Deposition of Large Particles in Human Lung
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Twenty-four nonsmoking males, all without history of pulmonary disease, were randomly divided into four groups of six subjects each. The subjects in each group inhaled monodisperse Teflon particles labelled with 111In (half-life 2.83 days); 8.2, 11.5, 13.7 and 16.4 micron aerodynamic diameter, respectively. Radioactivity in head and throat, lung and stomach was determined after 0, 3 and 24 hrs using a profile scanner. For some subjects radioactivity was also determined using a whole-body scanner at 3.5 and 24 hrs. After the 24-hr determination the subjects inhaled labelled Teflon particles again, this time with a filter in front of the mouth. Average values for total deposition in the body, obtained using a profile scanner, whole-body scanner and filter measurements, agreed fairly well. Lung retention values obtained by whole-body and profile scanning also agreed well. The average deposition in the lung, expressed as a percentage of total deposition, was 49, 31, 21 and 13% for the four particle sizes (8.2-16.4 micron). Alveolar deposition, determined as retention at 24 hrs and expressed in percent of total deposition, was 15, 4, 4 and 1%. For the smallest particle sizes the deposition values agreed with earlier investigations. However, for the larger particles the two deposition values were higher than expected when compared to earlier studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deposition, retention, and clearance of inhaled particles.
Lippmann, M., Yeates, D. B., & Albert, R. E. (1980) · Occupational and Environmental Medicine · doi:10.1136/oem.37.4.337 · Cited by 557
Cited by
Luczynska, C. M., Li, Y., Chapman, M. D., & Platts-Mills, T. A. E. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.361 · Cited by 340
Aerosol Deposition in the Extrathoracic Region
Cheng, Y. S. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300906 · Cited by 245
“There were many in vivo regional deposition studies for mouth-breathing using adult human volunteers (Lippmann and Albert 1969; Foord et al. 1978; Chan and Lippmann 1980; Stahlhofen et al. 1980, 1983; Emmett et al. 1982; Svartengren et al. 1987; Bowes and Swift 1989).”
Backgroundde Blay, F., Heymann, P. W., Chapman, M. D., & Platts-Mills, T. A. E. (1991) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(91)90249-n · Cited by 190
Long-term clearance from small airways decreases with age
Svartengren, M., Falk, R., & Philipson, K. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00002105 · Cited by 144
“The radioactivity deposited in the lungs was 0.1 MBq [ 31 ].”
MethodInfluentialSelf-citationEffects of various vacuum cleaners on the airborne content of major cat allergen (Fel d 1)
de Blay, F., Spirlet, F., Gries, P., Casel, S., Ott, M., & Pauli, G. (1998) · Allergy · doi:10.1111/j.1398-9995.1998.tb03914.x · Cited by 26
Metadata
- Authors
- Svartengren, M., Falk, R., Linnman, L., Philipson, K., & Camner, P.
- Venue
- Experimental Lung Research
- Publisher
- Informa UK Limited
- Published
- 1987-01
- Volume
- 12
- Issue
- 1
- Pages
- 75-88
- ISSN
- 0190-2148 (ISSN-L)
- 1521-0499
- OpenAlex
- W2058968960
- Cited by
- 67
- References
- 1
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.