A comparison of measurements of lean body mass derived by bioelectrical impedance, skinfold thickness and total body potassium. A study in obese and non-obese normal subjects
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The measurement of body composition is an important part of metabolic and epidemiological research, but most currently available methods are complex and expensive. We have, therefore, compared measurements of fat mass (FM) and lean body mass (LBM), obtained using a commercially available bioelectrical impedance monitor (The Holtain Body Composition Monitor) (IMP), and by measuring skinfold thickness (SFT), with values obtained by measuring total body potassium (TBK). Twenty subjects, 10 with a body mass index (BMI) less than 30 (kg m-2), (non-obese) and 10 with BMI greater than or equal to 30 (obese) took part in the study.There was a strongly significant linear relationship between LBM calculated from TBK and that calculated from impedance (IMP), in both non-obese and obese groups analysed separately (non-obese: r=0.92; p<0.001 and obese: r=0.92; p<0.001) and together (all: r=0.89; p<0.001). LBM calculated from TBK was strongly linearly correlated with values derived from SFT for non-obese (r=0.91; p<0.001) but not for obese subjects. Mean values of LBM of non-obese subjects derived by each method were not significantly different (TBK: 51.3+10.40 kg; IMP: 53.18±10.37 kg; SFT: 48.87±9.48 kg), but significant differences existed when the subjects were obese (TBK: 51.86±9.65 kg; IMP: 58.69±8.55 kg; SFT: 67.61±8.14 kg: p<0.01).The values of percentage body fat (%FM) calculated from TBK were strongly correlated with those derived by IMP (non-obese: r=0.76; p=0.001; obese: r=0.97; p<0.01; and all r=0.96; p<0.001) and SFT (non-obese: r=0.78: p<0.01; obese: r=0.83: p<0.01; all r=0.94: p<0.001)We conclude that the Holtain Body Impedance Monitor derives values of LBM and %FM that are strongly and significantly linearly correlated with values obtained using a standard method of calculating body composition (TBK). It is more accurate than SFT over a wider range of body weights when TBK is the reference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Cited by
Ferrannini, E., Natali, A., Bell, P., Cavallo-Perin, P., Lalic, N., & Mingrone, G. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119628 · Cited by 898
Endocrine Control of Body Composition in Infancy, Childhood, and Puberty
Veldhuis, J. D., Roemmich, J. N., Richmond, E. J., Rogol, A. D., Lovejoy, J. C., Sheffield-Moore, M., Mauras, N., & Bowers, C. Y. (2005) · Endocrine Reviews · doi:10.1210/er.2003-0038 · Cited by 452
Within- and between-subject variation in commonly measured anthropometric and biochemical variables
Widjaja, A., Morris, R. J., Levy, J. C., Frayn, K. N., Manley, S. E., & Turner, R. C. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.4.561 · Cited by 129
Stolarczyk, L., Heyward, V., Van Loan, M., Hicks, V., Wilson, W., & Reano, L. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/66.1.8 · Cited by 59
Becroft, L., Ooi, G., Forsyth, A., King, S., & Tierney, A. (2019) · International Journal of Obesity · doi:10.1038/s41366-018-0285-9 · Cited by 51
Metadata
- Authors
- Fulcher, G. R., Farrer, M., Walker, M., Rodham, D., Clayton, B., & Alberti, K. G. M. M.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1991-01
- Volume
- 51
- Issue
- 3
- Pages
- 245-253
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2019099806
- Cited by
- 44
- References
- 2
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of measurements of lean body mass derived by bioelectrical impedance, skinfold thickness and total body potassium. A study in obese and non-obese normal subjects. https://app.cochat.ai/papers/10.3109/00365519109091611
- The paper
- Fulcher, G. R., Farrer, M., Walker, M., Rodham, D., Clayton, B., & Alberti, K. G. M. M. (1991). A comparison of measurements of lean body mass derived by bioelectrical impedance, skinfold thickness and total body potassium. A study in obese and non-obese normal subjects. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.3109/00365519109091611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.