The DOI matches its Crossref record; 115 of the 115 references it cites were found in a registry or an index.
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Abstract
Steady-state evoked potentials can be recorded from the human scalp in response to auditory stimuli presented at rates between 1 and 200 Hz or by periodic modulations of the amplitude and/or frequency of a continuous tone. Responses can be objectively detected using frequency-based analyses. In waking subjects, the responses are particularly prominent at rates near 40 Hz. Responses evoked by more rapidly presented stimuli are less affected by changes in arousal and can be evoked by multiple simultaneous stimuli without significant loss of amplitude. Response amplitude increases as the depth of modulation or the intensity increases. The phase delay of the response increases as the intensity or the carrier frequency decreases. Auditory steady-state responses are generated throughout the auditory nervous system, with cortical regions contributing more than brainstem generators to responses at lower modulation frequencies. These responses are useful for objectively evaluating auditory thresholds, assessing suprathreshold hearing, and monitoring the state of arousal during anesthesia.Los potenciales evocados de estado estable pueden registrarse del cráneo humano en respuesta a estímulos auditivos presentados a tasas de 1 y 200 Hz o por modulaciones periódicas de la amplitud y/o de la frecuencia de un tono continue Las respuestas pueden ser detectadas objetivamente por medio de un análisis frecuencial En sujetos en estado de alerta las respuestas son particularmente prominentes con tasas de estimulación cercanas a 40 Hz. Las respuestas evocadas por estímulos presentados a tasa más rápida resultan menos afectadas por cambios del estado de conciencia y pueden ser evocados por estímulos múltiples simultáneos sin una pérdida significativa de la amplitud. La amplitud de la respuesta aumenta conforme la profundidad de la modulación o de la intensidad aumenta. El retraso de fase de la respuesta aumenta conforme la intensidad de la frecuencia portadora aumenta. Las respuestas auditivas de estado estable se generan a todo lo largo del sistema nervioso auditivo; las regiones corticales contribuyen más que los generadores del tallo cerebral en las respuestas de frecuencias más bajas. Estas respuestas son útiles para evaluar objetivamente los umbrales de audición y permiten también evaluar la audición supraliminar y monitorizar el estado de conciencia durante la anestesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
An Introduction to Multivariate Statistical Analysis
Muirhead, R. J., & Anderson, T. W. (1986) · Journal of Business & Economic Statistics · doi:10.2307/1391399 · Cited by 9,082
An Introduction to Multivariate Statistical Analysis.
Skinner, C. J., & Anderson, T. W. (1985) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2981950 · Cited by 3,245
Statistics of Directional Data.
Gokhale, D. V., & Mardia, K. V. (1973) · Biometrics · doi:10.2307/2529189 · Cited by 2,442
Statistical Analysis of Circular Data.
Lange, N., & Fisher, N. I. (1995) · Journal of the American Statistical Association · doi:10.2307/2291098 · Cited by 2,146
Statistical Analysis of Circular Data
Fisher, N. I. (1993) · Cambridge University Press eBooks · doi:10.1017/cbo9780511564345 · Cited by 1,670
Statistics of Directional Data
(1972) · Elsevier eBooks · doi:10.1016/c2013-0-07425-7 · Cited by 1,637
Statistics of Directional Data
Watson, G. S. (1973) · Technometrics · doi:10.1080/00401706.1973.10489127 · Cited by 1,499
The Generalization of Student's Ratio
Hotelling, H. (1931) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177732979 · Cited by 1,492
Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
A 40-Hz auditory potential recorded from the human scalp.
