Effect of Healing on Small Internal Diameter Arterial Graft Compliance
Abstract
Porosity is an essential component for long term function of small internal diameter synthetic vascular prostheses. Theoretically, porosity is required for healing by providing a scaffold for ingrowth of periprosthetic tissues. Porosity may be required for transfer of fluids and ions in prostheses even if tissue ingrowth does not occur. Increased permeability of vascular grafts has been shown to enhance tissue incorporation. Implants with pore sizes greater than 10 microns but less than 45 microns become ingrown with fibrohistiocytic tissue and capillaries. Implants with pore sizes greater than 45 microns are ingrown with organized fibrous tissue and minimal histiocytic response. The phenomenon of differential ingrowth may have important functional significance. Prostheses which heal with organized fibrous tissue have the potential for long term contracture, strangulation of vascularity and calcification. Fibrohistiocytic tissue has low mechanical strength and does not appear to contract or calcify. Elastomeric microporous vascular prostheses which are minimally ingrown or ingrown with fibrohistiocytic tissue maintain compliance after months of implantation. This study was designated to determine the effects of healing on the compliance of small internal diameter vascular replacements and to correlate the compliance to patency rates.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These earlier studies used materials with broad pore-size distributions (only average pore size was reported), making conclusions about the effects of pore size difficult.
“These earlier studies used materials with broad pore-size distributions (only average pore size was reported), making conclusions about the effects of pore size difficult.”
From Proangiogenic scaffolds as functional templates for cardiac tissue engineering (2010) · cites this paper as [31]
Pore size effects observed here relate to previous studies in which 10- to 45-μm pores filled with fibrohistiocytic tissue, whereas pores >45 μm filled with organized fibrous tissue.
“Pore size effects observed here relate to previous studies in which 10- to 45-μm pores filled with fibrohistiocytic tissue, whereas pores >45 μm filled with organized fibrous tissue (31, 32).”
From Proangiogenic scaffolds as functional templates for cardiac tissue engineering (2010) · cites this paper as [31]
Cites
Matched Elastic Properties and Successful Arterial Grafting
Walden, R. (1980) · Archives of Surgery · doi:10.1001/archsurg.1980.01380100018004 · Cited by 240 · see citing works
Histopathologic observations after short-term implantation of two porous elastomers in dogs
White, R. A., Hirose, F. M., Sproat, R. W., Lawrence, R. S., & Nelson, R. J. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90046-6 · Cited by 87 · see citing works
Self-citationGraft materials in vascular surgery
Dardik, H. (1978) · Medical Entomology and Zoology · Cited by 75 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Proangiogenic scaffolds as functional templates for cardiac tissue engineering
Madden, L. R., Mortisen, D. J., Sussman, E. M., Dupras, S. K., Fugate, J. A., Cuy, J. L., Hauch, K. D., Laflamme, M. A., Murry, C. E., & Ratner, B. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006442107 · Cited by 662 · see citing works
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.01.006 · Cited by 301 · see citing works
Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow
Stewart, S. F. C., & Lyman, D. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90027-x · Cited by 124 · see citing works
Factors and Interactions Affecting the Performance of Polyurethane Elastomers in Medical Devices
Coury, A. J., Slaikeu, P. C., Cahalan, P. T., Stokes, K., & Hobot, C. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300202 · Cited by 93 · see citing works
Trubel, W., Schima, H., Moritz, A., Raderer, F., Windisch, A., Ullrich, R., Windberger, U. B., Losert, U. M., & Polterauer, P. (1995) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(05)80163-7 · Cited by 80 · see citing works
Anisotropic tensile viscoelastic properties of vascular graft materials tested at low strain rates
Lee, J. M., & Wilson, G. J. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90029-3 · Cited by 70 · see citing works
Effects of an Artery/Vascular Graft Compliance Mismatch on Protein Transport: A Numerical Study
Stewart, S. F. C., & Lyman, D. J. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000032462.56207.65 · Cited by 52 · see citing works
Flow dynamics across end-to-end vascular bypass graft anastomoses
Kim, Y. H., Chandran, K. B., Bower, T. J., & Corson, J. D. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368624 · Cited by 51 · see citing works
Does compliance mismatch alone cause neointimal hyperplasia?
