Analytical goals for thyroid function tests when monitoring patients with untreated subclinical hypothyroidism
The DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIM: Subclinical hypothyroidism is a common condition and it is often monitored biochemically without treatment. For thyroid function tests, analytical goals and critical difference between two tests have been calculated from data on individual variation in euthyroid individuals. Variation in thyroid function tests differs in subclinical hypothyroidism. We aimed to calculate the analytical goals in subclinical hypothyroidism, both in a scientific study setting and in a clinical setting from disease specific variation in thyroid function tests in patients with stable, untreated subclinical hypothyroidism. METHODS: The serum concentration of TSH, fT4 and fT3 were measured monthly for one year in 15 patients with untreated subclinical hypothyroidism and stable TSH. RESULTS: The within-person coefficient of variation (CV%) was 16.6 for TSH, 4.1 for fT4 and 4.0 for fT3, and the calculated goals for analytical imprecision were with CV% of 8.3, 2.0 and 2.0 respectively. The within-batch analytical CV%s for TSH, fT4 and fT3 were 1.7, 3.2 and 2.7 respectively. The between-batch analytical CV% of TSH increased to 6.3. CONCLUSION: In patients with stable untreated subclinical hypothyroidism the goal for analytical imprecision was met with a single analysis of serum TSH, whereas duplicate and triplicate serum measurements of fT3 and fT4 would be necessary. Adding between-batch analytical imprecision for TSH did not alter results, a setting that mirrors every-day clinic.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There are individual variations in thyroid hormones related to factors such as age, circadian rhythms, and hypothyroidism (12–14), but there are no data on BV in patients with T2DM.”
From Biological variation in serum thyroid, iron metabolism, and plasma bone metabolism biomarkers in patients with type 2 diabetes mellitus (2025) · cites this paper as [12]
In the citing paper
“the true nature of TSH referencing is bivariate in relation to an appropriate individual TSH level when combined with a certain FT4 level (101, 186–189).”
From Homeostatic control of the thyroid-pituitary axis: perspectives for diagnosis and treatment (2015) · cites this paper as [188]
Citations
Cites
Subclinical Thyroid Disease: Scientific Review and Guidelines for Diagnosis and Management
Surks, M. I., Ortiz, E., Daniels, G. H., Sawin, C. T., Col, N. F., Cobin, R. H., Franklyn, J. A., Hershman, J. M., Burman, K. D., Denke, M. A., et al. (2004) · JAMA · doi:10.1001/jama.291.2.228 · Cited by 1,800
The Clinical Significance of Subclinical Thyroid Dysfunction
Biondi, B., & Cooper, D. S. (2008) · Endocrine Reviews · doi:10.1210/er.2006-0043 · Cited by 1,418
Laboratory Support for the Diagnosis and Monitoring of Thyroid Disease
(2003) · Thyroid · doi:10.1089/105072503321086962 · Cited by 1,212
Thyroid Status, Disability and Cognitive Function, and Survival in Old Age
Gussekloo, J. (2004) · JAMA · doi:10.1001/jama.292.21.2591 · Cited by 899
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Andersen, S., Pedersen, K. M., Bruun, N. H., & Laurberg, P. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8165 · Cited by 686 · cited 3×
“In a previous study of healthy individuals we found higher intra-individual variances in thyroid function tests when using radioimmunoassays with a lower analytical imprecision for measuring T4 and T3 [5,6].”
BackgroundSelf-citationBiological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
Applications of a New Chemiluminometric Thyrotropin Assay to Subnormal Measurement*
SPENCER, C. A., LoPRESTI, J. S., PATEL, A., GUTTLER, R. B., EIGEN, A., SHEN, D., GRAY, D., & NICOLOFF, J. T. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-2-453 · Cited by 371 · cited 1×
“A key parameter in monitoring subclinical hypothyroidism is measurement of TSH concentration in serum as this responds with logarithmic amplifi cation to minor changes in serum T4 and T3 [21].”
BackgroundThyroid hormone replacement for subclinical hypothyroidism
Villar, H. C. C. E., Saconato, H., Valente, O., & Atallah, Á. N. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003419.pub2 · Cited by 329
Andersen, S., Karmisholt, J., Pedersen, K. M., & Laurberg, P. (2008) · British Journal of Nutrition · doi:10.1017/s0007114507842292 · Cited by 271
Research works printed but not linked: 4
- Petersen PH, 2001, Clin Chem Lab Med, 39, 160
- Harris EK, 1979, Am J Clin Pathol, 72, 374
- Kabadi UM, 1993, Arch Intern Med, 153, 957, 10.1001/archinte.1993.00410080025004 · doi:10.1001/archinte.1993.00410080025004 · Paper page
- Villar HC, 2007, Cochrane Database Syst Rev
Cited by
Homeostatic control of the thyroid-pituitary axis: perspectives for diagnosis and treatment
Hoermann, R., Midgley, J. E. M., Larisch, R., & Dietrich, J. W. (2015) · Frontiers in Endocrinology · doi:10.3389/fendo.2015.00177 · Cited by 143
Karmisholt, J., Andersen, S., & Laurberg, P. (2011) · European Journal of Endocrinology · doi:10.1530/eje-10-1021 · Cited by 86
The TSH upper reference limit: where are we at?
Laurberg, P., Andersen, S., Carlé, A., Karmisholt, J., Knudsen, N., & Pedersen, I. B. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.13 · Cited by 86
Znoyko, S. L., Орлов, А. В., Bragina, V. A., Nikitin, M. P., & Nikitin, P. I. (2020) · Talanta · doi:10.1016/j.talanta.2020.120961 · Cited by 56
TSH Measurement and Its Implications for Personalised Clinical Decision-Making
Hoermann, R., & Midgley, J. E. M. (2012) · Journal of Thyroid Research · doi:10.1155/2012/438037 · Cited by 32
Metadata
- Authors
- Karmisholt, J., Andersen, S., & Laurberg, P.
- Affiliations
- Aalborg University Hospital (DK)
- Corresponding author
- Karmisholt, Jesper
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2010-04-29
- Volume
- 70
- Issue
- 4
- Pages
- 264-268
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2157898430
- Cited by
- 14
- References
- 22
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 1 · 2015: 2 · 2014: 1 · 2012: 1
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- subclinical hypothyroidism, thyroid function tests, critical difference, thyroid-stimulating hormone, free thyroxine, free triiodothyronine, within-person variability, analytical imprecision
- MeSH terms
- Aged, Female, Humans, Hypothyroidism, Male, Middle Aged, Thyroid Function Tests, Thyrotropin, Thyroxine, Triiodothyronine, Biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytical goals for thyroid function tests when monitoring patients with untreated subclinical hypothyroidism. https://app.cochat.ai/papers/10.3109/00365511003782778
- The paper
- Karmisholt, J., Andersen, S., & Laurberg, P. (2010). Analytical goals for thyroid function tests when monitoring patients with untreated subclinical hypothyroidism. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.3109/00365511003782778
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.