Cited by 523D Printing in Biomedical ResearchCellular Mechanics and InteractionsMicrofluidic and Capillary Electrophoresis Applications

The DOI matches its Crossref record; 213 of the 214 references it cites were found in a registry or an index.

Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces

Ben-Yoav, Hadar, Melamed, Sahar, Freeman, Amihay, Shacham-Diamand, Yosi, Belkin, Shimshon·2011·Critical Reviews in Biotechnology

Abstract

Recent advances in the convergence of the biological, chemical, physical, and engineering sciences have opened new avenues of research into the interfacing of diverse biological moieties with inanimate platforms. A main aspect of this field, the integration of live cells with micro-machined platforms for high throughput and bio-sensing applications, is the subject of the present review. These unique hybrid systems are configured in a manner that ensures positioning of the cells in designated patterns, and enables cellular viability maintenance, and monitoring of cellular functionality. Here we review both animate and inanimate surface properties and how they affect cellular attachment, describe relevant modifications of both types of surfaces, list technologies for platform engineering and for cell deposition in the desired configurations, and discuss the influence of various deposition and immobilization methods on the viability and performance of the immobilized cells.

Overview

Integrity signals

Registry

Crossref · 10.3109/07388551.2010.532767

Cites

213 of 213 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Items 201–213 of 213

Research works printed but not linked: 11

  1. Brandenburg A, 2009, Adv Biomed Clin Diagn Syst VII
  2. Colpo P, 2010, Adv Biochem Engin/Biotechnol, 117, 109
  3. Date A, 2010, Adv Biochem Eng / Biotechnol, 117, 57
  4. Kintzios SE., 2006, Front Drug Des Discov, 2, 225
  5. Melamed S, 2010, Lab on a Chip
  6. Muller R, 2007, J Biomed Mater Res A, 84, 817
  7. Parviz M, 2007, Neuro Toxicology, 28, 520
  8. Shimomura-Shimizu M, 2010, Adv Biochem Eng/Biotechnol, 118, 1
  9. Sze SM. (1988). VLSI technology. New York, McGraw-Hill.
  10. Van der Meer JR, 2010, Annu Rev Microbiol, 8
  11. Yasuda H., 1981, J Polym Sci: Macromol Rev, 16, 199

Cited by

Sorted by citations

See all 52

Metadata

Authors
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S.
Affiliations
  • Hebrew University of Jerusalem (IL)
  • Tel Aviv University (IL)
Venue
Critical Reviews in Biotechnology
Published
2010-12-30
Volume
31
Issue
4
Pages
337-353
ISSN
  • 0738-8551 (ISSN-L)
  • 1549-7801
OpenAlex
W1969803714
Cited by
52
References
214
Citations by year
2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 6 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 4 · 2014: 8 · 2013: 7 · 2012: 7
FWCI
0.47
Type
journal article
Language
en
Open access
closed
Locations
  • Critical Reviews in Biotechnology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
biosensing, cell patterning, cell-surface interactions, surface modification, cell viability
MeSH terms
Bacteria, Cell Adhesion, Cell Survival, Surface Properties, Biosensing Techniques, Cells, Immobilized, Microfluidic Analytical Techniques, Microarray Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review