PennPET Explorer: Human Imaging on a Whole-Body Imager
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The PennPET Explorer, a prototype whole-body imager currently operating with a 64-cm axial field of view, can image the major body organs simultaneously with higher sensitivity than that of commercial devices. We report here the initial human imaging studies on the PennPET Explorer, with each study designed to test specific capabilities of the device. Methods: Healthy subjects were imaged with FDG on the PennPET Explorer. Subsequently, clinical subjects with disease were imaged with 18F-FDG and 68Ga-DOTATATE, and research subjects were imaged with experimental radiotracers. Results: We demonstrated the ability to scan for a shorter duration or, alternatively, with less activity, without a compromise in image quality. Delayed images, up to 10 half-lives with 18F-FDG, revealed biologic insight and supported the ability to track biologic processes over time. In a clinical subject, the PennPET Explorer better delineated the extent of 18F-FDG–avid disease. In a second clinical study with 68Ga-DOTATATE, we demonstrated comparable diagnostic image quality between the PennPET scan and the clinical scan, but with one fifth the activity. Dynamic imaging studies captured relatively noise-free input functions for kinetic modeling approaches. Additional studies with experimental research radiotracers illustrated the benefits from the combination of large axial coverage and high sensitivity. Conclusion: These studies provided a proof of concept for many proposed applications for a PET scanner with a long axial field of view.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763 · cited 3×
“These expanded capabilities have both research and direct clinical applications (4,5).”
BackgroundMethodSelf-citationFirst Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226498 · Cited by 722 · cited 1×
“The first human studies of the former system have been previously published (8).”
BackgroundThe digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317 · cited 1×
“Philips Digital Photon Counting (PDPC) (11) with 1:1 crystal coupling, high count rate capability”
BackgroundGambhir, S. S., Schwaiger, M., Huang, S., Krivokapich, J., Schelbert, H. R., Nienaber, C. A., & Phelps, M. E. (1989) · PubMed · Cited by 268
Image-Derived Input Function for Brain PET Studies: Many Challenges and Few Opportunities
Zanotti-Fregonara, P., Chen, K., Liow, J.-S., Fujita, M., & Innis, R. B. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.107 · Cited by 263 · cited 1×
“Having the left ventricle always within the FOV provides a validated image-derived input function (23), possibly obviating sophisticated correction techniques (24) or direct arterial sampling.”
BackgroundAdvantage of delayed whole-body FDG-PET imaging for tumour detection
Kubota, K., Itoh, M., Ozaki, K., Ono, S., Tashiro, M., Yamaguchi, K., Akaizawa, T., Yamada, K., & Fukuda, H. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100537 · Cited by 263 · cited 1×
“The sensitivity with which lesions are detected may consequently improve (21).”
BackgroundTotal-body imaging: Transforming the role of positron emission tomography
Cherry, S. R., Badawi, R. D., Karp, J. S., Moses, W. W., Price, P., & Jones, T. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6169 · Cited by 251 · cited 3×
“These expanded capabilities have both research and direct clinical applications (4,5).”
BackgroundMethodSelf-citationPediatric Radiopharmaceutical Administered Doses: 2010 North American Consensus Guidelines
Gelfand, M. J., Parisi, M. T., & Treves, S. T. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.084327 · Cited by 245 · cited 1×
“Images with lower activity may prove beneficial for pediatric patients (18), as well as for radiotracers of limited supply, including those for research and clinical care.”
BackgroundStudies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System
Hsu, D. F. C., Ilan, E., Peterson, W. T., Uribe, J., Lubberink, M., & Levin, C. S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.189514 · Cited by 241
PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager
Karp, J. S., Viswanath, V., Geagan, M. J., Muehllehner, G., Pantel, A. R., Parma, M. J., Perkins, A. E., Schmall, J. P., Werner, M. E., & Daube-Witherspoon, M. E. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.229997 · Cited by 198 · cited 4×
“As part of this effort, we have developed the PennPET Explorer, a whole-body PET imager (6).”
BackgroundMethodSelf-citation
Cited by
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
“The EXPLORER consortium also supported development of the PennPET EXPLORER, a prototype PET scanner with a 64-cm AFOV (11,12) Received Jun.”
MethodDimitrakopoulou-Strauss, A., Pan, L., & Sachpekidis, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04843-6 · Cited by 203
“This issue can, however, be addressed with the introduction of clinically feasible dynamic whole-body PET imaging protocols in current generation limited axial FOV PET systems equipped with direct 4D reconstruction schemes and generalized nonlinear graphical analysis methods [8, 10, 107, 108].”
BackgroundZhang, Y.-Q., Hu, P.-C., Wu, R.-Z., Gu, Y.-S., Chen, S.-G., Yu, H.-J., Wang, X.-Q., Song, J., & Shi, H.-C. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04823-w · Cited by 123
Positron emission tomography in multiple sclerosis - straight to the target
Bodini, B., Tonietto, M., Airas, L., & Stankoff, B. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-021-00537-1 · Cited by 74
Metadata
- Authors
- Pantel, A. R., Viswanath, V., Daube-Witherspoon, M. E., Dubroff, J. G., Muehllehner, G., Parma, M. J., Pryma, D. A., Schubert, E. K., Mankoff, D. A., & Karp, J. S.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2019-09-27
- Volume
- 61
- Issue
- 1
- Pages
- 144-151
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2976839768
- Cited by
- 179
- References
- 19
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PennPET Explorer: Human Imaging on a Whole-Body Imager. https://app.cochat.ai/papers/10.2967/jnumed.119.231845
- The paper
- Pantel, A. R., Viswanath, V., Daube-Witherspoon, M. E., Dubroff, J. G., Muehllehner, G., Parma, M. J., Pryma, D. A., Schubert, E. K., Mankoff, D. A., & Karp, J. S. (2020). PennPET Explorer: Human Imaging on a Whole-Body Imager. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.119.231845
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.