Test-Retest Reliability and Validity of TecnoBody D-Wall to Assess the Range of Motion During Overhead Squat in Healthy Individuals
Open accessAbstract
This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.66 years were included. Measurements were conducted for hip and knee joint angles in the sagittal plane, with three repetitions per participant analyzed using both systems. The D-Wall system employed a 3D Kinect V2 camera and force platform, while Kinovea used 2D video-based motion analysis. The results demonstrated excellent agreement between the two systems, with intra-class correlation coefficients (ICC) ranging from 0.79 to 0.99. For the knee joint, the test-retest ICC values were 0.99 (95% CI: 0.97–0.99) for Kinovea and 0.98 (95% CI: 0.95–0.99) for the D-Wall on the right side, and 0.98 (95% CI: 0.97–0.99) for Kinovea and 0.88 (95% CI: 0.79–0.94) for the D-Wall on the left side. For the hip joint, test-retest ICC values were 0.99 (95% CI: 0.97–0.99) for Kinovea and 0.94 (95% CI: 0.88–0.97) for the D-Wall on the right side, and 0.98 (95% CI: 0.97–0.99) for Kinovea and 0.93 (95% CI: 0.87–0.97) for the D-Wall on the left side. Bland–Altman plots confirmed good agreement, with no significant systematic bias observed. Both systems showed statistically insignificant differences (p > 0.05) between measurements, and correlation values ranged from 0.83 to 0.99, indicating strong associations. These findings highlight the high validity and reliability of both TecnoBody D-Wall and Kinovea systems in measuring joint angles during dynamic movements. The comparable accuracy between systems suggests that either system can be effectively utilized in clinical or research settings, depending on specific needs and resource availability.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In our study, knee flexion showed an almost identical ICC (0.98 vs. 0.99) to Soylu et al., but with a significantly lower SEM (1.98° vs. 6.06°).
“In our study, knee flexion showed an almost identical ICC (0.98 vs. 0.99), but with a significantly lower SEM (1.98° vs. 6.06°).”
From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as [58]
The Abstract reports a knee test–retest ICC of 0.99 for right-side Kinovea measurements, supporting the ICC comparison. The Results discuss measurement errors and refer to Table 3, but the passages available in our copy do not give a knee SEM of 6.06°; the claimed SEM value and significance of the cross-study difference therefore cannot be verified from this source. (LLM, conf=0.83)
Experimental — accuracy not yet measuredSoylu et al., comparing Kinovea with the D-Wall system in the overhead squat, obtained ICCs in the sagittal plane ranging from 0.79 to 0.99.
“Soylu et al. [58], who, when comparing Kinovea with the D-Wall system in the overhead squat, obtained ICCs in the sagittal plane ranging from 0.79 to 0.99.”
From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as [58]
For hip flexion, we obtained an ICC of 0.82 compared to 0.99 reported by Soylu et al.
“for hip flexion, we obtained an ICC of 0.82 compared to 0.99 reported by Soylu et al.”
From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as [58]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 29,639 · see citing works
Statistics corner: A guide to appropriate use of correlation coefficient in medical research.
(2012) · Europe PMC (PubMed Central) · Cited by 4,239 · see citing works
Bujang, M. A., & Baharum, N. (2017) · Archives of Orofacial Sciences · Cited by 456 · see citing works
Puig-Diví, A., Escalona-Marfil, C., Padullés-Riu, J. M., Busquets, A., Padullés-Chando, X., & Marcos-Ruiz, D. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216448 · Cited by 434 · see citing works
Reliability of shoulder range of motion comparing a goniometer to a digital level
Mullaney, M. J., McHugh, M. P., Johnson, C. P., & Tyler, T. F. (2010) · Physiotherapy Theory and Practice · doi:10.3109/09593980903094230 · Cited by 266 · see citing works
Milanese, S., Gordon, S. J., Buettner, P. G., Flavell, C. A., Ruston, S., Coe, D., O'Sullivan, W., & McCormack, S. (2014) · Manual Therapy · doi:10.1016/j.math.2014.05.009 · Cited by 196 · see citing works
Fernández-González, P., Koutsou, A., Cuesta-Gómez, A., Carratalá-Tejada, M., Miangolarra-Page, J. C., & Molina-Rueda, F. (2020) · Sensors · doi:10.3390/s20113154 · Cited by 185 · see citing works
Keogh, J., Cox, A., Anderson, S., Liew, B. X. W., Olsen, A., Schram, B. L., & Furness, J. W. (2019) · PLoS ONE · doi:10.1371/journal.pone.0215806 · Cited by 159 · see citing works
Ellis, B., Bruton, A., & Goddard, J. R. (1997) · Clinical Rehabilitation · doi:10.1177/026921559701100408 · Cited by 89 · see citing works
Reliability of video-based quantification of the knee- and hip angle at foot strike during running.