Galambos, R., Makeig, S., & Talmachoff, P. J. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.4.2643 · Cited by 1,247
The Generalization of Student’s Ratio
Hotelling, H. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-0919-5_4 · Cited by 1,083
Temporal modulation transfer functions based upon modulation thresholds
Viemeister, N. F. (1979) · The Journal of the Acoustical Society of America · doi:10.1121/1.383531 · Cited by 736
Time Series Data Analysis and Theory
Wegman, E. J., & Brillinger, D. R. (1976) · Technometrics · doi:10.2307/1267927 · Cited by 689
Tests of significance in harmonic analysis
Fisher, R. A. (1929) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1929.0151 · Cited by 672
Synchronization of fast (30-40 Hz) spontaneous cortical rhythms during brain activation
Steriade, M., Amzica, F., & Contreras, D. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-01-00392.1996 · Cited by 646
Schuster, A. (1898) · Terrestrial Magnetism · doi:10.1029/tm003i001p00013 · Cited by 629
Magnetic field tomography of coherent thalamocortical 40-Hz oscillations in humans.
Ribary, U., Ioannides, A. A., Singh, K. D., Hasson, R., Bolton, J. P., Lado, F., Mogilner, A., & Llinás, R. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.24.11037 · Cited by 541
XII. On the resultant of a large number of vibrations of the same pitch and of arbitrary phase
Rayleigh, L. (1880) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448008626893 · Cited by 535
Some characteristics of average steady-state and transient responses evoked by modulated light
Regan, D. (1966) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(66)90088-5 · Cited by 524
Periodicity coding in the inferior colliculus of the cat. I. Neuronal mechanisms
Langner, G., & Schreiner, C. E. (1988) · Journal of Neurophysiology · doi:10.1152/jn.1988.60.6.1799 · Cited by 508
Clinical Findings for a Group of Infants and Young Children with Auditory Neuropathy
Rance, G., Beer, D. E., Cone-Wesson, B., Shepherd, R. K., Dowell, R. C., King, A. M., Rickards, F. W., & Clark, G. M. (1999) · Ear and Hearing · doi:10.1097/00003446-199906000-00006 · Cited by 460
Methods of Analysis of Brain Electrical and Magnetic Signals
Gevins, A. S., & Rémond, A. (1987) · Medical Entomology and Zoology · Cited by 451
Intracerebral Sources of Human Auditory Steady-State Responses
Herdman, A. T., Lins, O., Van Roon, P., Stapells, D. R., Scherg, M., & Picton, T. W. (2002) · Brain Topography · doi:10.1023/a:1021470822922 · Cited by 389
Self-citationHuman Brain Electrophysiology. Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Picton, T. (1990) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199007000-00010 · Cited by 372
Self-citationRepresentation of the temporal envelope of sounds in the human brain
Giraud, A.-L., Lorenzi, C., Ashburner, J., Wable, J., Johnsrude, I., Frackowiak, R., & Kleinschmidt, A. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.3.1588 · Cited by 353
Başar-Eroglu, C., Strüber, D., Schürmann, M., Stadler, M., & Başar, E. (1996) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00051-7 · Cited by 339
A new statistic for steady-state evoked potentials
Victor, J. D., & Mast, J. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90099-p · Cited by 315
Krishna, B. S., & Semple, M. N. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.255 · Cited by 313
Roß, B., Borgmann, C., Draganova, R., Roberts, L. E., & Pantev, C. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.429600 · Cited by 302
Auditory steady-state responses to multiple simultaneous stimuli
Lins, O. G., & Picton, T. W. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(95)00048-w · Cited by 300
Self-citationBetween sound and perception: reviewing the search for a neural code
Eggermont, J. J. (2001) · Hearing Research · doi:10.1016/s0378-5955(01)00259-3 · Cited by 275
