The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Open accessAbstract
Within the EXPLORER Consortium, the construction of the world’s first total-body PET/CT scanner has recently been completed. The 194-cm axial field of view of the EXPLORER PET/CT scanner is sufficient to cover, for the first time, the entire human adult body in a single acquisition in more than 99% of the population and allows total-body pharmacokinetic studies with frame durations as short as 1 s. The large increase in sensitivity arising from total-body coverage as well as increased solid angle for detection at any point within the body allows whole-body 18F-FDG PET studies to be acquired with unprecedented count density, improving the signal-to-noise ratio of the resulting images. Alternatively, the sensitivity gain can be used to acquire diagnostic PET images with very small amounts of activity in the field of view (25 MBq, 0.7 mCi or less), with very short acquisition times (∼1 min or less) or at later time points after the tracer’s administration. We report here on the first human imaging studies on the EXPLORER scanner using a range of different protocols that provide initial evidence in support of these claims. These case studies provide the foundation for future carefully controlled trials to quantitatively evaluate the improvements possible through total-body PET imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
Self-citationRadiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations.
Brix, G., Lechel, U., Glatting, G., Ziegler, S. I., Münzing, W., Müller, S. P., & Beyer, T. (2005) · PubMed · Cited by 458
Total-body imaging: Transforming the role of positron emission tomography
Cherry, S. R., Badawi, R. D., Karp, J. S., Moses, W. W., Price, P., & Jones, T. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6169 · Cited by 251
Self-citationPoon, J. K., Dahlbom, M. L., Moses, W. W., Balakrishnan, K., Wang, W., Cherry, S. R., & Badawi, R. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/13/4077 · Cited by 129
Self-citationAyati, N., Lee, S. T., Zakavi, S. R., Pathmaraj, K., Al-Qatawna, L., Poon, A. M. T., & Scott, A. M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.192203 · Cited by 61
Lv, Y., Lv, X., Liu, W., Judenhofer, M. S., Zwingenberger, A. L., Wisner, E. R., Berg, E., McKenney, S. E., Leung, E. K., Spencer, B. A., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aafc6c · Cited by 50
Self-citation
Cited by
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
Self-citationAdvances in PET imaging of cancer
Schwenck, J., Sonanini, D., Cotton, J. M., Rammensee, H.-G., la Fougère, C., Zender, L., & Pichler, B. J. (2023) · Nature Reviews Cancer · doi:10.1038/s41568-023-00576-4 · Cited by 312
Radiolabelling of nanomaterials for medical imaging and therapy
Pellico, J., Gawne, P. J., & T. M. de Rosales, R. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00384k · Cited by 304
Roadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Zhang, Y.-Q., Hu, P.-C., Wu, R.-Z., Gu, Y.-S., Chen, S.-G., Yu, H.-J., Wang, X.-Q., Song, J., & Shi, H.-C. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04823-w · Cited by 123
Self-citation
Metadata
- Authors
- Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., Bao, J., Jones, T., Li, H., & Cherry, S. R.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2019-02-07
- Volume
- 60
- Issue
- 3
- Pages
- 299-303
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2914020168
- Cited by
- 722
- References
- 6
- FWCI
- 55.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*. https://app.cochat.ai/papers/10.2967/jnumed.119.226498
- The paper
- Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., Bao, J., Jones, T., Li, H., & Cherry, S. R. (2019). First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.119.226498
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.