Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
CONCLUSION: Watch-PAT may provide an accurate and clinically effective portable monitoring method for the diagnosis of obstructive sleep apnea (OSA). OBJECTIVE: This study was designed to assess the accuracy and clinical efficacy of a wrist-worn portable device (Watch-PAT 100) to diagnose OSA. METHODS: Twenty-seven participants with suspected OSA underwent full polysomnography (PSG). Finally, 25 subjects successfully underwent portable monitoring using Watch-PAT after full PSG. The study population consisted of 21 males and 4 females, mean age 40.9 +/- 11.2 years (range 21-59). Mean body mass index (BMI) was 26.2 +/- 2.6 kg/m(2) (range 21.2-32.3). All PSG were manually scored according to the new scoring manual of the American Academy of Sleep Medicine (2007) and the Watch-PAT data were analyzed by the automatic algorithm. RESULTS: There was a high correlation of apnea-hypopnea index (AHI) (r = 0.94, p < 0.001) and lowest oxygen saturation (LSAT) (r = 0.90, p < 0.001) between the PSG and the Watch-PAT. A good agreement was also found between PSG AHI, PSG LSAT and PAT AHI, PAT LSAT, respectively. There was a significantly high concordance of the severity of AHI (Kendall tau-b = 0.897, p < 0.001) between the PSG and the Watch-PAT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973 · cited 1×
“If it persists without diagnosis and treatment, critical complications such as adverse cardiovascular sequelae can occur [3,4].”
BackgroundSleep-disordered Breathing and Cardiovascular Disease
SHAHAR, E., WHITNEY, C. W., REDLINE, S., LEE, E. T., NEWMAN, A. B., JAVIER NIETO, F., O'CONNOR, G. T., BOLAND, L. L., SCHWARTZ, J. E., & SAMET, J. M. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.2001008 · Cited by 2,901 · cited 1×
“If it persists without diagnosis and treatment, critical complications such as adverse cardiovascular sequelae can occur [3,4].”
BackgroundKushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Prevalence of Sleep-disordered Breathing in Middle-aged Korean Men and Women
Kim, J., In, K., Kim, J., You, S., Kang, K., Shim, J., Lee, S., Lee, J., Lee, S., Park, C., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200404-519oc · Cited by 516 · cited 1×
“The prevalence of OSA was estimated to be 24–27% in men and 9–16% in women using an apnea-hypopnea index (AHI, the number of apneas plus hypopneas per hour of sleep) [1,2].”
MethodSelf-citationEffects of Varying Approaches for Identifying Respiratory Disturbances on Sleep Apnea Assessment
REDLINE, S., KAPUR, V. K., SANDERS, M. H., QUAN, S. F., GOTTLIEB, D. J., RAPOPORT, D. M., BONEKAT, W. H., SMITH, P. L., KILEY, J. P., & IBER, C. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9904031 · Cited by 225
Pittman, S. D., Ayas, N. T., MacDonald, M. M., Malhotra, A., Fogel, R. B., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.5.923 · Cited by 175
Cited by
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Jonas, D. E., Amick, H. R., Feltner, C., Weber, R. P., Arvanitis, M., Stine, A., Lux, L., & Harris, R. P. (2017) · JAMA · doi:10.1001/jama.2016.19635 · Cited by 267
“of 5 hours per night; data were too limited to provide adherence rates for MADs.(21) A recent Cochrane systematic review of 33 stud-”
BackgroundInfluentialValidation of Watch-PAT-200 Against Polysomnography During Pregnancy
O’Brien, L. M., Bullough, A. S., Shelgikar, A. V., Chames, M. C., Armitage, R., & Chervin, R. D. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1916 · Cited by 133
Abrahamyan, L., Sahakyan, Y., Chung, S., Pechlivanoglou, P., Bielecki, J., Carcone, S. M., Rac, V. E., Fitzpatrick, M., & Krahn, M. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1615-1 · Cited by 67
Impact of Nasal Obstruction on Obstructive Sleep Apnea
Friedman, M., Maley, A., Kelley, K., Leesman, C., Patel, A., Pulver, T., Joseph, N., & Catli, T. (2011) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599811400977 · Cited by 60
“The Watch-PAT system is a noninvasive and validated device that evaluates the presence of sympathetic changes at the vascular level that are concurrent with OSA.(15) The Watch-PAT system derives a respiratory distress index (RDI) from detected changes.”
Method
Metadata
- Authors
- Choi, J. H., Kim, E. J., Kim, Y. S., Choi, J., Kim, T. H., Kwon, S. Y., Lee, H. M., Lee, S. H., Shin, C., & Lee, S. H.
- Venue
- Acta Oto-Laryngologica
- Publisher
- Informa UK Limited
- Published
- 2010-01-18
- Volume
- 130
- Issue
- 7
- Pages
- 838-843
- ISSN
- 0001-6489 (ISSN-L)
- 1651-2251
- OpenAlex
- W2089941212
- Cited by
- 97
- References
- 6
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100. https://app.cochat.ai/papers/10.3109/00016480903431139
- The paper
- Choi, J. H., Kim, E. J., Kim, Y. S., Choi, J., Kim, T. H., Kwon, S. Y., Lee, H. M., Lee, S. H., Shin, C., & Lee, S. H. (2010). Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100. Acta Oto-Laryngologica. https://doi.org/10.3109/00016480903431139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.