The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Light sheet‐based fluorescence microscopy: More dimensions, more photons, and less photodamage
Open accessAbstract
Light-sheet-based fluorescence microscopy (LSFM) is a fluorescence technique that combines optical sectioning, the key capability of confocal and two-photon fluorescence microscopes with multiple-view imaging, which is used in optical tomography. In contrast to conventional wide-field and confocal fluorescence microscopes, a light sheet illuminates only the focal plane of the detection objective lens from the side. Excitation is, thus, restricted to the fluorophores in the volume near the focal plane. This provides optical sectioning and allows the use of regular cameras in the detection process. Compared to confocal fluorescence microscopy, LSFM reduces photo bleaching and photo toxicity by up to three orders of magnitude. In LSFM, the specimen is embedded in a transparent block of hydrogel and positioned relative to the stationary light sheet using precise motorized translation and rotation stages. This feature is used to image any plane in a specimen. Additionally, multiple views obtained along different angles can be combined into a single data set with an improved resolution. LSFMs are very well suited for imaging large live specimens over long periods of time. However, they also perform well with very small specimens such as single yeast cells. This perspective introduces the principles of LSFM, explains the challenges of specimen preparation, and introduces the basics of a microscopy that takes advantage of multiple views.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Self-citation
Cited by
Richardson, D. S., & Lichtman, J. W. (2015) · Cell · doi:10.1016/j.cell.2015.06.067 · Cited by 1,095
Phototoxicity in live fluorescence microscopy, and how to avoid it
Icha, J., Weber, M., Waters, J. C., & Norden, C. (2017) · BioEssays · doi:10.1002/bies.201700003 · Cited by 622
Light Sheet Fluorescence Microscopy: A Review
Santi, P. A. (2011) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155410394857 · Cited by 431
Light-sheet microscopy: a tutorial
Olarte, O. E., Andilla, J., Gualda, E. J., & Loza-Alvarez, P. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000111 · Cited by 298
Formalin-Induced Fluorescence Reveals Cell Shape and Morphology in Biological Tissue Samples
Leischner, U., Schierloh, A., Zieglgänsberger, W., & Dodt, H.-U. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010391 · Cited by 40
Metadata
- Authors
- Reynaud, E. G., Kržič, U., Greger, K., & Stelzer, E. H. K.
- Venue
- HFSP Journal
- Publisher
- Informa UK Limited
- Published
- 2008-10
- Volume
- 2
- Issue
- 5
- Pages
- 266-275
- ISSN
- 1955-205X (ISSN-L)
- 1955-2068
- OpenAlex
- W2094314563
- Cited by
- 213
- References
- 1
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Light sheet‐based fluorescence microscopy: More dimensions, more photons, and less photodamage. https://app.cochat.ai/papers/10.2976/1.2974980
- The paper
- Reynaud, E. G., Kržič, U., Greger, K., & Stelzer, E. H. K. (2008). Light sheet‐based fluorescence microscopy: More dimensions, more photons, and less photodamage. HFSP Journal. https://doi.org/10.2976/1.2974980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.