Invariant Reversible QEEG Effects of Anesthetics
John, E. R., Prichep, L. S., Kox, W., Valdés-Sosa, P., Bosch-Bayard, J., Aubert, E., Tom, M., diMichele, F., & Gugino, L. D. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0507 · Cited by 274
Potentials evoked by the sinusoidal modulation of the amplitude or frequency of a tone
Picton, T. W., Skinner, C. R., Champagne, S. C., Kellett, A. J. C., & Maiste, A. C. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395560 · Cited by 256
Self-citationSteriade, M., Timofeev, I., Dürmüller, N., & Grenier, F. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.1.483 · Cited by 253
Tonotopic organization of the sources of human auditory steady-state responses
Pantev, C., Roberts, L. E., Elbert, T., Roβ, B., & Wienbruch, C. (1996) · Hearing Research · doi:10.1016/s0378-5955(96)00133-5 · Cited by 248
Human Auditory Steady State Potentials
Stapells, D. R., Linden, D., Suffield, J. B., Hamel, G., & Picton, T. W. (1984) · Ear and Hearing · doi:10.1097/00003446-198403000-00009 · Cited by 246
Self-citationDynamics of Sensory and Cognitive Processing by the Brain
(1988) · Springer Series in Brain Dynamics · doi:10.1007/978-3-642-71531-0 · Cited by 239
Scalp-recorded early responses in man to frequencies in the speech range
Moushegian, G., Rupert, A. L., & Stillman, R. D. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90223-x · Cited by 221
Yvert, B. (2001) · Cerebral Cortex · doi:10.1093/cercor/11.5.411 · Cited by 204
Neale, M. C., & Cardon, L. R. (1992) · Methodology for Genetic Studies of Twins and Families · doi:10.1007/978-94-015-8018-2_12 · Cited by 204
Neuromagnetic steady-state responses to auditory stimuli
Hari, R., Hämäläinen, M., & Joutsiniemi, S.-L. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398093 · Cited by 197
Evidence for cortical origin of the 40 Hz auditory evoked response in man
Mäkelä, J. P., & Hari, R. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90101-5 · Cited by 193
Roß, B., Picton, T. W., & Pantev, C. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00285-x · Cited by 191
Self-citationThe Associations Between 40 Hz-EEG and the Middle Latency Response of the Auditory Evoked Potential
Başar, E., Rosen, B., Başar-Eroglu, C., & Greitschus, F. (1987) · International Journal of Neuroscience · doi:10.3109/00207458708985933 · Cited by 187
Gutschalk, A., Mase, R., Roth, R., Ille, N., Rupp, A., Hähnel, S., Picton, T. W., & Scherg, M. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00019-x · Cited by 183
Self-citationDobie, R. A., & Wilson, M. J. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417933 · Cited by 178
Meuret, P., Backman, S. B., Bonhomme, V., Plourde, G., & Fiset, P. (2000) · Anesthesiology · doi:10.1097/00000542-200009000-00020 · Cited by 174
A Comparison of Certain Gamma Band (40-HZ) Brain Rhythms in Cat and Man
Galambos, R. (1992) · Induced Rhythms in the Brain · doi:10.1007/978-1-4757-1281-0_11 · Cited by 165
Human auditory steady-state evoked potentials during selective attention
Linden, R. D., Picton, T. W., Hamel, G., & Campbell, K. B. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90184-2 · Cited by 163
Self-citationAuditory evoked potentials indicate the loss of neuronal oscillations during general anaesthesia
Madler, C., & Pöppel, E. (1987) · Die Naturwissenschaften · doi:10.1007/bf00367044 · Cited by 155
Aoyagi, M., Kiren, T., Kim, Y., Suzuki, Y., Fuse, T., & Koike, Y. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90218-p · Cited by 154
THE AUDITORY EVOKED RESPONSE AS AN INDICATOR OF AWARENESS
THORNTON, C., Barrowcliffe, M., Konieczko, K., VENTHAM, P., Doré, C. J., Newton, D. E. F., & JONES, J. G. (1989) · British Journal of Anaesthesia · doi:10.1093/bja/63.1.113 · Cited by 154
Does anesthesia cause loss of consciousness?
