Fully Automated, Semantic Segmentation of Whole-Body18F-FDG PET/CT Images Based on Data-Centric Artificial Intelligence
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We introduce multiple-organ objective segmentation (MOOSE) software that generates subject-specific, multiorgan segmentation using data-centric artificial intelligence principles to facilitate high-throughput systemic investigations of the human body via whole-body PET imaging. Methods: Image data from 2 PET/CT systems were used in training MOOSE. For noncerebral structures, 50 whole-body CT images were used, 30 of which were acquired from healthy controls (14 men and 16 women), and 20 datasets were acquired from oncology patients (14 men and 6 women). Noncerebral tissues consisted of 13 abdominal organs, 20 bone segments, subcutaneous fat, visceral fat, psoas muscle, and skeletal muscle. An expert panel manually segmented all noncerebral structures except for subcutaneous fat, visceral fat, and skeletal muscle, which were semiautomatically segmented using thresholding. A majority-voting algorithm was used to generate a reference-standard segmentation. From the 50 CT datasets, 40 were used for training and 10 for testing. For cerebral structures, 34 18F-FDG PET/MRI brain image volumes were used from 10 healthy controls (5 men and 5 women imaged twice) and 14 nonlesional epilepsy patients (7 men and 7 women). Only 18F-FDG PET images were considered for training: 24 and 10 of 34 volumes were used for training and testing, respectively. The Dice score coefficient (DSC) was used as the primary metric, and the average symmetric surface distance as a secondary metric, to evaluate the automated segmentation performance. Results: An excellent overlap between the reference labels and MOOSE-derived organ segmentations was observed: 92% of noncerebral tissues showed DSCs of more than 0.90, whereas a few organs exhibited lower DSCs (e.g., adrenal glands [0.72], pancreas [0.85], and bladder [0.86]). The median DSCs of brain subregions derived from PET images were lower. Only 29% of the brain segments had a median DSC of more than 0.90, whereas segmentation of 60% of regions yielded a median DSC of 0.80–0.89. The results of the average symmetric surface distance analysis demonstrated that the average distance between the reference standard and the automatically segmented tissue surfaces (organs, bones, and brain regions) lies within the size of image voxels (2 mm). Conclusion: The proposed segmentation pipeline allows automatic segmentation of 120 unique tissues from whole-body 18F-FDG PET/CT images with high accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021) · Nature Methods · doi:10.1038/s41592-020-01008-z · Cited by 10,477
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Extrapulmonary manifestations of COVID-19
Gupta, A., Madhavan, M. V., Sehgal, K., Nair, N., Mahajan, S., Sehrawat, T. S., Bikdeli, B., Ahluwalia, N., Ausiello, J. C., Wan, E. Y., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0968-3 · Cited by 3,185 · cited 1×
“Such systemic analysis might allow the investigation of multiorgan interactions in various pathologies, such as those associated with cancer ( 9 ), cachexia ( 10,11 ), metabolic syndrome ( 12 ), or the more recent severe acute respiratory syndrome coronavirus 2 ( 13 ).”
BackgroundWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
Self-citationAutomated Abdominal Segmentation of CT Scans for Body Composition Analysis Using Deep Learning
Weston, A. D., Korfiatis, P., Kline, T. L., Philbrick, K. A., Kostandy, P., Sakinis, T., Sugimoto, M., Takahashi, N., & Erickson, B. J. (2019) · Radiology · doi:10.1148/radiol.2018181432 · Cited by 358
Inter-organ cross-talk in metabolic syndrome
Priest, C., & Tontonoz, P. (2019) · Nature Metabolism · doi:10.1038/s42255-019-0145-5 · Cited by 279 · cited 1×
“Such systemic analysis might allow the investigation of multiorgan interactions in various pathologies, such as those associated with cancer ( 9 ), cachexia ( 10,11 ), metabolic syndrome ( 12 ), or the more recent severe acute respiratory syndrome coronavirus 2 ( 13 ).”
Background
Cited by
TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images
Wasserthal, J., Breit, H.-C., Meyer, M. T., Pradella, M., Hinck, D., Sauter, A. W., Heye, T., Boll, D. T., Cyriac, J., Yang, S., et al. (2023) · Radiology: Artificial Intelligence · doi:10.1148/ryai.230024 · Cited by 1,657
A whole-body FDG-PET/CT Dataset with manually annotated Tumor Lesions
Gatidis, S., Hepp, T., Früh, M., La Fougère, C., Nikolaou, K., Pfannenberg, C., Schölkopf, B., Küstner, T., Cyran, C., & Rubin, D. (2022) · Scientific Data · doi:10.1038/s41597-022-01718-3 · Cited by 257
(2024) · doi:10.1109/icip51287.2024.10647307 · Cited by 18
Rapid patient-specific neural networks for intraoperative X-ray to volume registration
Gopalakrishnan, V., Chlorogiannis, D.-D., Abumoussa, A., Larson, A. M., Haouchine, N., Orbach, D. B., Frisken, S., Dey, N., & Golland, P. (2025) · arXiv · doi:10.48550/arxiv.2503.16309 · Cited by 13
Metadata
- Authors
- Sundar, L. K. S., Yu, J., Muzik, O., Kulterer, O. C., Fueger, B., Kifjak, D., Nakuz, T., Shin, H. M., Sima, A. K., Kitzmantl, D., Badawi, R. D., Nardo, L., Cherry, S. R., Spencer, B. A., Hacker, M., & Beyer, T.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2022-06-30
- Volume
- 63
- Issue
- 12
- Pages
- 1941-1948
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W4283772197
- Cited by
- 148
- References
- 8
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.