Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The world’s first 194-cm-long total-body PET/CT scanner (uEXPLORER) has been built by the EXPLORER Consortium to offer a transformative platform for human molecular imaging in clinical research and health care. Its total-body coverage and ultra-high sensitivity provide opportunities for more accurate tracer kinetic analysis in studies of physiology, biochemistry, and pharmacology. The objective of this study was to demonstrate the capability of total-body parametric imaging and to quantify the improvement in image quality and kinetic parameter estimation by direct and kernel reconstruction of the uEXPLORER data. Methods: We developed quantitative parametric image reconstruction methods for kinetic analysis and used them to analyze the first human dynamic total-body PET study. A healthy female subject was recruited, and a 1-h dynamic scan was acquired during and after an intravenous injection of 256 MBq of 18F-FDG. Dynamic data were reconstructed using a 3-dimensional time-of-flight list-mode ordered-subsets expectation maximization (OSEM) algorithm and a kernel-based algorithm with all quantitative corrections implemented in the forward model. The Patlak graphical model was used to analyze the 18F-FDG kinetics in the whole body. The input function was extracted from a region over the descending aorta. For comparison, indirect Patlak analysis from reconstructed frames and direct reconstruction of parametric images from the list-mode data were obtained for the last 30 min of data. Results: Images reconstructed by OSEM showed good quality with low noise, even for the 1-s frames. The image quality was further improved using the kernel method. Total-body Patlak parametric images were obtained using either indirect estimation or direct reconstruction. The direct reconstruction method improved the parametric image quality, having a better contrast-versus-noise tradeoff than the indirect method, with a 2- to 3-fold variance reduction. The kernel-based indirect Patlak method offered image quality similar to the direct Patlak method, with less computation time and faster convergence. Conclusion: This study demonstrated the capability of total-body parametric imaging using the uEXPLORER. Furthermore, the results showed the benefits of kernel-regularized reconstruction and direct parametric reconstruction. Both can achieve superior image quality for tracer kinetic studies compared with the conventional indirect OSEM for total-body imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patlak, C. S., & Blasberg, R. G. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.87 · Cited by 1,673 · cited 2×
“The linear Patlak graphical method was adopted to analyze the 18F-FDG kinetics in different tissues using the last 30 min of data (21).”
MethodPositron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763 · cited 1×
“To overcome the limitation of low sensitivity and short AFOV in current clinical PET scanners, the EXPLORER Consortium has been developing very large AFOV imaging systems to offer a transformative platform for biomedical research and clinical applications (5).”
MethodSelf-citationFirst Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226498 · Cited by 722 · cited 2×
“device built by United Imaging Healthcare, and we use this name to refer to the specific scanner tested in this work) (9).”
BackgroundMethodSelf-citationDynamic whole-body PET imaging: principles, potentials and applications
Rahmim, A., Lodge, M. A., Karakatsanis, N. A., Panin, V. Y., Zhou, Y., McMillan, A., Cho, S., Zaidi, H., Casey, M. E., & Wahl, R. L. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4153-6 · Cited by 273 · cited 1×
“, typically from head or neck to upper thigh), multiple-bed-position scans (step-and-shoot mode or continuous bed motion) with a sequential multipass protocol were introduced (3,4).”
MethodPET Image Reconstruction Using Kernel Method
Wang, G., & Qi, J. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2343916 · Cited by 239
Self-citationTracer Kinetic Modeling in PET
Carson, R. E. (2006) · Positron Emission Tomography · doi:10.1007/1-84628-007-9_6 · Cited by 186 · cited 1×
“, Patlak plot and Logan plot) and compartmental models (12).”
BackgroundDirect Estimation of Kinetic Parametric Images for Dynamic PET
Wang, G., & Qi, J. (2013) · Theranostics · doi:10.7150/thno.5130 · Cited by 136 · cited 1×
“It has been shown that direct reconstruction methods can improve the image quality and SNR of parametric images (18-20).”
BackgroundSelf-citationQuantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner
Zhang, X., Zhou, J., Cherry, S. R., Badawi, R. D., & Qi, J. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5e46 · Cited by 130 · cited 3×
“Quantitative Image Reconstruction and Correction We developed quantitative image reconstruction software for the EXPLORER scanner (24).”
MethodSelf-citationTsoumpas, C., Turkheimer, F., & Thielemans, K. (2008) · Medical Physics · doi:10.1118/1.2885369 · Cited by 116 · cited 1×
“It is easy to implement but usually results in high noise in the parametric images because the noise distribution in reconstructed images is difficult to model (13).”
Background
Cited by
Dimitrakopoulou-Strauss, A., Pan, L., & Sachpekidis, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04843-6 · Cited by 203
“This issue can, however, be addressed with the introduction of clinically feasible dynamic whole-body PET imaging protocols in current generation limited axial FOV PET systems equipped with direct 4D reconstruction schemes and generalized nonlinear graphical analysis methods [8, 10, 107, 108].”
BackgroundPositronium imaging with the novel multiphoton PET scanner
Moskal, P., Dulski, K., Chug, N., Curceanu, C., Czerwiński, E., Dadgar, M., Gajewski, J., Gajos, A., Grudzień, G., Hiesmayr, B. C., et al. (2021) · Science Advances · doi:10.1126/sciadv.abh4394 · Cited by 180
Zhang, Y.-Q., Hu, P.-C., Wu, R.-Z., Gu, Y.-S., Chen, S.-G., Yu, H.-J., Wang, X.-Q., Song, J., & Shi, H.-C. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04823-w · Cited by 123
Self-citation
Metadata
- Authors
- Zhang, X., Xie, Z., Berg, E., Judenhofer, M. S., Liu, W., Xu, T., Ding, Y., Lv, Y., Dong, Y., Deng, Z., Tang, S., Shi, H., Hu, P., Chen, S., Bao, J., Li, H., Zhou, J., Wang, G., Cherry, S. R., Badawi, R. D., & Qi, J.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2019-07-13
- Volume
- 61
- Issue
- 2
- Pages
- 285-291
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2959949113
- Cited by
- 206
- References
- 19
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.