Optimising Imaging Parameters for Post Mortem MR Imaging of the Human Brain
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: MR imaging of post mortem brains has the potential to yield volumetric information and define the extent of structural changes prior to pathological examination. Although standard T2-weighted clinical imaging sequences have been used for the examination of formalin-fixed brains, these protocols may not yield optimum contrast. We examined the effect of varying durations of formalin fixation on the transverse relaxation time (T2) and the tissue spin density. Material and Methods: Three post mortem brains were examined weekly during formalin fixation from the unfixed state to 35 days fixation. Standard MR spin-echo imaging was used at 5 echo times (20–100 ms) to calculate transverse relaxation time (T2) and spin density. Results: T2 decreased significantly (ANOVA, p<0.001) in both grey and white matter by 7 days fixation and there was a further (but non-significant) trend towards lower values between 7 and 35 days. Grey and white matter T2 times converged with fixation. Conversely, the grey to white matter spin density ratio increased from 1.19±0.01 to 1.54±0.06 over five weeks of fixation. Conclusion: Our results suggest that spin density-weighted imaging sequences would provide improved grey to white matter contrast over T2-weighted sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Awad, I. A., Johnson, P. C., Spetzler, R. F., & Hodak, J. A. (1986) · Stroke · doi:10.1161/01.str.17.6.1090 · Cited by 572
Cited by
Heterogeneity of small vessel disease: a systematic review of MRI and histopathology correlations
Gouw, A. A., Seewann, A., van der Flier, W. M., Barkhof, F., Rozemuller, A. M., Scheltens, P., & Geurts, J. J. G. (2011) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.204685 · Cited by 766
Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305
“Previous studies (10,13) indicated that formaldehyde immer-”
BackgroundSchrag, M., McAuley, G., Pomakian, J., Jiffry, A., Tung, S., Mueller, C., Vinters, H. V., Haacke, E. M., Holshouser, B., Kido, D., et al. (2010) · Acta Neuropathologica · doi:10.1007/s00401-009-0615-z · Cited by 289
Quantitative magnetic resonance of postmortem multiple sclerosis brain before and after fixation
Schmierer, K., Wheeler‐Kingshott, C. A. M., Tozer, D. J., Boulby, P. A., Parkes, H. G., Yousry, T. A., Scaravilli, F., Barker, G. J., Tofts, P. S., & Miller, D. H. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21487 · Cited by 281
“Although in our samples, time of fixation did not seem to affect the qMR data obtained, a standardized interval between immersion in fixative and MR acquisition of at least five weeks would be advisable (42,48).”
BackgroundHigh‐resolution MRI reflects myeloarchitecture and cytoarchitecture of human cerebral cortex
Eickhoff, S., Walters, N. B., Schleicher, A., Kril, J., Egan, G. F., Zilles, K., Watson, J. D. G., & Amunts, K. (2005) · Human Brain Mapping · doi:10.1002/hbm.20082 · Cited by 243
“Nevertheless, these T2weighted postmortem MRIs showed a reverse contrast to the in vivo T1 MRI, very similar to in vivo T2 images [Barkhof et al., 1993; Blamire et al., 1999].”
Result
Metadata
- Authors
- Blamire, A. M., Rowe, J. G., Styles, P., & McDonald, B.
- Venue
- Acta Radiologica
- Publisher
- SAGE Publications
- Published
- 1999-11
- Volume
- 40
- Issue
- 6
- Pages
- 593-597
- ISSN
- 0284-1851 (ISSN-L)
- 1600-0455
- OpenAlex
- W2016800756
- Cited by
- 70
- References
- 1
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimising Imaging Parameters for Post Mortem MR Imaging of the Human Brain. https://app.cochat.ai/papers/10.3109/02841859909175593
- The paper
- Blamire, A. M., Rowe, J. G., Styles, P., & McDonald, B. (1999). Optimising Imaging Parameters for Post Mortem MR Imaging of the Human Brain. Acta Radiologica. https://doi.org/10.3109/02841859909175593
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.