Comparative Biodistribution and Radiation Dosimetry of 68Ga-DOTATOC and 68Ga-DOTATATE in Patients with Neuroendocrine Tumors
Open accessAbstract
UNLABELLED: (68)Ga-DOTATOC and (68)Ga-DOTATATE are 2 radiolabeled somatostatin analogs for in vivo diagnosis of neuroendocrine tumors with PET. The aim of the present work was to measure their comparative biodistribution and radiation dosimetry. METHODS: Ten patients diagnosed with neuroendocrine tumors were included. Each patient underwent a 45-min dynamic and 3 whole-body PET/CT scans at 1, 2, and 3 h after injection of each tracer on consecutive days. Absorbed doses were calculated using OLINDA/EXM 1.1. RESULTS: Data from 9 patients could be included in the analysis. Of the major organs, the highest uptake at 1, 2, and 3 h after injection was observed in the spleen, followed by kidneys and liver. For both tracers, the highest absorbed organ doses were seen in the spleen and urinary bladder wall, followed by kidney, adrenals, and liver. The absorbed doses to the liver and gallbladder wall were slightly but significantly higher for (68)Ga-DOTATATE. The total effective dose was 0.021 ± 0.003 mSv/MBq for both tracers. CONCLUSION: The effective dose for a typical 100-MBq administration of (68)Ga-DOTATATE and (68)Ga-DOTATOC is 2.1 mSv for both tracers. Therefore, from a radiation dosimetry point of view, there is no preference for either tracer for PET/CT evaluation of somatostatin receptor-expressing tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Giesel, F. L., Kratochwil, C., Lindner, T., Marschalek, M. M., Loktev, A., Lehnert, W., Debus, J., Jäger, D., Flechsig, P., Altmann, A., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215913 · Cited by 740
Principles in the design of ligand-targeted cancer therapeutics and imaging agents
Srinivasarao, M., Galliford, C. V., & Low, P. S. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4519 · Cited by 671
Hofman, M. S., Lau, W. F. E., & Hicks, R. J. (2015) · RadioGraphics · doi:10.1148/rg.352140164 · Cited by 561
Phase I Study of 68Ga-HER2-Nanobody for PET/CT Assessment of HER2 Expression in Breast Carcinoma
Keyaerts, M., Xavier, C., Heemskerk, J., Devoogdt, N., Everaert, H., Ackaert, C., Vanhoeij, M., Duhoux, F. P., Gevaert, T., Simon, P., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.162024 · Cited by 429
Taïeb, D., Hicks, R. J., Hindié, E., Guillet, B. A., Avram, A., Ghedini, P., Timmers, H. J., Scott, A. T., Elojeimy, S., Rubello, D., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04398-1 · Cited by 403
Metadata
- Authors
- Sandström, M., Velikyan, I., Garske-Román, U., Sörensen, J., Eriksson, B., Granberg, D., Lundqvist, H., Sundin, A., & Lubberink, M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2013-08-08
- Volume
- 54
- Issue
- 10
- Pages
- 1755-1759
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2127304289
- Cited by
- 161
- References
- 0
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative Biodistribution and Radiation Dosimetry of 68Ga-DOTATOC and 68Ga-DOTATATE in Patients with Neuroendocrine Tumors. https://app.cochat.ai/papers/10.2967/jnumed.113.120600
- The paper
- Sandström, M., Velikyan, I., Garske-Román, U., Sörensen, J., Eriksson, B., Granberg, D., Lundqvist, H., Sundin, A., & Lubberink, M. (2013). Comparative Biodistribution and Radiation Dosimetry of 68Ga-DOTATOC and 68Ga-DOTATATE in Patients with Neuroendocrine Tumors. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.113.120600
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.