Cited by 7Lower Extremity Biomechanics and PathologiesSports Performance and TrainingSports Dynamics and Biomechanics

Test-Retest Reliability and Validity of TecnoBody D-Wall to Assess the Range of Motion During Overhead Squat in Healthy Individuals

Open access
Soylu, Caglar, Acar, Gorkem, Uzumcu, Berkay, Demir, Pervin, Seyhan, Sinan, Biyikli, Turker·2025·Life

Abstract

This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.66 years were included. Measurements were conducted for hip and knee joint angles in the sagittal plane, with three repetitions per participant analyzed using both systems. The D-Wall system employed a 3D Kinect V2 camera and force platform, while Kinovea used 2D video-based motion analysis. The results demonstrated excellent agreement between the two systems, with intra-class correlation coefficients (ICC) ranging from 0.79 to 0.99. For the knee joint, the test-retest ICC values were 0.99 (95% CI: 0.97–0.99) for Kinovea and 0.98 (95% CI: 0.95–0.99) for the D-Wall on the right side, and 0.98 (95% CI: 0.97–0.99) for Kinovea and 0.88 (95% CI: 0.79–0.94) for the D-Wall on the left side. For the hip joint, test-retest ICC values were 0.99 (95% CI: 0.97–0.99) for Kinovea and 0.94 (95% CI: 0.88–0.97) for the D-Wall on the right side, and 0.98 (95% CI: 0.97–0.99) for Kinovea and 0.93 (95% CI: 0.87–0.97) for the D-Wall on the left side. Bland–Altman plots confirmed good agreement, with no significant systematic bias observed. Both systems showed statistically insignificant differences (p > 0.05) between measurements, and correlation values ranged from 0.83 to 0.99, indicating strong associations. These findings highlight the high validity and reliability of both TecnoBody D-Wall and Kinovea systems in measuring joint angles during dynamic movements. The comparable accuracy between systems suggests that either system can be effectively utilized in clinical or research settings, depending on specific needs and resource availability.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/life15010080

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Soylu, C., Acar, G., Uzumcu, B., Demir, P., Seyhan, S., & Biyikli, T.
Affiliations
  • Gulhane Faculty of Physiotherapy and Rehabilitation, University of Health Sciences, 06010 Ankara, Turkey
  • Department of Sport Science, Institute of Graduate Education, Manisa Celal Bayar University, 45040 Manisa, Turkey
  • Berton Robotic Technology and Health Inc., 34720 Istanbul, Turkey
  • Biostatistics and Medical Informatics, Basic Medical Sciences, Faculty of Medicine, Ankara Yildirim Beyazit University, 06145 Ankara, Turkey
  • Manisa Celal Bayar University (TR)
  • Department of Coaching Education, Marmara University Faculty of Sport Sciences, 34815 Istanbul, Turkey
Venue
Life
Publisher
MDPI AG
Published
2025-01-10
Volume
15
Issue
1
Pages
80
ISSN
2075-1729 (ISSN-L)
OpenAlex
W4406244435
Cited by
7
References
23
Citations by year
2026: 6 · 2025: 1
FWCI
1.70
Type
journal article
Language
en
Open access
Locations
  • Life (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • AYBU AVESIS (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
Keywords
overhead squat, range of motion, test-retest reliability, measurement validity, hip joint angle, knee joint angle, 3D motion capture, Kinovea video analysis, sagittal plane, healthy individuals, Bland-Altman agreement, force plate, sports biomechanics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review