Kulli, J. C., & Koch, C. (1991) · Trends in Neurosciences · doi:10.1016/0166-2236(91)90172-q · Cited by 146
Bonhomme, V. L., Fiset, P., Meuret, P., Backman, S. B., Plourde, G., Paus, T., Bushnell, M. C., & Evans, A. C. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.3.1299 · Cited by 142
Human Auditory Steady-State Response During General Anesthesia
Plourde, G., & Picton, T. W. (1990) · Anesthesia & Analgesia · doi:10.1213/00000539-199011000-00002 · Cited by 136
Self-citationMeasurement of spatial contrast sensitivity with the swept contrast VEP
Norcia, A. M., Tyler, C. W., Hamer, R. D., & Wesemann, W. (1989) · Vision Research · doi:10.1016/0042-6989(89)90048-5 · Cited by 136
Madler, C., Keller, I., Schwender, D., & Pöppel, E. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/66.1.81 · Cited by 133
Gap detection with sinusoids and noise in normal, impaired, and electrically stimulated ears
Moore, B. C. J., & Glasberg, B. R. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.396054 · Cited by 133
Relationship of transient and steady-state auditory evoked fields
Pantev, C., Elbert, T. R., Makeig, S., Hampson, S. R., Eulitz, C., & Hoke, M. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90015-h · Cited by 131
Human Auditory Steady State Evoked Potentials during Sleep
Linden, R. D., Campbell, K. B., Hamel, G., & Picton, T. W. (1985) · Ear and Hearing · doi:10.1097/00003446-198505000-00008 · Cited by 130
Self-citationLevi, E. C., Folsom, R. C., & Dobie, R. A. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90063-7 · Cited by 129
Rapid objective refraction using evoked brain potentials.
Regan, D. M. (1973) · PubMed · Cited by 126
Auditory steady-state responses: threshold prediction using phase coherence
Stapells, D. R., Makeig, S., & Galambos, R. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90024-1 · Cited by 123
Ketamine increases the amplitude of the 40-Hz auditory steady-state response in humans
Plourde, G., Baribeau, J., & Bonhomme, V (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.5.524 · Cited by 121
A MEASURE OF CONSCIOUSNESS AND MEMORY DURING ISOFLURANE ADMINISTRATION: THE COHERENT FREQUENCY †
Munglani, R., Andrade, J., Sapsford, D. J., Baddeley, A., & Jones, J. G. (1993) · British Journal of Anaesthesia · doi:10.1093/bja/71.5.633 · Cited by 120
A frequency domain technique for characterizing nonlinearities in biological systems
Regan, M. P., & Regan, D. (1988) · Journal of Theoretical Biology · doi:10.1016/s0022-5193(88)80323-0 · Cited by 118
Intracerebral dipole source localization for FFT power maps
Lehmann, D., & Michel, C. M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90022-c · Cited by 117
Reliability estimates for steady-state evoked potentials
Picton, T. W., Vajsar, J., Rodriguez, R. A., et al. (1987) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(87)90039-6 · Cited by 115
Self-citationAn adaptive filter for steady-state evoked responses
Tang, Y., & Norcia, A. M. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)00309-3 · Cited by 114
Franowicz, M. N., & Barth, D. S. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.74.1.96 · Cited by 113
Weighted averaging of steady-state responses
John, M. S., Dimitrijevic, A., & Picton, T. W. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00456-4 · Cited by 110
Self-citationBrain dynamics : progress and perspectives
Başar, E., & Bullock, T. H. (1989) · Springer eBooks · Cited by 109
Responses to clicks from the human brain: Some depth electrographic observations
Chatrian, G. E., Petersen, M. C., & Lazarte, J. A. (1960) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(60)90024-9 · Cited by 104
Objective response detection in the frequency domain
Dobie, R. A., & Wilson, M. J. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90040-v · Cited by 103
Woldorff, M. G., Hansen, J. C., & Hillyard, S. A. (1987) · PubMed · Cited by 98
Clinical investigation of lesions of the visual pathway: a new objective technique.
