Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Analytical goals required for the successful transfer of reference intervals between laboratories within a specified limited geographical area, with a population homogeneous for the quantities, are presented. Diagrams are shown which allow the investigation of the influence of analytical imprecision and bias, both separately and in combination, on the percentage of the population outside each reference limit. Figures to evaluate the effect of population sample size on the size of confidence interval around each reference limit are combined with the diagrams for analytical imprecision and bias. The maximum acceptable percentage of the population outside the limit for the 0.90 confidence interval of each of the means +/- 1.96 s reference limits is 4.6% for a population sample size of 120. Based on this, the maximum acceptable imprecision, with no bias, is 0.6 of the total biological standard deviation (sB) and the maximum acceptable bias, with no imprecision, is 0.25 sB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nelder, J. A., & Bliss, C. I. (1971) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2343879 · Cited by 758
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90151-3 · Cited by 395
Cotlove, E., Harris, E. K., & Williams, G. Z. (1970) · Clinical Chemistry · doi:10.1093/clinchem/16.12.1028 · Cited by 282
Tonks, D. B. (1963) · Clinical Chemistry · doi:10.1093/clinchem/9.2.217 · Cited by 251
Williams, G. Z., Young, D. S., Stein, M. R., & Cotlove, E. (1970) · Clinical Chemistry · doi:10.1093/clinchem/16.12.1016 · Cited by 217
Statistical principles underlying analytic goal-setting in clinical chemistry.
Harris, E. K. (1979) · PubMed · Cited by 178
Medical Significance of Laboratory Results
Barnett, R. N. (1968) · American Journal of Clinical Pathology · doi:10.1093/ajcp/50.6.671 · Cited by 156
Desirable Performance Standards for Clinical Chemistry Tests
Fraser, C. G. (1983) · Advances in clinical chemistry · doi:10.1016/s0065-2423(08)60403-5 · Cited by 124
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
Harris, E. K. (1988) · Archives of Pathology & Laboratory Medicine · Cited by 71
Petitclerc, C., & Wilding, P. M. (1984) · PubMed · Cited by 46
Cited by
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Self-citationReference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Self-citationReference intervals for hemoglobin A1c in pregnant women: data from an Italian multicenter study
Mosca, A., Paleari, R., Dalfrà, M. G., Di Cianni, G., Cuccuru, I., Pellegrini, G., Malloggi, L., Bonomo, M., Granata, S., Ceriotti, F., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.064899 · Cited by 161
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
Metadata
- Authors
- Gowans, E. M. S., Petersen, P. H., Blaabjerg, O., & Hørder, M.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1988-01
- Volume
- 48
- Issue
- 8
- Pages
- 757-764
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2157114400
- Cited by
- 162
- References
- 11
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.