Keane, F. M., Tholen, S., Schilling, O., & Gorrell, M. D. (2014) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201300095 · Cited by 496
Specific absorbed fractions of energy at various ages from internal photon sources: 1, Methods
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6233735 · Cited by 310
EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry
Hindorf, C., Glatting, G., Chiesa, C., Lindén, O., & Flux, G. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1422-4 · Cited by 297
Jansen, K., Heirbaut, L., Cheng, J. D., Joossens, J., Ryabtsova, O., Cos, P., Maes, L., Lambeir, A.-M., De Meester, I., Augustyns, K., et al. (2013) · ACS Medicinal Chemistry Letters · doi:10.1021/ml300410d · Cited by 260
Tillmanns, J., Hoffmann, D., Habbaba, Y., Schmitto, J. D., Sedding, D., Fraccarollo, D., Galuppo, P., & Bauersachs, J. (2015) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2015.08.016 · Cited by 237
Andersson, M., Johansson, L., Eckerman, K., & Mattsson, S. (2017) · EJNMMI Research · doi:10.1186/s13550-017-0339-3 · Cited by 230
Radiation dosimetry of 68Ga-PSMA-11 (HBED-CC) and preliminary evaluation of optimal imaging timing
Afshar-Oromieh, A., Hetzheim, H., Kübler, W., Kratochwil, C., Giesel, F. L., Hope, T. A., Eder, M., Eisenhut, M., Kopka, K., & Haberkorn, U. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3419-0 · Cited by 185
Self-citationBolch, W. E., Jokisch, D., Zankl, M., Eckerman, K. F., Fell, T., Manger, R., Endo, A., Hunt, J., Kim, K. P., & Petoussi-Henss, N. (2016) · Annals of the ICRP · doi:10.1177/0146645316661077 · Cited by 176
Sandström, M., Velikyan, I., Garske-Román, U., Sörensen, J., Eriksson, B., Granberg, D., Lundqvist, H., Sundin, A., & Lubberink, M. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.120600 · Cited by 161
Poplawski, S. E., Lai, J. H., Li, Y., Jin, Z., Liu, Y., Wu, W., Wu, Y., Zhou, Y., Sudmeier, J. L., Sanford, D. G., et al. (2013) · Journal of Medicinal Chemistry · doi:10.1021/jm400351a · Cited by 116
Yun, M., Bang, S.-H., Kim, J. W., Park, J. Y., Kim, K. S., & Lee, J. D. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.062703 · Cited by 109
Egger, C., Cannet, C., Gérard, C., Suply, T., Ksiazek, I., Jarman, E., & Beckmann, N. (2017) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2017.05.022 · Cited by 92
Pfob, C. H., Ziegler, S. I., Graner, F. P., Köhner, M., Schachoff, S., Blechert, B., Wester, H., Scheidhauer, K., Schwaiger, M., Maurer, T., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3424-3 · Cited by 87
FDG-PET is not useful in early pancreatic cancer diagnosis
Strobel, O., & Büchler, M. W. (2013) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2013.42 · Cited by 52
Increased N‐terminal cleavage of alpha‐2‐antiplasmin in patients with liver cirrhosis
de Willige, S. U., Malfliet, J. J. M. C., Janssen, H. L. A., Leebeek, F. W. G., & Rijken, D. C. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12396 · Cited by 45
Cited by
68Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer
Kratochwil, C., Flechsig, P., Lindner, T., Abderrahim, L., Altmann, A., Mier, W., Adeberg, S., Rathke, H., Röhrich, M., Winter, H., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.227967 · Cited by 1,464
Self-citationDevelopment of Fibroblast Activation Protein–Targeted Radiotracers with Improved Tumor Retention
Loktev, A., Lindner, T., Burger, E.-M., Altmann, A., Giesel, F., Kratochwil, C., Debus, J., Marmé, F., Jäger, D., Mier, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.224469 · Cited by 554
Self-citationChen, H., Pang, Y., Wu, J., Zhao, L., Hao, B., Wu, J., Wei, J., Wu, S., Zhao, L., Luo, Z., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04769-z · Cited by 545
ImmunoPET: Concept, Design, and Applications
Wei, W., Rosenkrans, Z. T., Liu, J., Huang, G., Luo, Q.-Y., & Cai, W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00738 · Cited by 484
Watabe, T., Liu, Y., Kaneda-Nakashima, K., Shirakami, Y., Lindner, T., Ooe, K., Toyoshima, A., Nagata, K., Shimosegawa, E., Haberkorn, U., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.233122 · Cited by 302
Self-citation
Metadata
- Authors
- Giesel, F. L., Kratochwil, C., Lindner, T., Marschalek, M. M., Loktev, A., Lehnert, W., Debus, J., Jäger, D., Flechsig, P., Altmann, A., Mier, W., & Haberkorn, U.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2018-08-02
- Volume
- 60
- Issue
- 3
- Pages
- 386-392
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2887241162
- Cited by
- 740
- References
- 22
- FWCI
- 18.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.