A novel implantable catheter system with transcutaneous port for intermittent convection-enhanced delivery of carboplatin for recurrent glioblastoma
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
CONTEXT: Inadequate penetration of the blood-brain barrier (BBB) by systemically administered chemotherapies including carboplatin is implicated in their failure to improve prognosis for patients with glioblastoma. Convection-enhanced delivery (CED) of carboplatin has the potential to improve outcomes by facilitating bypass of the BBB. OBJECTIVE: We report the first use of an implantable CED system incorporating a novel transcutaneous bone-anchored port (TBAP) for intermittent CED of carboplatin in a patient with recurrent glioblastoma. MATERIALS AND METHODS: The CED catheter system was implanted using a robot-assisted surgical method. Catheter targeting accuracy was verified by performing intra-operative O-arm imaging. The TBAP was implanted using a skin-flap dermatome technique modeled on bone-anchored hearing aid surgery. Repeated infusions were performed by attaching a needle administration set to the TBAP. Drug distribution was monitored with serial real-time T2-weighted magnetic resonance imaging (MRI). RESULTS: All catheters were implanted to within 1.5 mm of their planned target. Intermittent infusions of carboplatin were performed on three consecutive days and repeated after one month without the need for further surgical intervention. Infused volumes of 27.9 ml per day were well tolerated, with the exception of a single seizure episode. Follow-up MRI at eight weeks demonstrated a significant reduction in the volume of tumor enhancement from 42.6 ml to 24.6 ml, and was associated with stability of the patient's clinical condition. CONCLUSION: Reduction in the volume of tumor enhancement indicates that intermittent CED of carboplatin has the potential to improve outcomes in glioblastoma. The novel technology described in this report make intermittent CED infusion regimes an achievable treatment strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bogdahn, U., Hau, P., Stockhammer, G., Venkataramana, N. K., Mahapatra, A. K., Suri, A., Balasubramaniam, A., Nair, S., Oliushine, V., Parfenov, V., et al. (2011) · Neuro-Oncology · doi:10.1093/neuonc/noq142 · Cited by 433 · cited 2×
“been restricted to either single infusions or continuous slow infusions over a number of days using implantable or ambulatory pumps (Bogdahn et al., 2011; Bruce et al., 2011; Mueller et al., 2011).”
Background
Cited by
Whone, A., Luz, M., Boca, M., Woolley, M., Mooney, L., Dharia, S., Broadfoot, J., Cronin, D., Schroers, C., Barua, N. U., et al. (2019) · Brain · doi:10.1093/brain/awz023 · Cited by 282
Self-citationHarnessing cerebrospinal fluid circulation for drug delivery to brain tissues
Naseri Kouzehgarani, G., Feldsien, T., Engelhard, H. H., Mirakhur, K. K., Phipps, C., Nimmrich, V., Clausznitzer, D., & Lefebvre, D. R. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.03.002 · Cited by 95
Hosseinpour, A., Soltani, M., & Souri, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-52003-9 · Cited by 53
“However, depending on the therapeutic agent and tumor tissue, the injection time can vary from a few minutes to several days 3,41–44 .”
Background
Metadata
- Authors
- Barua, N. U., Hopkins, K., Woolley, M., O’Sullivan, S., Harrison, R., Edwards, R. J., Bienemann, A. S., Wyatt, M. J., Arshad, A., & Gill, S. S.
- Venue
- Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2014-05-02
- Volume
- 23
- Issue
- 1
- Pages
- 167-173
- ISSN
- 1071-7544 (ISSN-L)
- 1521-0464
- OpenAlex
- W2107160883
- Cited by
- 74
- References
- 1
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel implantable catheter system with transcutaneous port for intermittent convection-enhanced delivery of carboplatin for recurrent glioblastoma. https://app.cochat.ai/papers/10.3109/10717544.2014.908248
- The paper
- Barua, N. U., Hopkins, K., Woolley, M., O’Sullivan, S., Harrison, R., Edwards, R. J., Bienemann, A. S., Wyatt, M. J., Arshad, A., & Gill, S. S. (2016). A novel implantable catheter system with transcutaneous port for intermittent convection-enhanced delivery of carboplatin for recurrent glioblastoma. Drug Delivery. https://doi.org/10.3109/10717544.2014.908248
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.