CoChat

Identifying hypoxia in human tumors: A correlation study between18F-FMISO PET and the Eppendorf oxygen-sensitive electrode

Open access
Mortensen, Lise Saksø, Buus, Simon, Nordsmark, Marianne, Bentzen, Lise, Munk, Ole Lajord, Keiding, Susanne, Overgaard, Jens · 2010 · Acta Oncologica
Cited by 79

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Polarographic oxygen-sensitive electrodes have demonstrated prognostic significance of hypoxia. However, its routine application is limited. (18)F-FMISO PET scans are a noninvasive approach, able to measure spatial and temporal changes in hypoxia. The aim of this study was to examine the association between measures of hypoxia defined by functional imaging and Eppendorf pO(2) electrodes. MATERIALS AND METHODS: A total of 18 patients were included, nine squamous cell carcinoma of the head and neck and nine soft tissue tumors. The tumor volume was defined by CT, MRI, (18)FDG-PET or by clinical examination. The oxygenation status of the tumors was assessed using (18)F-FMISO PET imaging followed by Eppendorf pO(2) electrode measurements. Data were compared in a 'virtual voxel', resulting in individual histograms from each tumor. RESULTS: The percentages of pO(2) ≤ 5 mmHg ranged from 9 to 94% (median 43%) for all 18 tumors. For (18)F-FMISO PET the T/M ratio ranged from 0.70 to 2.38 (median 1.13). Analyzing the virtual voxel histograms tumors could be categorized in three groups: Well oxygenated tumors with no hypoxia and concordance between the (18)F-FMISO data and the Eppendorf measurements, hypoxic tumors likewise with concordance between the two assays and inconclusive tumors with no concordance between the assays. CONCLUSION: This study analyzed the relationship between (18)F-FMISO PET and Eppendorf pO(2) electrode measurements by use of a virtual voxel model. There was a spectrum of hypoxia among tumors that can be detected by both assays. However no correlation was observed, and in general tumors were more hypoxic based on Eppendorf pO(2) measurements as compared to (18)F-FMISO PET.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/0284186x.2010.516274

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Mortensen, L. S., Buus, S., Nordsmark, M., Bentzen, L., Munk, O. L., Keiding, S., & Overgaard, J.
Venue
Acta Oncologica
Published
2010-09-13
Volume
49
Issue
7
Pages
934-940
ISSN
  • 0284-186X (ISSN-L)
  • 1651-226X
OpenAlex
W2061111550
Cited by
79
References
3
FWCI
1.63
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.