Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record.

Comparison between Simultaneously Recorded Auditory-Evoked Magnetic Fields and Potentials Elicited by Ipsilateral, Contralateral and Binaural Tone Burst Stimulation

Pantev, Ch., Lütkenhöner, B, Hoke, M., Lehnertz, K.·1986·International Journal of Audiology

Abstract

Both auditory-evoked magnetic fields (AEMF) and auditory-evoked potentials (AEP) mainly consist of three peaks with latencies of about 50, 100 and 160 ms. Comparison of responses to ipsilateral, contralateral and binaural stimulation yields no significant amplitude or latency differences of the AEP peaks whereas the simultaneously recorded AEMF peaks exhibit a 10 ms shorter latency and an approximately 38% greater amplitude for contralateral versus ipsilateral stimulation. This fact can be due to differences in the strength, location (especially the depth) and the direction of the dipole source, and a decision cannot be made considering the data recorded from just one position. Another finding is that binaural stimulation reduces the peak amplitudes by approximately 25% compared with contralateral stimulation. This result indicates some kind of interference between the ipsilateral and contralateral pathways ('binaural interaction').Les champs magnétiques évoqués auditifs (CMEA) et les potentiels évoqués auditifs (PEA) consistent tous les deux principalement en trois pics de latences d'environ 50,100 et 160 ms. La comparaison des réponses à des stimulations ipsilatérales, controlatérales et binaurales ne montre pas de différences significatives dans les amplitudes et les latences des pics des PEA, tandis que les CMEA enregistrés simultanément présentent une latence plus courte d'environ 10 ms et une amplitude approximativement 38% plus grande pour des stimulations controlatérales par rapport aux stimulations ipsilatérales. Ce fait peut ětre dü à des différences dans l'intensité, la localisation (spécialement la profondeur) et la direction du dipöle source, et on ne peut pas conclure en considérant les enregistrements à partir d'un seul point. Une autre observation est que la stimulation binaurale diminue les amplitudes maximales d'environ 25% par rapport à la stimulation controlatérale. Ce résultat suggère une sorte d'interférence entre les voies ipsilatérales et controlatérales («interaction binaurale»).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/00206098609078369

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pantev, C., Lütkenhöner, B., Hoke, M., & Lehnertz, K.
Venue
International Journal of Audiology
Published
1986-01
Volume
25
Issue
1
Pages
54-61
ISSN
  • 1499-2027 (ISSN-L)
  • 1708-8186
OpenAlex
W2059969614
Cited by
187
References
0
FWCI
4.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison between Simultaneously Recorded Auditory-Evoked Magnetic Fields and Potentials Elicited by Ipsilateral, Contralateral and Binaural Tone Burst Stimulation. https://app.cochat.ai/papers/10.3109/00206098609078369
The paper
Pantev, C., Lütkenhöner, B., Hoke, M., & Lehnertz, K. (1986). Comparison between Simultaneously Recorded Auditory-Evoked Magnetic Fields and Potentials Elicited by Ipsilateral, Contralateral and Binaural Tone Burst Stimulation. International Journal of Audiology. https://doi.org/10.3109/00206098609078369

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.