The Influence of Mechanical Forces on the Glycosaminoglycan Content of the Rabbit Flexor Digitorum Profundus Tendon
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The physical forces acting on the flexor digitorum profundus tendon of the rabbit were altered by anterior translocation of the tendon. The glycosaminoglycan (GAG) content was determined in regions of the tendon previously under tension or previously subjected to pressure. There was an increase in the GAG content in the original tension transmitting region. Initially this was due to increased hyaluronic acid and chondroitin sulfate content during the early remodeling phase. Later when tension was restored to the translocated tendon, the content of these two GAG decreased to normal values while the high overall GAG concentration was maintained by increased amounts of dermatan sulfate. Finally the dermatan sulfate content and the total GAG content returned to normal values.The original pressure bearing region showed a rapid loss of total GAG. This was mainly due to a loss of chondroitin sulfate component, and eventually the region showed a GAG composition similar to that of normal tension transmitting tendon. Replacement of the translocated tendon to its normal position resulted in a slow replacement of the GAG, particularly chondroitin sulfate, in the pressure bearing region. The extent of recovery appeared to be dependent on the length of time the tendon had been left in the translocated position. Attempts to form a new pressure bearing structure in another part of the tendon also resulted in changes in the proportions of the GAG, but little change in total GAG content.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A modified uronic acid carbazole reaction
Bitter, T., & Muir, H. M. (1962) · Analytical Biochemistry · doi:10.1016/0003-2697(62)90095-7 · Cited by 6,274
Cyclic Stretching Stimulates Synthesis of Matrix Components by Arterial Smooth Muscle Cells in Vitro
Leung, D. Y. M., Glagov, S., & Mathews, M. B. (1976) · Science · doi:10.1126/science.128820 · Cited by 698
Aliphatic Ammonium Salts in the Assay of Acidic Polysaccharides from Tissues
Scott, J. E. (1960) · Methods of Biochemical Analysis · doi:10.1002/9780470110249.ch4 · Cited by 678
Caterson, B., & Lowther, D. A. (1978) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(78)90171-x · Cited by 147
The proteoglycan content and the axial periodicity of collagen in tendon
Gillard, G. C., Merrilees, M. J., Bell-booth, P. G., Reilly, H. C., & Flint, M. H. (1977) · Biochemical Journal · doi:10.1042/bj1630145 · Cited by 118
Self-citationThe Masson staining of collagen ? an explanation of an apparent paradox
Flint, M. H., Lyons, M. F., Meaney, M. F., & Williams, D. E. (1975) · The Histochemical Journal · doi:10.1007/bf01003791 · Cited by 66
Self-citationFlint, M. H., & Merrilees, M. J. (1977) · The Histochemical Journal · doi:10.1007/bf01007005 · Cited by 23
Self-citationExtraction of acid mucopolysaccharides from bovine heart valves
Lowther, D. A., Toole, B. P., & Meyer, F. A. (1967) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(67)90270-6 · Cited by 21
Changes in Z-disc width of vertebrate skeletal muscle following tenotomy
Chase, D., & Ullrick, W. C. (1977) · Cellular and Molecular Life Sciences · doi:10.1007/bf01922312 · Cited by 7
Comper, W. D., Lisberg, W., & Veis, A. (1976) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(76)90209-5 · Cited by 3
Cited by
Biosynthetic response of cartilage explants to dynamic compression
Sah, R. L. ‐., Kim, Y., Doong, J. H., Grodzinsky, A. J., Plass, A. H. K., & Sandy, J. D. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070502 · Cited by 875
Fibrocartilage in tendons and ligaments — an adaptation to compressive load
BENJAMIN, M., & RALPHS, J. R. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19340481.x · Cited by 787
Cartilage Tissue Remodeling in Response to Mechanical Forces
Grodzinsky, A. J., Levenston, M. E., Jin, M., & Frank, E. H. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.691 · Cited by 642
The pathogenesis of tendinopathy. A molecular perspective
Riley, G. (2004) · Rheumatology · doi:10.1093/rheumatology/keg448 · Cited by 543
Amiel, D., Kleiner, J. B., Roux, R. D., Harwood, F. L., & Akeson, W. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040204 · Cited by 520
Metadata
- Authors
- Gillard, G. C., Reilly, H. C., Bell-booth, P. G., & Flint, M. H.
- Venue
- Connective Tissue Research
- Publisher
- Informa UK Limited
- Published
- 1979-01
- Volume
- 7
- Issue
- 1
- Pages
- 37-46
- ISSN
- 0300-8207 (ISSN-L)
- 1607-8438
- OpenAlex
- W1995728060
- Cited by
- 227
- References
- 10
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.