Damsted, C., Nielsen, R. O., & Larsen, L. H. (2015) · PubMed Central · Cited by 89 · see citing works
Footstrike patterns among novice runners wearing a conventional, neutral running shoe
Bertelsen, M. L., Jensen, J. F., Nielsen, M., Nielsen, R. O., & Rasmussen, S. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.11.022 · Cited by 63 · see citing works
McVeigh, K. H., Murray, P. M., Heckman, M. G., Rawal, B., & Peterson, J. J. (2016) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2015.12.014 · Cited by 61 · see citing works
Krause, D. A., Boyd, M. S., Hager, A. N., Smoyer, E. C., Thompson, A. T., & Hollman, J. H. (2015) · Europe PMC (PubMed Central) · Cited by 53 · see citing works
Sañudo, B., Rueda, D., Cruz, B. D. P., Lora, M. D. H., & Páez, L. C. (2014) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000563 · Cited by 47 · see citing works
Damsted, C., Larsen, L. H., & Nielsen, R. O. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.01.029 · Cited by 39 · see citing works
Tajali, S. B., MacDermid, J. C., Grewal, R. S., & Young, C. (2016) · The Open Orthopaedics Journal · doi:10.2174/1874325001610010190 · Cited by 35 · see citing works
Youssef, A. R. (2016) · International Journal of Physiotherapy · doi:10.15621/ijphy/2016/v3i3/100838 · Cited by 34 · see citing works
Russo, R. R., Burn, M. B., Ismaily, S. K., Gerrie, B. J., Han, S., Alexander, J. W., Lenherr, C., Noble, P. C., Harris, J. D., & McCulloch, P. C. (2017) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-017-0103-7 · Cited by 28 · see citing works
A webcam-based machine learning approach for three-dimensional range of motion evaluation
Wang, X. M., Smith, D. T., & Zhu, Q. (2023) · PLoS ONE · doi:10.1371/journal.pone.0293178 · Cited by 23 · see citing works
Bravi, M., Massaroni, C., Santacaterina, F., Tocco, J. D., Schena, E., Sterzi, S., Bressi, F., & Miccinilli, S. (2021) · Sensors · doi:10.3390/s21144795 · Cited by 22 · see citing works
Validity of the MarkWiiR for kinematic analysis during walking and running gaits
Padulo, J., Vando, S., Chamari, K., Chaouachi, A., Bagno, D., & Pizzolato, F. (2014) · Biology of Sport · doi:10.5604/20831862.1127282 · Cited by 20 · see citing works
Clinical Reliability and Usability of Smartphone Goniometers for Hip Range of Motion Measurement
Takeda, Y., & Furukawa, K. (2022) · Journal of Physical Therapy Science · doi:10.1589/jpts.34.433 · Cited by 10 · see citing works
Investigation of the Effectiveness of TecnoBody Devices in Rehabilitation
Üzümcü, B., Açar, G., Konakoğlu, G., & Mutuş, R. (2024) · İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi · doi:10.38079/igusabder.1418692 · Cited by 9 · see citing works
webcam-based machine learning approach for three-dimensional range of motion evaluationPreprint
Wang, X. M., Smith, D., & Zhu, Q. (2022) · doi:10.51224/srxiv.219 · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Omidi, H., Rad, R. S., & Ghorbani, M. (2025) · Journal of Sport Biomechanics · doi:10.61882/jsportbiomech.11.4.424 · Cited by 2 · see citing works
Vicente-Loren, C., Lucha-López, M. O., Monti-Ballano, S., Hijazo-Larrosa, S., Vicente-Pina, L., Ferrández-Laliena, L., Tricás-Moreno, J. M., & Hidalgo-García, C. (2026) · Sensors · doi:10.3390/s26123749
Seemab, A., Watson Arulsingh, D. R., Muthukrishnan, R., Kandakurti, P. K., & Saiyad, R. (2026) · Trials · doi:10.1186/s13063-026-09661-z
Açar, G., Başer, M., Özkeskin, M., Özden, F., Seyhan, S., Kavak, M. F., Sarı, Z., & Aktürk, A. (2026) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2026.107225
Self-citationAguiló-Furio, J., Tronchoni-Crespo, B., Olmedo-Reillo, J., Guerra-Armas, J., Agustín, F. J. M.-S., & Agustín, R. M. (2026) · European Journal of Physiotherapy · doi:10.1080/21679169.2026.2693306
Accessible 2D video-based system for gait kinematic analysis: an inter-rater reliability study
Puig-Diví, A., Costa‐Tutusaus, L., García-Gil, J., Sartori, F., & Picañol, J. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1815411
la Cruz, S. P., Rueda, F. M., & Fernández-González, P. (2026) · Sensors · doi:10.3390/s26196229
- Authors
- Soylu, C., Acar, G., Uzumcu, B., Demir, P., Seyhan, S., & Biyikli, T.
- Affiliations
- Gulhane Faculty of Physiotherapy and Rehabilitation, University of Health Sciences, 06010 Ankara, Turkey
- Department of Sport Science, Institute of Graduate Education, Manisa Celal Bayar University, 45040 Manisa, Turkey
- Berton Robotic Technology and Health Inc., 34720 Istanbul, Turkey
- Biostatistics and Medical Informatics, Basic Medical Sciences, Faculty of Medicine, Ankara Yildirim Beyazit University, 06145 Ankara, Turkey
- Manisa Celal Bayar University (TR)
- Department of Coaching Education, Marmara University Faculty of Sport Sciences, 34815 Istanbul, Turkey
- Venue
- Life
- Publisher
- MDPI AG
- Published
- 2025-01-10
- Volume
- 15
- Issue
- 1
- Pages
- 80
- ISSN
- 2075-1729 (ISSN-L)
- PMC
- PMC11766738
- OpenAlex
- W4406244435
- Cited by
- 7
- References
- 23
- Citations by year
- 2026: 6 · 2025: 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Life (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- AYBU AVESIS (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- overhead squat, range of motion, test-retest reliability, measurement validity, hip joint angle, knee joint angle, 3D motion capture, Kinovea video analysis, sagittal plane, healthy individuals, Bland-Altman agreement, force plate, sports biomechanics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review