Feasibility of Raman spectroscopy as PAT tool in active coating
The DOI matches its Crossref record.
Abstract
BACKGROUND: Active coating is a specific application of film coating where the active ingredient is comprised in the coating layer. This implementation is a challenging operation regarding the achievement of desired amount of coating and coating uniformity. To guarantee the quality of such dosage forms it is desirable to develop a tool that is able to monitor the coating operation and detect the end of the process. METHOD: Coating experiments were performed at which the model drug diprophylline is coated in a pan coater on placebo tablets and tablets containing the active ingredient itself. During the active coating Raman spectra were recorded in-line. The spectral measurements were correlated with the average weight gain and the amount of coated active ingredient at each time point. The developed chemometric model was tested by monitoring further coated batches. Furthermore, the effects of pan rotation speed and working distance on the acquired Raman signal and, hence, resulting effect of the chemometric model were examined. RESULTS: Besides coating on placebo cores it was possible to determine the amount of active ingredient in the film when coated onto cores containing the same active ingredient. In addition, the method is even applicable when varying the process parameters and measurement conditions within a restricted range. CONCLUSION: Raman spectroscopy is an appropriate process analytical technology too.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multivariate data analysis in pharmaceutics: A tutorial review
Rajalahti, T., & Kvalheim, O. M. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.02.019 · Cited by 768
De Beer, T., Burggraeve, A., Fonteyne, M., Saerens, L., Remon, J. P., & Vervaet, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.012 · Cited by 559
Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332
“Raman has demonstrated value as an in-line PAT for batch or continuous tablet coating processes, providing both process control and real-time coating release [55, 56] and capable of meeting ICH Q2 guidelines for an active coating process [4].”
BackgroundSelf-citationRaman Spectroscopy for Process Analytical Technologies of Pharmaceutical Secondary Manufacturing
Nagy, B., Farkas, A., Borbás, E., Vass, P., Nagy, Z. K., & Marosi, G. (2019) · AAPS PharmSciTech · doi:10.1208/s12249-018-1201-2 · Cited by 89
Metadata
- Authors
- Müller, J., Knop, K., Thies, J., Uerpmann, C., & Kleinebudde, P.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 2010-01-13
- Volume
- 36
- Issue
- 2
- Pages
- 234-243
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2026034321
- Cited by
- 66
- References
- 0
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of Raman spectroscopy as PAT tool in active coating. https://app.cochat.ai/papers/10.3109/03639040903225109
- The paper
- Müller, J., Knop, K., Thies, J., Uerpmann, C., & Kleinebudde, P. (2010). Feasibility of Raman spectroscopy as PAT tool in active coating. Drug Development and Industrial Pharmacy. https://doi.org/10.3109/03639040903225109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.