CoChat

A Performance Standard for Clinical and Functional Observational Battery Examinations of Rats

Open access
Mattsson, Joel L., Spencer, Pamela J., Albee, Ralph R. · 1996 · Journal of the American College of Toxicology
Cited by 117

The DOI matches its Crossref record.

Abstract

Clinical examinations are a key component of all toxicology studies and are a major component of the functional observational battery (FOB). The FOB is a core feature of the USEPA neurotoxicity screening guideline of 1991. The need for well-trained technicians is recognized, but technician competency is virtually always judged subjectively by their supervisors. Although subjective evaluation of performance cannot be replaced, what constitutes satisfactory performance is nebulous and therefore difficult to communicate to trainees and difficult to document. Consequently, a laboratory performance standard, with a clear pass-fail criterion, was developed to address this deficiency. The performance standard was an idealized composite of FOB data from experienced laboratory personnel, each person tested on a separate set of four groups of rats. The rats were examined in random order, and treatments were either (a) saline, (b) chlorpromazine, (c) atropine followed by physostigmine, or (d) amphetamine. Thus, the performance standard was the pattern of scores generated by the four treatments. After training, each technician was individually tested on four groups of rats similarly treated (random order, blind examination). The pattern of scores generated by the technician was compared to the performance standard by calculating a Pearson's cross-correlation coefficient. An r > 0.8 was considered passing. The use of the standard meets several laboratory goals: (a) good science (improved training leads to better studies), (b) documentation of observer competency required by the USEPA neurotoxicity guideline, (c) improved documentation of training for Good Laboratory Practices, and (d) objective documentation of performance for purposes of personnel management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/10915819609008716

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
Mattsson, J. L., Spencer, P. J., & Albee, R. R.
Venue
Journal of the American College of Toxicology
Published
1996-06
Volume
15
Issue
3
Pages
239-254
ISSN
0730-0913 (ISSN-L)
OpenAlex
W1973541617
Cited by
117
References
0
FWCI
1.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Performance Standard for Clinical and Functional Observational Battery Examinations of Rats. https://app.cochat.ai/papers/10.3109/10915819609008716
The paper
Mattsson, J. L., Spencer, P. J., & Albee, R. R. (1996). A Performance Standard for Clinical and Functional Observational Battery Examinations of Rats. Journal of the American College of Toxicology. https://doi.org/10.3109/10915819609008716

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.