A New Method for Continuous Chronic Measurement and Recording of Blood Pressure, Heart Rate and Activity in the Rat Via Radio-telemetry
The DOI matches its Crossref record.
Abstract
Accurate continuous chronic measurements of blood pressure from conscious laboratory rats are critical to many experimental protocols but have been difficult or impossible to acquire. A system consisting of an implantable radio-telemetry device, receiver, and computer-based data acquisition system that allows such measurements to be easily obtained has been developed. This system is capable of monitoring and recording arterial pressure (waveform, systolic, diastolic, and mean), heart rate, and activity from rats weighing greater than 175 gm for periods in excess of 6 months. Chronic patency has been achieved through a patented design which includes an antithrombogenic film and a gel membrane located at the catheter tip. Validation of telemetered measurements via carotid catheter has demonstrated the accuracy to be better than +/- 5 mmHg in 85% (N = 20) tested at 3 weeks post implantation, 86% (N = 15) tested at 8 weeks, and 78% (N = 9) at 12 weeks. Incidence of loss of patency was 2.3% (N = 44). This system has a demonstrated ability to obtain accurate continuous chronic measurements of arterial pressure free of the stressors associated with conventional systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Sex differences in primary hypertension
Sandberg, K., & Ji, H. (2012) · Biology of Sex Differences · doi:10.1186/2042-6410-3-7 · Cited by 442
Li, Z., Zhang, Y., Ying Ma, J., Kapoun, A. M., Shao, Q., Kerr, I., Lam, A., O’Young, G., Sannajust, F., Stathis, P., et al. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.092098 · Cited by 260
Evaluation and applications of radiotelemetry in small laboratory animals
Kramer, K., & Kinter, L. B. (2003) · Physiological Genomics · doi:10.1152/physiolgenomics.00164.2002 · Cited by 221
“In freely moving mice and rats equipped with cardiovascular radiotelemetry transmitters and monitored in their home cages, HR and BP values were found to be much lower compared with published values (8, 10, 47, 49, 50, 77).”
ResultAMANN, K., RUMP, L. C., SIMONAVICIENE, A., OBERHAUSER, V., WESSELS, S., ORTH, S. R., GROSS, M.-L., KOCH, A., BIELENBERG, G. W., VAN KATS, J. P., et al. (2000) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1181469 · Cited by 192
Cong, P., Chaimanonart, N., Ko, W. H., & Young, D. J. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035551 · Cited by 190
Kurtz, T. W., Griffin, K. A., Bidani, A. K., Davisson, R. L., & Hall, J. E. (2005) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000158419.98675.d7 · Cited by 171
Tornatzky, W., & Miczek, K. A. (1994) · Psychopharmacology · doi:10.1007/bf02245339 · Cited by 168
“In the present investigation, we took advantage of a major methodological advance in the study of social stress, namely the application of telemetry devices for unconfounded physiological measurements in unrestrained laboratory rats (Bohus 1974; Kittrell and Satinoff 1988; Stoehr 1988; Brockway et al. 1991; Tornatzky…”
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
“[121] used a piezoresistive catheter inserted into the aorta of a rat to monitor ambulatory heart rate and blood pressure.”
MethodDiurnal variations of blood pressure in dogs.
MISHINA, M., WATANABE, T., MATSUOKA, S., SHIBATA, K., FUJII, K., MAEDA, H., & WAKAO, Y. (1999) · Journal of Veterinary Medical Science · doi:10.1292/jvms.61.643 · Cited by 29
Metadata
- Authors
- Brockway, B. P., Mills, P. A., & Azar, S. H.
- Venue
- Clinical and Experimental Hypertension. Part A: Theory and Practice
- Publisher
- Informa UK Limited
- Published
- 1991-01
- Volume
- 13
- Issue
- 5
- Pages
- 885-895
- ISSN
- 0148-3927 (ISSN-L)
- 0730-0077
- OpenAlex
- W2196751099
- Cited by
- 249
- References
- 0
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.