Reliability of shoulder range of motion comparing a goniometer to a digital level
Abstract
The clinical use of digital levels, for joint measurement, may be a viable alternative to standard goniometry. The purpose of this study was to determine the intra- and intertester reliability of a construction grade digital level compared to the standard universal goniometer for measurements for active assisted shoulder range of motion (ROM). Two experienced physical therapists measured shoulder flexion, external rotation (ER), and internal rotation (IR) ROM bilaterally, on two different occasions, in 20 patients (9 males, 11 females, 18-79 years old) with unilateral shoulder pathology, using a goniometer and a digital level. Relative reliability was assessed by using intraclass correlation coefficients (ICC), and absolute reliability was assessed by using 95% limits of agreement (LOA). Intratester ICCs ranged from 0.91 to 0.99, and LOA ranged from 3 degrees to 9 degrees for measurements made with the goniometer and digital level. Intertester ICCs ranged from 0.31 to 0.95, and LOA ranged from 6 degrees to 25 degrees . For the comparison of goniometric vs. digital level ROM, ICCs ranged from 0.71 to 0.98. ER and IR ROM were 3-5 degrees greater for the digital level than the goniometer (p < 0.01). Goniometric vs. digital level LOA ranged from 6 degrees to 11 degrees for shoulder flexion. Both measurement techniques had excellent intratester reliability, but for intertester reliability ICCs were 20% lower and LOA were 2.3 times higher than intratester values. Reliability estimates were similar between the digital level and the goniometer. However, because glenohumeral rotation was 3-5 degrees greater for the digital level than the goniometer (systematic error), the two methods cannot be used interchangeably. On the basis of the average intratester LOA for the goniometer and the digital level, a change of 6-11 degrees is needed to be certain that true change has occurred. For comparison of measures made by two different therapists, a change is of 15 degrees is required to be certain a true change has occurred. A digital level can be used to reliably measure shoulder ROM but should not be used interchangeably with a standard goniometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Archives of Physical Medicine and Rehabilitation
(1976) · Journal of Sound and Vibration · doi:10.1016/0022-460x(76)90695-7 · Cited by 5,476
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Journal of Strength and Conditioning Research: Among the Best News You Can Use
Koziris, L. P. (2003) · Strength and Conditioning Journal · doi:10.1519/00126548-200302000-00014 · Cited by 1,579
Measurement of Joint Motion: A guide to goniometry
Norkin, C. C., & White, D. (1985) · Medical Entomology and Zoology · Cited by 1,118
Clinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 898
Foundations of clinical research. Applications to practice
Fortney, L. (1993) · Medical Entomology and Zoology · Cited by 701
Reliability of Goniometric Measurements
Boone, D. C., Azen, S. P., Lin, C.-M., Spence, C., Baron, C., & Lee, L. (1978) · Physical Therapy · doi:10.1093/ptj/58.11.1355 · Cited by 560
Goniometric Reliability in a Clinical Setting
Rothstein, J. M., Miller, P. J., & Roettger, R. F. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1611 · Cited by 546
Reliability of five methods for assessing shoulder range of motion
Hayes, K., Walton, J. R., Szomor, Z. L., & Murrell, G. A. (2001) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60274-9 · Cited by 402
Cited by
Clarsen, B., Bahr, R., Andersson, S. H., Munk, R., & Myklebust, G. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093702 · Cited by 359
Cools, A. M., De Wilde, L., Van Tongel, A., Ceyssens, C., Ryckewaert, R., & Cambier, D. C. (2014) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2014.01.006 · Cited by 284
Dominguez-Romero, J. G., Jiménez-Rejano, J. J., Ridao-Fernández, C., & Chamorro-Moriana, G. (2021) · Diagnostics · doi:10.3390/diagnostics11030529 · Cited by 36
“Few authors used manual goniometers, which imply a certain subjectivity, but, when used correctly by experts, minimise bias [83,84].”
Soylu, C., Acar, G., Uzumcu, B., Demir, P., Seyhan, S., & Biyikli, T. (2025) · Life · doi:10.3390/life15010080 · Cited by 7
Metadata
- Authors
- Mullaney, M. J., McHugh, M. P., Johnson, C. P., & Tyler, T. F.
- Venue
- Physiotherapy Theory and Practice
- Publisher
- Informa UK Limited
- Published
- 2010-06-17
- Volume
- 26
- Issue
- 5
- Pages
- 327-333
- ISSN
- 0959-3985 (ISSN-L)
- 1532-5040
- OpenAlex
- W2130300989
- Cited by
- 265
- References
- 19
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of shoulder range of motion comparing a goniometer to a digital level. https://app.cochat.ai/papers/10.3109/09593980903094230
- The paper
- Mullaney, M. J., McHugh, M. P., Johnson, C. P., & Tyler, T. F. (2010). Reliability of shoulder range of motion comparing a goniometer to a digital level. Physiotherapy Theory and Practice. https://doi.org/10.3109/09593980903094230
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.