Regan, D., & Heron, J. (1969) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.32.5.479 · Cited by 97
Weighted averaging — theory and application to electric response audiometry
Hoke, M., Ross, B., Wickesberg, R. E., & Lütkenhöner, B. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90078-6 · Cited by 96
Scalp Potentials Evoked by Amplitude-Modulated Tones in Dyslexia
McAnally, K. I., & Stein, J. F. (1997) · Journal of Speech Language and Hearing Research · doi:10.1044/jslhr.4004.939 · Cited by 90
The use of phase in the detection of auditory steady-state responses
Picton, T. W., Dimitrijevic, A., John, M. S., & Roon, P. V. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00608-3 · Cited by 90
Self-citationThe Human Auditory Steady-State Evoked Potentials
Plourde, G., Stapells, D. R., & Picton, T. W. (1991) · Acta Oto-Laryngologica · doi:10.3109/00016489109136793 · Cited by 83
Self-citationPlace specificity of multiple auditory steady-state responses
Herdman, A. T., Picton, T. W., & Stapells, D. R. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1506367 · Cited by 82
Self-citationAuditory Development Reflected by Middle Latency Response
McGee, T., & Kraus, N. (1996) · Ear and Hearing · doi:10.1097/00003446-199610000-00008 · Cited by 80
The 40 hertz auditory event-related potential: Normal values and effects of lesions
Spydell, J. D., Pattee, G. L., & Goldie, W. D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90014-0 · Cited by 78
The frequency-following response to continuous tones in humans
Batra, R., Kuwada, S., & Maher, V. L. (1986) · Hearing Research · doi:10.1016/0378-5955(86)90037-7 · Cited by 74
Dimitrijevic, A., John, M. S., Roon, P. V., & Picton, T. W. (2001) · Ear and Hearing · doi:10.1097/00003446-200104000-00003 · Cited by 71
Self-citationSteady-state evoked potentials to amplitude-modulated tones
Rickards, F., & Clark, G. M. (1984) · Minerva Access (University of Melbourne) · Cited by 71
Dutton, R. C., Smith, W. D., Rampil, I. J., Chortkoff, B. S., & Eger, E. I. (1999) · Anesthesiology · doi:10.1097/00000542-199911000-00010 · Cited by 69
The amplitude-modulation following response in young and aged human subjects
Boettcher, F. A., Poth, E. A., Mills, J. H., & Dubno, J. R. (2001) · Hearing Research · doi:10.1016/s0378-5955(00)00255-0 · Cited by 66
Galambos, R., & Makeig, S. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.404383 · Cited by 64
Generation of human auditory steadystate responses (SSRs). I: Stimulus rate effects
Azzena, G. B., Conti, G., Santarelli, R., et al. (1995) · Hearing Research · doi:10.1016/0378-5955(94)00184-r · Cited by 64
Effect of Isoflurane on the Auditory Steady-state Response and on Consciousness in Human Volunteers
Plourde, G., Villemure, C., Fiset, P., Bonhomme, V. L., & Backman, S. B. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00008 · Cited by 63
Possibilities and limitations of weighted averaging
Lütkenhöner, B., Hoke, M., & Pantev, C. (1985) · Biological Cybernetics · doi:10.1007/bf00449599 · Cited by 62
Santarelli, R., Maurizi, M., Conti, G., et al. (1995) · Hearing Research · doi:10.1016/0378-5955(94)00185-s · Cited by 61
An experimental study on the generator of amplitudemodulation following response
Kiren, T., Aoyagi, M., Furuse, H., et al. (1994) · Acta Oto-Laryngologica · doi:10.3109/00016489409128297 · Cited by 61
New developments in event-related potentials
Heinze, H., Münte, T. F., & Mangun, G. R. (1993) · Birkhäuser-Verlag eBooks · Cited by 58
Auditory Brainstem Frequency Following Responses to Waveform Envelope Periodicity
Hall, J. W. (1979) · Science · doi:10.1126/science.472748 · Cited by 56
Neurophysiological Evidence of Auditory Channel Anomalies in Developmental Dysphasia
Stefanatos, G. A., Green, G. G. R., & Ratcliff, G. G. (1989) · Archives of Neurology · doi:10.1001/archneur.1989.00520440053021 · Cited by 55
Intracerebral dipole sources of EEG FFT power maps
