Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects
Open accessThe DOI matches its Crossref record.
Abstract
The purpose of this research was to evaluate a newly developed system for assessing and providing feedback of gait symmetry information in real time to subjects walking on a motorised treadmill (the CCF Treadmill). The advantages of the system are that it allows the rapid collection and comparison of temporal and kinetic parameters of gait for multiple successive strides, at a constant known speed, without forcing subjects to target their footsteps. Gait asymmetries of six normal (mean age 42.7 years) and six unilateral transtibial amputee subjects (mean age 41.7, and average 6.0 years using a prosthesis) were quantified. The amputee group was the reevaluated after receiving five minutes of training with each of three different types of real-time visual feedback (RTVF). Asymmetries in the measured parameters before feedback were 4.6 times greater in the amputee population than in the normal group, and were consistent with the finding of previous authors. Significant decreases in gait asymmetry were demonstrated for all forms of feedback after amputees received feedback training. Results, however, indicated that gait asymmetries for different variables are not necessarily related, and that more work needs to be done to identify those variables for which attaining a more symmetrical gait pattern is most beneficial. Further work also needs to be done to determine the long term effects of such RTVF training. The CCF Treadmill and RTVF were shown to be potentially useful tools both for defining rehabilitation targets and for quantifying patients' progress towards those goals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Giggins, O. M., Persson, U., & Caulfield, B. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-60 · Cited by 760
Gait retraining to reduce lower extremity loading in runners
Crowell, H. P., & Davis, I. S. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.09.003 · Cited by 403
“Real-time feedback from instrumented treadmills has helped trans-tibial amputees (Dingwell et al., 1996) and individuals with total hip replacements (White and Lifeso, 2005) to improve their symmetry of loading.”
Force treadmill for measuring vertical and horizontal ground reaction forces
Kram, R., Griffin, T. M., Donelan, J. M., & Chang, Y. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.764 · Cited by 239
“(11) have developed clever algorithms to separate the individual foot vertical forces for use with a FTM.”
Charkhkar, H., Shell, C. E., Marasco, P. D., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac964 · Cited by 131
“Sensory substitution, such as audio and visual feedback, can positively impact gait symmetry in transtibial amputees [22, 23].”
Background
Metadata
- Authors
- Dingwell, J. B., Davis, B. L., & Frazder, D. M.
- Venue
- Prosthetics & Orthotics International
- Published
- 1996-08
- Volume
- 20
- Issue
- 2
- Pages
- 101-110
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W2130751921
- Cited by
- 141
- References
- 0
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects. https://app.cochat.ai/papers/10.3109/03093649609164426
- The paper
- Dingwell, J. B., Davis, B. L., & Frazder, D. M. (1996). Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects. Prosthetics & Orthotics International. https://doi.org/10.3109/03093649609164426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.