Okuhn, S. P., Connelly, D. P., Calakos, N., Ferrell, L. D., Man-Xiang, P., & Goldstone, J. (1989) · Journal of Vascular Surgery · doi:10.1016/0741-5214(89)90217-6 · Cited by 49 · see citing works
Zhen, L., Creason, S. A., Simonovsky, F. I., Snyder, J. M., Lindhartsen, S. L., Mecwan, M. M., Johnson, B. W., Himmelfarb, J., & Ratner, B. D. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121174 · Cited by 48 · see citing works
Engineering Design of Vascular Prostheses
How, T. V., Guidoin, R., & Young, S. K. (1992) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1992_206_269_02 · Cited by 48 · see citing works
Wu, M. H.-D., Shi, Q., Sauvage, L. R., Kaplan, S., Hayashida, N., Patel, M. D., Wechezak, A. R., & Walker, M. W. (1993) · Annals of Vascular Surgery · doi:10.1007/bf02001010 · Cited by 38 · see citing works
Sonoda, H., Urayama, S., Takamizawa, K., Nakayama, Y., Uyama, C., Yasui, H., & Matsuda, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10055 · Cited by 33 · see citing works
Postsurgical Changes in Arterial Compliance
Hasson, J. E. (1984) · Archives of Surgery · doi:10.1001/archsurg.1984.01390190032007 · Cited by 32 · see citing works
Sarkar, S., Hillery, C., Seifalian, A. M., & Hamilton, G. (2006) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.07.023 · Cited by 31 · see citing works
Mechanical Properties of Arteries and Arterial Grafts
How, T. V. (1992) · Springer eBooks · doi:10.1007/978-1-4471-1847-3_1 · Cited by 29 · see citing works
Experimental arteriovenous fistulas: treatment with silicone-covered metallic stents.
Geremia, G. K., Bakon, M., Brennecke, L. H., Haklin, M. F., & Silver, B. (1997) · PubMed Central · Cited by 29 · see citing works
Koschwanez, H. E., & Reichert, W. M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00030-9 · Cited by 25 · see citing works
Compliance changes in in-situ femoropopliteal bypass vein grafts
Beard, J. D., & Fairgrieve, J. (1986) · British journal of surgery · doi:10.1002/bjs.1800730313 · Cited by 24 · see citing works
Laser and suture anastomosis: Passive compliance and active force production
Dalsing, M. C., Packer, C. S., Kueppers, P., Griffith, S. L., & Davis, T. E. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120213 · Cited by 22 · see citing works
Biomechanical properties of ascending aorta and pulmonary trunk in pigs and humans
Li, W.-C., Yu, M., Zhang, H., Wang, H. Q., Gang-ming, X., Yao, B., Deng, Z., & Zeng, Y. (2008) · Xenotransplantation · doi:10.1111/j.1399-3089.2008.00498.x · Cited by 21 · see citing works
Textured and Porous Biomaterials
Swanson, W. B., & Ma, P. X. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00039-8 · Cited by 18 · see citing works
Beard, J. D., Lee, R. E., Aldoori, M. I., Baird, R. N., & Horrocks, M. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90174-6 · Cited by 17 · see citing works
Mechanics of End-to-End Artery-to-PTFE Graft Anastomoses
Dobrin, P. B., Mirande, R. A., Kang, S. S., Dong, Q. S., & Mrkvicka, R. (1998) · Annals of Vascular Surgery · doi:10.1007/s100169900161 · Cited by 16 · see citing works
Predicting the compliance of small diameter vascular grafts from uniaxial tensile tests
Stewart, S. F. C., & Lyman, D. J. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90162-v · Cited by 16 · see citing works
Charara, J., Beaudoin, G., Fortin, C., Guidoin, R., Roy, P.-E., Marble, A. E., Schmitter, R., & Paynter, R. W. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90107-6 · Cited by 14 · see citing works
Synthetic vascular graft that heals and regenerates
