CoChat

A comparison of measurements of lean body mass derived by bioelectrical impedance, skinfold thickness and total body potassium. A study in obese and non-obese normal subjects

Fulcher, G. R., Farrer, M., Walker, M., Rodham, D., Clayton, B., Alberti, K. G. M. M. · 1991 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 44

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The measurement of body composition is an important part of metabolic and epidemiological research, but most currently available methods are complex and expensive. We have, therefore, compared measurements of fat mass (FM) and lean body mass (LBM), obtained using a commercially available bioelectrical impedance monitor (The Holtain Body Composition Monitor) (IMP), and by measuring skinfold thickness (SFT), with values obtained by measuring total body potassium (TBK). Twenty subjects, 10 with a body mass index (BMI) less than 30 (kg m-2), (non-obese) and 10 with BMI greater than or equal to 30 (obese) took part in the study.There was a strongly significant linear relationship between LBM calculated from TBK and that calculated from impedance (IMP), in both non-obese and obese groups analysed separately (non-obese: r=0.92; p<0.001 and obese: r=0.92; p<0.001) and together (all: r=0.89; p<0.001). LBM calculated from TBK was strongly linearly correlated with values derived from SFT for non-obese (r=0.91; p<0.001) but not for obese subjects. Mean values of LBM of non-obese subjects derived by each method were not significantly different (TBK: 51.3+10.40 kg; IMP: 53.18±10.37 kg; SFT: 48.87±9.48 kg), but significant differences existed when the subjects were obese (TBK: 51.86±9.65 kg; IMP: 58.69±8.55 kg; SFT: 67.61±8.14 kg: p<0.01).The values of percentage body fat (%FM) calculated from TBK were strongly correlated with those derived by IMP (non-obese: r=0.76; p=0.001; obese: r=0.97; p<0.01; and all r=0.96; p<0.001) and SFT (non-obese: r=0.78: p<0.01; obese: r=0.83: p<0.01; all r=0.94: p<0.001)We conclude that the Holtain Body Impedance Monitor derives values of LBM and %FM that are strongly and significantly linearly correlated with values obtained using a standard method of calculating body composition (TBK). It is more accurate than SFT over a wider range of body weights when TBK is the reference.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/00365519109091611

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 44

Metadata

Authors
Fulcher, G. R., Farrer, M., Walker, M., Rodham, D., Clayton, B., & Alberti, K. G. M. M.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
1991-01
Volume
51
Issue
3
Pages
245-253
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2019099806
Cited by
44
References
2
FWCI
0.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of measurements of lean body mass derived by bioelectrical impedance, skinfold thickness and total body potassium. A study in obese and non-obese normal subjects. https://app.cochat.ai/papers/10.3109/00365519109091611
The paper
Fulcher, G. R., Farrer, M., Walker, M., Rodham, D., Clayton, B., & Alberti, K. G. M. M. (1991). A comparison of measurements of lean body mass derived by bioelectrical impedance, skinfold thickness and total body potassium. A study in obese and non-obese normal subjects. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.3109/00365519109091611

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.