Paliperidone microemulsion for nose-to-brain targeted drug delivery system: pharmacodynamic and pharmacokinetic evaluation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective of present study was to develop and evaluate paliperidone (PALI) loaded microemulsion (PALI-ME) for intranasal delivery in the treatment of schizophrenia. MATERIAL AND METHODS: The PALI-ME was formulated by the spontaneous microemulsification method and characterized for physicochemical parameters. Pharmacodynamic assessments (apomorphine-induced compulsive behavior and spontaneous motor activity) were performed using mice. All formulations were tagged with (99m)Tc (technetium). Pharmacokinetic evaluation of PALI in the brain was investigated using Swiss albino rats. Brain scintigraphy imaging was performed in rabbits. RESULTS AND DISCUSSION: PALI-ME was found stable with average droplet size of 20.01 ± 1.28 nm. In pharmacodynamic studies, significant (p < 0.05) deference in parameters estimated, were found between the treated and control groups. (99m)Tc-tagged PALI solution (PALI-SOL)/PALI-ME/PALI muco-adhesive ME (PALI-MME) was found to be stable and suitable for in vivo studies. Brain-to-blood ratio at all sampling points up to 8 h following intranasal administration of PALI-MME compared to intravenous PALI-ME was found to be 6-8 times higher signifying greater extent of distribution of the PALI in brain. Rabbit brain scintigraphy demonstrated higher intranasal uptake of the PALI into the brain. CONCLUSION: This investigation demonstrates a prompt and larger extent of transport of PALI into the brain through intranasal PALI-MME, which may prove beneficial for treatment of schizophrenia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoemulsion-based intranasal drug delivery system of saquinavir mesylate for brain targeting
Mahajan, H. S., Mahajan, M. S., Nerkar, P. P., & Agrawal, A. (2014) · Drug Delivery · doi:10.3109/10717544.2013.838014 · Cited by 212
Cited by
Nanosystems in nose-to-brain drug delivery: A review of non-clinical brain targeting studies
Pires, P. C., & Santos, A. O. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.047 · Cited by 228
Progress in nasal drug delivery systems
Laffleur, F., & Bauer, B. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120994 · Cited by 189
Intranasal drug delivery: The interaction between nanoparticles and the nose-to-brain pathway
Chen, Y., Zhang, C., Huang, Y., Ma, Y., Song, Q., Chen, H., Jiang, G., & Gao, X. (2024) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2024.115196 · Cited by 172
Zorkina, Y., Abramova, O., Ushakova, V., Morozova, A., Zubkov, E., Valikhov, M., Melnikov, P., Majouga, A., & Chekhonin, V. (2020) · Molecules · doi:10.3390/molecules25225294 · Cited by 158
Wu, H., Zhou, Y., Wang, Y., Tong, L., Wang, F., Song, S., Xu, L., Liu, B., Yan, H., & Sun, Z. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.717192 · Cited by 90
Metadata
- Authors
- Patel, M. R., Patel, R. B., Bhatt, K. K., Patel, B. G., & Gaikwad, R. V.
- Venue
- Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2014-05-28
- Volume
- 23
- Issue
- 1
- Pages
- 346-354
- ISSN
- 1071-7544 (ISSN-L)
- 1521-0464
- OpenAlex
- W2008870667
- Cited by
- 67
- References
- 1
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.