Zhen, L., Quiroga, E., Creason, S. A., Chen, N., Sapre, T., Snyder, J. M., Lindhartsen, S. L., Fountaine, B. S., Barbour, M. C., Faisal, S., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123206 · Cited by 13 · see citing works
Veloso, A., Laza, J. M., Ruiz‐Rubio, L., Martín, A., Guayara, M. T., Benito‐Vicente, A., Martı́n, C., & Vilas‐Vilela, J. L. (2022) · Materials Today Communications · doi:10.1016/j.mtcomm.2022.104730 · Cited by 13 · see citing works
In Vivo Assessment of Ascending and Arch Aortic Compliance
Tobey, D. J., Reynolds, T. S., Kopchok, G. E., Donayre, C. E., Khoynezhad, A. B., & White, R. A. (2019) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2018.12.060 · Cited by 13 · see citing works
Self-citationJalaie, H., Steitz, J., Afify, M., Barbati, M. E., Hoeft, K., Assar, M. A. M., Hermanns‐Sachweh, B., Tolba, R. H., Jacobs, M. J. H. M., & Schleimer, K. (2019) · Journal of Biomaterials Applications · doi:10.1177/0885328219849368 · Cited by 9 · see citing works
Kasyanov, V. A., Ozolanta, I., Purinya, B. A., Ozols, A., & Kancevich, V. (2003) · Mechanics of Composite Materials · doi:10.1023/a:1025698628850 · Cited by 9 · see citing works
Mechanical aspects of vascular graft-host artery anastomoses
Chandran, K. B., & Kim, Y.-H. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.310993 · Cited by 7 · see citing works
A rapid in vitro test of the in vivo healing potential of vascular prostheses
Mathisen, S. R., Coan, D. E., Sauvage, L. R., Wu, H., Wechezak, A. R., & Goff, S. G. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210903 · Cited by 3 · see citing works
Microvascular silicon replamineform grafts of 2‐ and 5‐cm lengths: Experimental studies
Berman, D. E., Lineweaver, W., Vasconez, B., & Buncke, H. J. (1986) · Microsurgery · doi:10.1002/micr.1920070307 · Cited by 2 · see citing works
Radionuclide Study of Platelets and Prosthetic Interactions: External Versus Specimen Quantitation
Nordestgaard, A. G., Marcus, C. S., & Wilson, S. E. (1988) · Journal of Investigative Surgery · doi:10.3109/08941938809141073 · Cited by 2 · see citing works
Haubold, A. D., & Borovetz, H. S. (1989) · Springer eBooks · doi:10.1007/978-1-4684-7856-3_22 · Cited by 2 · see citing works
Biomaterials in Vascular Surgery
Back, M. R., & White, R. A. (1996) · Humana Press eBooks · doi:10.1007/978-1-4757-2487-5_12 · Cited by 2 · see citing works
Self-citationWeygang, M. L., Lee, J. M., Wilson, G. J., Klement, P., & Binnington, A. G. (1987) · MRS Proceedings · doi:10.1557/proc-110-63 · Cited by 1 · see citing works
- Authors
- White, R., Goldberg, L., Hirose, F., Klein, S., Bosco, P., Miranda, R., Long, J., Nelson, R., & Shors, E.
- Affiliations
- Harbor–UCLA Medical Center (US)
- Venue
- Biomaterials, Medical Devices, and Artificial Organs
- Publisher
- Informa UK Limited
- Published
- 1983-01
- Volume
- 11
- Issue
- 1
- Pages
- 21-29
- ISSN
- 0090-5488 (ISSN-L)
- OpenAlex
- W2242260155
- Cited by
- 38
- References
- 3
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2012: 1
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials Medical Devices and Artificial Organs (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- graft healing, porosity, pore size, tissue ingrowth, fibrous tissue, graft patency, graft calcification, graft contracture
- MeSH terms
- Animals, Biocompatible Materials, Blood Vessel Prosthesis, Compliance, Dogs, Femoral Artery, Polytetrafluoroethylene, Polyurethanes, Silicone Elastomers, Veins, Wound Healing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review