The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring
Abstract
An implantable real-time blood pressure monitoring microsystem for laboratory mice has been demonstrated. The system achieves a 10-bit blood pressure sensing resolution and can wirelessly transmit the pressure information to an external unit. The implantable device is operated in a batteryless manner, powered by an external RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The microsystem employs an instrumented silicone cuff, wrapped around a blood vessel with a diameter of approximately 200 ¿m, for blood pressure monitoring. The cuff is filled by low-viscosity silicone oil with an immersed MEMS capacitive pressure sensor and integrated electronic system to detect a down-scaled vessel blood pressure waveform with a scaling factor of approximately 0.1. The integrated electronic system, consisting of a capacitance-to-voltage converter, an 11-bit ADC, an adaptive RF powering system, an oscillator-based 433 MHz FSK transmitter and digital control circuitry, is fabricated in a 1.5 ¿m CMOS process and dissipates a power of 300 ¿W. The packaged microsystem weighs 130 milligram and achieves a capacitive sensing resolution of 75 aF over 1 kHz bandwidth, equivalent to a pressure sensing resolution of 1 mmHg inside an animal vessel, with a dynamic range of 60 dB. Untethered laboratory animalin vivoevaluation demonstrates that the microsystem can capture real-time blood pressure information with a high fidelity under an adaptive RF powering and wireless data telemetry condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Cited by
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Biopsy with Thermally‐Responsive Untethered Microtools
Gultepe, E., Randhawa, J. S., Kadam, S., Yamanaka, S., Selaru, F. M., Shin, E. J., Kalloo, A. N., & Gracias, D. H. (2013) · Advanced Materials · doi:10.1002/adma.201203348 · Cited by 271
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
A batteryless energy harvesting storage system for implantable medical devices demonstrated in situ
Gall, O. Z., Meng, C., Bhamra, H., Mei, H., John, S. W. M., & Irazoqui, P. P. (2019) · Circuits, Systems, and Signal Processing · doi:10.1007/s00034-018-0915-4 · Cited by 13
Metadata
- Authors
- Cong, P., Chaimanonart, N., Ko, W. H., & Young, D. J.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-12
- Volume
- 44
- Issue
- 12
- Pages
- 3631-3644
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2144374842
- Cited by
- 190
- References
- 1
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring. https://app.cochat.ai/papers/10.1109/jssc.2009.2035551
- The paper
- Cong, P., Chaimanonart, N., Ko, W. H., & Young, D. J. (2009). A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2009.2035551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.