The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk
Open accessAbstract
The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk was studied using finite element (FE) models of electromyogram (EMG) signal propagation. A FE model of the upper arm consisted of skin, fat, muscle and bone tissues in concentric layers. Single muscle fibre action potentials were simulated for muscle fibres at a variety of depths and combined to simulate surface EMG interference patterns. As fat layers of 3, 9 and 18 mm were added to the model, the RMS (root mean square) amplitude of the surface EMG signal directly above the centre of the active muscle decreased by 31.3, 80.2 and 90.0%, respectively. Similarly, surface EMG cross-talk above the region of inactive muscle increased as the fat layer thickness increased. The surface EMG RMS amplitude fell below 5% of its value above the centre of the muscle at 14 degrees, 17 degrees, 34 degrees and 47 degrees from the edge of the active muscle with fat layers of 0, 3, 9 and 18 mm, respectively. An additional model was developed with the subcutaneous fat layer thinned from 9 mm to 3 mm in a small, focal region under a pair of recording electrodes. Reducing the fat layer in this manner caused the surface EMG amplitude at the electrodes to increase by 241% and decreased the EMG cross-talk by 68%; this was near the values for the 3 mm uniform fat layer. This demonstrates that fat reduction surgery can increase surface EMG signal amplitude and signal independence for improved prosthesis control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Cited by
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationVigotsky, A. D., Halperin, I., Lehman, G. J., Trajano, G. S., & Vieira, T. M. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2017.00985 · Cited by 503
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
Metadata
- Authors
- Kuiken, T. A., Lowery, M. M., & Stoykov, N. S.
- Venue
- Prosthetics & Orthotics International
- Published
- 2003-04
- Volume
- 27
- Issue
- 1
- Pages
- 48-54
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W1859888177
- Cited by
- 196
- References
- 1
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk. https://app.cochat.ai/papers/10.3109/03093640309167976
- The paper
- Kuiken, T. A., Lowery, M. M., & Stoykov, N. S. (2003). The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk. Prosthetics & Orthotics International. https://doi.org/10.3109/03093640309167976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.