Lehmann, D., & Michel, C. M. (1989) · Brain Topography · doi:10.1007/bf01128852 · Cited by 53
Plourde, G., & Villemure, C. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199601000-00013 · Cited by 49
Modulation of auditory responses during oddball tasks
Rockstroh, B. S., Müller, M., Heinz, A., Wagner, M., Berg, P., & Elbert, T. R. (1996) · Biological Psychology · doi:10.1016/0301-0511(95)05175-9 · Cited by 46
Anesthetic Control of 40-Hz Brain Activity and Implicit Memory
Schwender, D., Madler, C., Klasing, S., Peter, K., & Pöppel, E. (1994) · Consciousness and Cognition · doi:10.1006/ccog.1994.1009 · Cited by 41
Effects of voluntary movements on early auditory brain responses
Makeig, S., M�ller, M., & Rockstroh, B. S. (1996) · Experimental Brain Research · doi:10.1007/bf00229149 · Cited by 39
40 Hz — middle latency auditory evoked response in comatose patients
Firsching, R. P., Luther, J., Eidelberg, E., Brown, W. E., Story, J. L., & Boop, F. A. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90018-6 · Cited by 39
Generation of auditory steady-state responses: linearity assessment.
Santarelli, R., & Conti, G. (1999) · PubMed · Cited by 29
Regan, D. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90140-1 · Cited by 28
Andrade, J., Sapsford, D. J., Jeevaratnum, D., et al. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199612000-00026 · Cited by 27
Isoflurane Attenuates Resonant Responses of Auditory Thalamic Neurons
Tennigkeit, F., Ries, C. R., Schwarz, D. W. F., & Puil, E. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.2.591 · Cited by 27
40 Hz Auditory steady-state response and EEG spectral edge frequency during sufentanil anaesthesia
Gilron, I., Plourde, G., Marcantoni, W., & Varin, F. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013248 · Cited by 26
Auditory and visual event-related perturbations in the 40 Hz auditory steady-state response
Rohrbaugh, J., Varner, J. L., Paige, S. R., Eckardt, M. J., & Ellingson, R. J. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90213-4 · Cited by 21
Plourde, G. (1999) · Anesthesiology · doi:10.1097/00000542-199911000-00006 · Cited by 18
Rohrbaugh, J., Varner, J. L., Paige, S. R., Eckardt, M. J., & Ellingson, R. J. (1989) · Biological Psychology · doi:10.1016/0301-0511(89)90022-7 · Cited by 18
Improving the Reliability of the Auditory Middle latency Response by Monitoring EEG Delta Activity
McGee, T., Kraus, N., Killion, M. C., Rosenberg, R., & King, C. D. (1993) · Ear and Hearing · doi:10.1097/00003446-199304000-00002 · Cited by 11
Parker, D., & O'dwyer, D. (1998) · International Journal of Audiology · doi:10.3109/00206099809072990 · Cited by 7
Monitoring of Stimulus-Induced 40Hz Brain Oscillations
(1997) · The Internet Journal of Anesthesiology · doi:10.5580/27f7 · Cited by 3
Cited by
Hearing Impairment and Cognitive Energy: The Framework for Understanding Effortful Listening (FUEL)
Pichora-Fuller, M. K., Kramer, S. E., Eckert, M. A., Edwards, B., Hornsby, B. W. Y., Humes, L. E., Lemke, U., Lunner, T., Matthen, M., Mackersie, C. L., et al. (2016) · Ear & Hearing · doi:10.1097/aud.0000000000000312 · Cited by 1,318
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Phase-Locked Responses to Speech in Human Auditory Cortex are Enhanced During Comprehension
Peelle, J. E., Gross, J., & Davis, M. H. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs118 · Cited by 568
Thut, G., Schyns, P. G., & Gross, J. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00170 · Cited by 560
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Metadata
- Authors
- Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D.
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2003-01
- Volume
- 42
- Issue
- 4
- Pages
- 177-219
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W1976359337
- Cited by
- 846
- References
- 115
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.