Predictive Medicine: Computational Techniques in Therapeutic Decision-Making
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The current paradigm for surgery planning for the treatment of cardiovascular disease relies exclusively on diagnostic imaging data to define the present state of the patient, empirical data to evaluate the efficacy of prior treatments for similar patients, and the judgement of the surgeon to decide on a preferred treatment. The individual variability and inherent complexity of human biological systems is such that diagnostic imaging and empirical data alone are insufficient to predict the outcome of a given treatment for an individual patient. We propose a new paradigm of predictive medicine in which the physician utilizes computational tools to construct and evaluate a combined anatomidphysiologic model to predict the outcome of alternative treatment plans for an individual patient. The predictive medicine paradigm is implemented in a software system developed for Simulation-Based Medical Planning. This system provides an integrated set of tools to test hypotheses regarding the effect of alternate treatment plans on blood flow in the cardiovascular system of an individual patient. It combines an internet-based user interface developed using Java and VRML, image segmentation, geometric solid modeling, automatic finite element mesh generation, computational fluid dynamics, and scientific visualization techniques. This system is applied to the evaluation of alternate, patient-specific treatments for a case of lower extremity occlusive cardiovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Brooks, A. N., & Hughes, T. J. R. (1982) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(82)90071-8 · Cited by 5,332
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Self-citationAn interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
Womersley, J. R. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005276 · Cited by 1,835
Zarins, C. K., Giddens, D. P., Bharadvaj, B. K., Sottiurai, V. S., Mabon, R. F., & Glagov, S. (1983) · Circulation Research · doi:10.1161/01.res.53.4.502 · Cited by 1,485
Self-citationHughes, T. J. R., Franca, L. P., & Hulbert, G. M. (1989) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(89)90111-4 · Cited by 1,458
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
Finite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726
Self-citationShear stress regulation of artery lumen diameter in experimental atherogenesis
Zarins, C. K., Zatina, M. A., Giddens, D. P., Ku, D. N., & Glagov, S. (1987) · Journal of Vascular Surgery · doi:10.1016/0741-5214(87)90048-6 · Cited by 582
Self-citation
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
An image-based modeling framework for patient-specific computational hemodynamics
Antiga, L., Piccinelli, M., Botti, L., Ene-Iordache, B., Remuzzi, A., & Steinman, D. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0420-1 · Cited by 850
SimVascular: An Open Source Pipeline for Cardiovascular Simulation
Updegrove, A., Wilson, N. M., Merkow, J., Lan, H., Marsden, A. L., & Shadden, S. C. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1762-8 · Cited by 651
Vignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.04.014 · Cited by 646
Self-citationPatient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
Kim, H. J., Vignon-Clementel, I. E., Coogan, J. S., Figueroa, C. A., Jansen, K. E., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0083-6 · Cited by 628
Self-citationA coupled momentum method for modeling blood flow in three-dimensional deformable arteries
Figueroa, C. A., Vignon-Clementel, I. E., Jansen, K. E., Hughes, T. J. R., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.11.011 · Cited by 547
Self-citationBerger, S. A., & Jou, L.-D. (2000) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.32.1.347 · Cited by 502
A Framework for Geometric Analysis of Vascular Structures: Application to Cerebral Aneurysms
Piccinelli, M., Veneziani, A., Steinman, D. A., Remuzzi, A., & Antiga, L. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021652 · Cited by 346
On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model
Kim, H. J., Vignon-Clementel, I. E., Figueroa, C. A., LaDisa, J. F., Jansen, K. E., Feinstein, J. A., & Taylor, C. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9760-8 · Cited by 333
Self-citationTaylor, C. A., & Steinman, D. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9901-0 · Cited by 261
Self-citationSurgical process modelling: a review
Lalys, F., & Jannin, P. (2014) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-013-0940-5 · Cited by 258
Mazzeo, M. D., & Coveney, P. V. (2008) · Computer Physics Communications · doi:10.1016/j.cpc.2008.02.013 · Cited by 169
Kadem, M., Garber, L., Abdelkhalek, M., Al-Khazraji, B. K., & Keshavarz-Motamed, Z. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3142058 · Cited by 89
Applicability Analysis of Validation Evidence for Biomedical Computational Models
Pathmanathan, P., Gray, R. A., Romero, V. J., & Morrison, T. M. (2017) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4037671 · Cited by 68
Metadata
- Authors
- Taylor, C. A., Draney, M. T., Ku, J. P., Parker, D., Steele, B. N., Wang, K., & Zarins, C. K.
- Venue
- Computer Aided Surgery
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 4
- Issue
- 5
- Pages
- 231-247
- ISSN
- 1092-9088 (ISSN-L)
- 1097-0150
- OpenAlex
- W4251574976
- Cited by
- 221
- References
- 28
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.