Complications after percutaneous endoscopic gastrostomy in a prospective study
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Insertion of a percutaneous endoscopic gastrostomy (PEG) is an increasingly common procedure in patients with nutritional needs and dysphagia. Better knowledge of rates and patterns of complications after PEG might influence decision-making. MATERIAL AND METHODS: The objective was to prospectively evaluate the rate of six pre-defined complications (leakage, diarrhea, constipation, abdominal pain, fever and peristomal infection) and mortality occurring within 2 months after PEG in an unselected sample of patients. All patients (n = 484) who had a PEG inserted at the hospital during the study period were included. Kaplan-Meier curves were used to estimate mortality over the first 60 days following PEG and Fisher's exact test was used to test equality of proportions. RESULTS: Of the 484 patients included, 85 (18%) died within 2 months after PEG insertion. The risk of early mortality was higher in the group with neurological disease than in the group with a tumor as indication (p < 0.001). After excluding mortality, the overall complication rates at 2 weeks and 2 months were 39% and 27%, respectively. The most common complications within 2 weeks were abdominal pain (13%), peristomal infection (11%), diarrhea (11%) and leakage (10%). At 2 months the most frequent complications were diarrhea (10%), leakage (8%) and peristomal infection (6%). CONCLUSIONS: In the short-term perspective, there is a substantial risk of complications, including mortality, after PEG insertion. This should be considered during clinical decision-making and when informing the patients and caregivers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gastrostomy without laparotomy: A percutaneous endoscopic technique
Gauderer, M. W. L., Ponsky, J. L., & Izant, R. J. (1980) · Journal of Pediatric Surgery · doi:10.1016/s0022-3468(80)80296-x · Cited by 2,088 · cited 1×
“Since its introduction in 1980 [1], the use of PEG has increased considerably.”
BackgroundPercutaneous endoscopic gastrostomy
Larson, D. E., Burton, D. D., Schroeder, K. W., & DiMagno, E. P. (1987) · Gastroenterology · doi:10.1016/0016-5085(87)90312-x · Cited by 836
Russell, T. R., Brotman, M., & Norris, F. (1984) · The American Journal of Surgery · doi:10.1016/0002-9610(84)90300-3 · Cited by 393
Sanders, D. S., Carter, M. J., D'Silva, J., James, G., Bolton, R. P., & Bardhan, K. D. (2000) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2000.02079.x · Cited by 300
Gastrostomy Placement and Mortality Among Hospitalized Medicare Beneficiaries
Grant, M. D. (1998) · JAMA · doi:10.1001/jama.279.24.1973 · Cited by 268
Grant, D. G., Bradley, P. T., Pothier, D. D., Bailey, D., Caldera, S., Baldwin, D. L., & Birchall, M. A. (2009) · Clinical Otolaryngology · doi:10.1111/j.1749-4486.2009.01889.x · Cited by 227 · cited 2×
“The reported complication data are, however, unreliable, being based mainly on retrospective data from selected, small patient series [5,6].”
BackgroundOutcomes of Percutaneous Endoscopic Gastrostomy Among Older Adults in a Community Setting
Callahan, C. M., Haag, K. M., Weinberger, M., Tierney, W. M., Buchanan, N. N., Stump, T. E., & Nisi, R. (2000) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2000.tb04779.x · Cited by 225
Complications of Percutaneous Endoscopic Gastrostomy
Schapiro, G. D., & Edmundowicz, S. A. (1996) · Gastrointestinal Endoscopy Clinics of North America · doi:10.1016/s1052-5157(18)30369-6 · Cited by 211
Systemic antimicrobial prophylaxis for percutaneous endoscopic gastrostomy
Lipp, A., & Lusardi, G. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005571.pub3 · Cited by 184
Sharma, V. K., & Howden, C. W. (2000) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2000.03283.x · Cited by 175
Cited by
Percutaneous endoscopic gastrostomy: Indications, technique, complications and management
Rahnemai-Azar, A. A. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7739 · Cited by 578
Gastroenteric tube feeding: Techniques, problems and solutions
Blumenstein, I. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i26.8505 · Cited by 455
Fernandez, H. H., Standaert, D. G., Hauser, R. A., Lang, A. E., Fung, V. S. C., Klostermann, F., Lew, M. F., Odin, P., Steiger, M., Yakupov, E. Z., et al. (2015) · Movement Disorders · doi:10.1002/mds.26123 · Cited by 247
Metadata
- Authors
- Blomberg, J., Lagergren, J., Martin, L., Mattsson, F., & Lagergren, P.
- Venue
- Scandinavian Journal of Gastroenterology
- Publisher
- Informa UK Limited
- Published
- 2012-04-04
- Volume
- 47
- Issue
- 6
- Pages
- 737-742
- ISSN
- 0036-5521 (ISSN-L)
- 1502-7708
- OpenAlex
- W2060629773
- Cited by
- 185
- References
- 25
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications after percutaneous endoscopic gastrostomy in a prospective study. https://app.cochat.ai/papers/10.3109/00365521.2012.654404
- The paper
- Blomberg, J., Lagergren, J., Martin, L., Mattsson, F., & Lagergren, P. (2012). Complications after percutaneous endoscopic gastrostomy in a prospective study. Scandinavian Journal of Gastroenterology. https://doi.org/10.3109/00365521.2012.654404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.