CoChat

The Reliability and Patient Acceptability of the SmartTrack Device: A New Electronic Monitor and Reminder Device for Metered Dose Inhalers

Foster, Juliet M., Smith, Lorraine, Usherwood, Tim, Sawyer, Susan M., Rand, Cynthia S., Reddel, Helen K. · 2012 · Journal of Asthma
Cited by 62

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The SmartTrack (ST) is a new adherence monitoring device for pressurized metered-dose inhalers (pMDI), with remote upload and ringtone reminder capabilities. Our aim was to assess its reliability and patient acceptability. METHODS: Baseline Quality Control (QC): Actuation log accuracy and device functionality tests were undertaken. Simulated Patient Use: Salmeterol/fluticasone inhalers with STs were actuated two times twice daily for 48 h. Accuracy of reminders, data logging, and uploads was tested. Patient Field Testing: Devices were quality tested before dispensing. Asthma patients each field-tested one ST for 7 days and recorded actuations in a diary. Uploaded data were compared to pMDI dose counter and patient diaries. Patient-reported ease of use for the ST was recorded. RESULTS: Baseline QC: 9/10 devices had 100% accuracy; one had an electrical circuit failure. Simulated Patient Use: Accuracy was 99% (2/342 actuations duplicated). Patient Field Testing: One device failed pre-dispensing testing (electrical circuit failure). Eight devices were field-tested by asthma patients (mean age 45, 5 females). Mean actuation log accuracy was 97%. Reminders were 100% accurate. All devices successfully uploaded data. Average patient-rated difficulty of use was 6/100 (1 = extremely easy, 100 = extremely difficult). CONCLUSIONS: The ST has acceptable reliability and utility comparable to other electronic monitoring devices. Its remote data upload capability, reminder functions for missed doses, and graphical display of medication use for patient- and physician-feedback are useful additional features.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/02770903.2012.684253

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Accurate Assessment of Adherence

    Daniels, T., Goodacre, L., Sutton, C., Pollard, K., Conway, S., & Peckham, D. (2011) · Chest · doi:10.1378/chest.09-3074 · Cited by 210 · cited 1×

    “In the context of severe asthma, the high cost or risk associated with new biological add-on therapies may justify expenditure on electronic monitoring as disentangling poor treatment response from poor adherence can be extremely difficult in clinical practice (17).”
    Background

Show all 1 references

Cited by

Metadata

Authors
Foster, J. M., Smith, L., Usherwood, T., Sawyer, S. M., Rand, C. S., & Reddel, H. K.
Venue
Journal of Asthma
Published
2012-06-28
Volume
49
Issue
6
Pages
657-662
ISSN
  • 0277-0903 (ISSN-L)
  • 1532-4303
OpenAlex
W2019066158
Cited by
62
References
1
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.