Considerations Regarding the Structure of the Mammalian Mineralized Osteoid from Viewpoint of the Generalized Packing Model
The DOI matches its Crossref record.
Abstract
The relative magnitudes of mineral, organic and water contents of dense mammalian bone are calculated by a new theory based on recent findings: (1) The neutron diffraction studies of mineralized tissues with different densities demonstrated an inverse relationship between wet density and the equatorial diffraction spacing of the collagen. (2) The neutron studies showed there was very little mineral within the collagen fibrils. (3) A generalized packing model for collagen has been advanced to show how the equatorial spacing can be varied depending on tissue type, water content, and mineral content. (4) The water content of collagen fibrils when calculated from the generalized packing model matches the experimentally determined values for rat tail tendon fibers, bone matrix, and fully mineralized bone. A computational model was developed based on the generalized packing model. It provides a unifying approach to explain many features of mineralized fibrous collagenous tissues. The results are presented as estimates of the mineralized collagen fibril density, the volume fraction of collagen in bone, the density of the extrafibrillar space, the fraction of the e.f. space occupied by mineral and the ratio of mineral within collagen to total mineral content, each expressed as a function of wet bone density. A useful data base, available from previous studies, related mineral, organic and water weight fractions to wet bone density, for a density range from 1.7 g/cc for deer antler to 2.7 g/cc for porpoise petrosal. A second order polynomial was found for each weight fraction component, with bone density as the input variable, with a standard deviation less than 2% of total bone weight. This permits the bone properties to be related to a single variable, the wet bone density. It is seen that compacting the collagen fibrils as well as reducing the organic component weight fraction are two important factors determining the structure of the mineralized osteoid. It was concluded that voids and pore spaces may occupy at least 5% of the bone volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mineralized Collagen Fibrils: A Mechanical Model with a Staggered Arrangement of Mineral Particles
Jäger, I., & Fratzl, P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76426-5 · Cited by 793
Lamellar Bone: Structure–Function Relations
Weiner, S., Traub, W., & Wagner, H. D. (1999) · Journal of Structural Biology · doi:10.1006/jsbi.1999.4107 · Cited by 674
Landis, W. J., Hodgens, K. J., Arena, J., Song, M. J., & McEwen, B. F. (1996) · Microscopy Research and Technique · doi:10.1002/(sici)1097-0029(19960201)33:2<192::aid-jemt9>3.0.co;2-v · Cited by 447
Hierarchical Self-Assembly of Nano-Fibrils in Mineralized Collagen
Zhang, W., Liao, S. S., & Cui, F. Z. (2003) · Chemistry of Materials · doi:10.1021/cm030080g · Cited by 385
Fritsch, A., & Hellmich, C. (2007) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2006.09.013 · Cited by 321
Stem Cell Differentiation is Regulated by Extracellular Matrix Mechanics
Smith, L. R., Cho, S., & Discher, D. E. (2018) · Physiology · doi:10.1152/physiol.00026.2017 · Cited by 280
Aging of Microstructural Compartments in Human Compact Bone
Akkus, O., Polyakova-Akkus, A., Adar, F., & Schaffler, M. B. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.6.1012 · Cited by 263
Hellmich, C., Barthélémy, J.-F., & Dormieux, L. (2004) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2004.05.004 · Cited by 210
Multiscale modeling of elastic properties of cortical bone
Hamed, E., Lee, Y., & Jasiuk, I. (2010) · Acta Mechanica · doi:10.1007/s00707-010-0326-5 · Cited by 199
“References Mineral volume fraction (%) Currey [8] 50 Lees [ 22 ] 45 Sasaki et al. [90] 50 Wagner and Weiner [91 ]3 5 Jager and Fratzl [92 ]4 3 Kotha and Guzelso [18 ]5 0 Ji and Gao [17] 45 Nikolov and Raabe [15 ]5 2”
BackgroundInfluentialCollagen packing and mineralization. An x-ray scattering investigation of turkey leg tendon
Fratzl, P., Fratzl-Zelman, N., & Klaushofer, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81362-6 · Cited by 160
The use of X-ray scattering techniques to determine corneal ultrastructure
Meek, K. M., & Quantock, A. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00016-1 · Cited by 139
Specimen-specific multi-scale model for the anisotropic elastic constants of human cortical bone
Deuerling, J. M., Yue, W., Espinoza Orías, A. A., & Roeder, R. K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.002 · Cited by 47
“The density of collagen has been reported as 1.23 g/cm3 (Black and Mattson, 1982), 1.28 g/cm3 (Wang et al., 2001), and 1.41 g/cm3 (Lees, 1987; Lees and Heeley, 1981), and the density of apatite bone mineral has been reported as 2.86 g/cm3 (Black and Mattson, 1982), 3.00 g/cm3 (Wang et al., 2001),…”
BackgroundInfluential
Metadata
- Authors
- Lees, S.
- Venue
- Connective Tissue Research
- Publisher
- Informa UK Limited
- Published
- 1987-01
- Volume
- 16
- Issue
- 4
- Pages
- 281-303
- ISSN
- 0300-8207 (ISSN-L)
- 1607-8438
- OpenAlex
- W2162628248
- Cited by
- 158
- References
- 0
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.