Gelatin-Poly(Ethylene Oxide) Semi-interpenetrating Polymer Network with pH-Sensitive Swelling and Enzyme-Degradable Properties for Oral Drug Delivery
The DOI matches its Crossref record.
Abstract
The study examined the effect of poly(ethylene oxide) (PEO) molecular weight and concentration in a gelatin-PEO semi-interpenetrating polymer network (semi-IPN) on the swelling behavior and enzyme-induced degradation in simulated gastric fluid (SGF, pH 1.2) and simulated intestinal fluid (SIF, pH 7.2) at 37°C. Gelatin-PEO semi-IPN with PEO of molecular weight 1,000,000 daltons (1.0 M) at 20% (w/w) concentration had a higher swelling ratio in SGF as compared to SIF. In addition, the pH-sensitive swelling behavior was influenced by the concentration of incorporated PEO of 1.0 M molecular weight in the semi-IPN. The time required for complete hydrogel degradation in pepsin-containing SGF and pancreatin-containing SIF by surface erosion was also dependent on the molecular weight and concentration of PEO. Complete degradation of control gelatin hydrogels in SIF occurred in 2 hr. In contrast, complete degradation of gelatin-PEO semi-IPN in pancreatin-containing SIF occurred in less than 1 hr. Although no difference in riboflavin release kinetics was observed between gelatin and gelatin-PEO hydrogels, there was a marked effect in drug release in the presence of enzymes. In pancreatin-containing SIF, for instance, the total riboflavin load was released in 8 hr from gelatin-PEO semi-IPN. Surface degradation of the hydrogel decreases the diffusional path length of the drug for faster release as the gel degrades. By varying the PEO molecular weight and amount in gelatin-PEO semi-IPN, it is possible to design hydrogels for site-specific oral delivery in the stomach and upper intestine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Hydrogels: From controlled release to pH-responsive drug delivery
Gupta, P., Vermani, K., & Garg, S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02255-9 · Cited by 1,825
Chronobiology, drug delivery, and chronotherapeutics
Smolensky, M. H., & Peppas, N. A. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.07.001 · Cited by 288
Chatterjee, S., Hui, P. C.-L., & Kan, C.-W. (2018) · Polymers · doi:10.3390/polym10050480 · Cited by 196
“Drug delivery systems of pH-responsive hydrogels made from some polymers and their composites like chitosan-poly(ethylene oxide) for amoxicillin, metronidazole [199], gelatin-poly(ethylene oxide) for riboflavin [200], poly(acrylamide-co-maleic acid) for terbinafine hydrochloride [201], poly(2-hydroxyethyl methacrylate…”
BackgroundSingh, B., Sharma, N., & Chauhan, N. (2007) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2007.01.020 · Cited by 95
Metadata
- Authors
- Amiji, M., Tailor, R., Ly, M.-K., & Goreham, J.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 1997-01
- Volume
- 23
- Issue
- 6
- Pages
- 575-582
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2122143791
- Cited by
- 32
- References
- 0
- FWCI
- 0.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gelatin-Poly(Ethylene Oxide) Semi-interpenetrating Polymer Network with pH-Sensitive Swelling and Enzyme-Degradable Properties for Oral Drug Delivery. https://app.cochat.ai/papers/10.3109/03639049709149822
- The paper
- Amiji, M., Tailor, R., Ly, M.-K., & Goreham, J. (1997). Gelatin-Poly(Ethylene Oxide) Semi-interpenetrating Polymer Network with pH-Sensitive Swelling and Enzyme-Degradable Properties for Oral Drug Delivery. Drug Development and Industrial Pharmacy. https://doi.org/10.3109/03639049709149822
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.