Correlation between hyperacusis measurements in daily ENT practice
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Olivier M. Meeus*a, Mattias Spaepena, Dirk De Ridderb & Paul H. Van de Heyningaa *University Department of Otorhinolaryngology and Head and Neck Surgeryb University Department of Neurosurgery Brain Research Center Antwerp for Innovative & Interdisciplinary Neuromodulation (BRAI2N) Antwerp University Hospital (UZA), University of Antwerp, Edegem, BelgiumOlivier M. Meeus, University Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital (UZA), University of Antwerp, Wilrijkstraat 10, B-2650 Edegem, Belgium. E-mail: olivier.meeus@uza.be AbstractThe aim of this study was to investigate hyperacusis measurement tools and to assess the correlation between diagnostic methods for hyperacusis in daily ENT practice. We studied two hyperacusis questionnaires: the Hyperacusis Questionnaire (HQ) and the Multiple-Activity Scale for Hyperacusis (MASH), audiometric measurements (uncomfortable loudness level (ULL) and dynamic range (DR)), and the questions ‘Do you have a lower tolerance for noise… ?’ and ‘Are you afraid of noise?’ Hyperacusis was assessed in 46 patients presenting with primary complaints of tinnitus. A validated Dutch version of the HQ is provided. A correlation was found between scores on the HQ and the MASH (p=0.000, R2=0.34). Significantly higher scores for both questionnaires were found in patients reporting decreased sound tolerance (p=0.000 and 0.002, respectively) or fear of noise (p=0.002 and 0.004, respectively). Overall, no correlations were found between scores on questionnaires and audiometric values including ULL and DR. The HQ and MASH were confirmed to be valid measurement tools for hyperacusis complaints. No correlations were found between audiometric measurements and hyperacusis complaints.SumarioEl objetivo de este estudio fue investigar las herramientas para mediar la hiperacusia y evaluar la correlación entre métodos diagnósticos para hiperacusia en la práctica diaria otorrinolaringológica. Estudiamos dos cuestionarios para hiperacusia: El Cuestionario de Hiperacusia (HQ) y la Escala de Multi-actividades para Hiperacusia (MASH), mediciones audiométricas (el nivel molesto de intensidad (ULL) y el rango dinámico (DR); y las preguntas ¿Tiene usted poca tolerancia al ruido?, y ¿Le da miedo el ruido?. La hiperacusia se evaluó en 46 pacientes cuya principal molestia era el acufeno. Se presenta una versión validada de HQ en holandés. Se encontró una correlación entre las puntuaciones del HQ y del MASH (p=0.000, R2=0.34). Se encontraron puntuaciones significativamente más altas para ambos cuestionarios en pacientes que reportaban una tolerancia disminuida al ruido (p=0.000 y 0.002, respectivamente) o miedo al ruido (p=0.002 y 0.004 respectivamente). En general, no se encontraron correlaciones entre la puntuación en los cuestionarios y los valores audiométricos de ULL y DR. Se confirmó que el HQ y el MASH son herramientas válidas para la medición de las quejas de una hiperacusia. No se encontró correlación entre las mediciones audiométricas y las quejas de una hiperacusia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychometric Normalization of a Hyperacusis Questionnaire
Khalfa, S., Dubal, S., Veuillet, E., Perez-Diaz, F., Jouvent, R., & Collet, L. (2002) · ORL · doi:10.1159/000067570 · Cited by 488
Hypersensitivity to sound: Questionnaire data, audiometry and classification
Anari, M., Axelsson, A., Eliasson, A., & Magnusson, L. (1999) · Scandinavian Audiology · doi:10.1080/010503999424653 · Cited by 271 · cited 1×
“In contrast to previous studies (Anari et al, 1999; Andersson et al, 2002; Khalfa et al, 2002; Dauman & Bouscau-Faure, 2005; Coelho et al, 2007), patients could also respond ‘I don’t know’ to Question 1 and Question 2 (Table 3 and Table 4).”
ResultFactors influencing tinnitus loudness and annoyance
Hiller, W., & Goebel, G. (2006) · Archives of Otolaryngology–Head & Neck Surgery · doi:10.1001/archotol.132.12.1323 · Cited by 209 · cited 1×
“(Folmer et al, 1999; Hiller & Goebel, 2006)”
Andersson, G., Lindvall, N., Hursti, T., Carlbring, P., & Andersson, G. (2002) · International Journal of Audiology · doi:10.3109/14992020209056075 · Cited by 189
Assessment and amelioration of hyperacusis in tinnitus patients
Dauman, R., & Bouscau-Faure, F. (2005) · Acta Oto-Laryngologica · doi:10.1080/00016480510027565 · Cited by 179 · cited 6×
“In contrast to previous studies (Anari et al, 1999; Andersson et al, 2002; Khalfa et al, 2002; Dauman & Bouscau-Faure, 2005; Coelho et al, 2007), patients could also respond ‘I don’t know’ to Question 1 and Question 2 (Table 3 and Table 4).”
BackgroundMethodResultInfluentialTinnitus retraining therapy: A different view on tinnitus
Jastreboff, P. J., & Jastreboff, M. M. (2006) · ORL · doi:10.1159/000090487 · Cited by 154 · cited 2×
“Another defi nition of hyperacusis is ‘physical discomfort resulting from an exposure to moderate or even weak sound that would not evoke a similar reaction in an average person’ (Jastreboff & Jastreboff, 2006).”
Background
Cited by
A review of hyperacusis and future directions: Part I. Definitions and manifestations
Tyler, R. S., Pienkowski, M., Roncancio, E. R., Jun, H. J., Brozoski, T., Dauman, N., Coelho, C. B., Andersson, G., Keiner, A. J., Cacace, A. T., et al. (2014) · American Journal of Audiology · doi:10.1044/2014_aja-14-0010 · Cited by 329
Fackrell, K., Fearnley, C., Hoare, D. J., & Sereda, M. (2015) · BioMed Research International · doi:10.1155/2015/290425 · Cited by 110
Sex Differences in the Response to Different Tinnitus Treatment
Van der Wal, A., Luyten, T., Cardon, E., Jacquemin, L., Vanderveken, O. M., Topsakal, V., Van de Heyning, P., De Hertogh, W., Van Looveren, N., Van Rompaey, V., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00422 · Cited by 46
Clinical and investigational tools for monitoring noise-induced hyperacusis
Jahn, K. N. (2022) · The Journal of the Acoustical Society of America · doi:10.1121/10.0012684 · Cited by 20
Smees, R., Simner, J., Hoare, D. J., & Ward, J. (2025) · International Journal of Audiology · doi:10.1080/14992027.2024.2419558 · Cited by 7
“Using Khalfa et al.’s (2002) threshold ( > 28 score): 30% of our misophonic sample would be classified as having hyperacusis (36/119), if we were to base this classification solely on the HQ. Applying Meeus et al.’s (2010) slightly more lenient threshold ( > 26 score) would raise the percentage classified as having hy…”
Influential
Metadata
- Authors
- Meeus, O. M., Spaepen, M., Ridder, D. D., & Heyning, P. H. V. D.
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2010-01
- Volume
- 49
- Issue
- 1
- Pages
- 7-13
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W1970842535
- Cited by
- 99
- References
- 6
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation between hyperacusis measurements in daily ENT practice. https://app.cochat.ai/papers/10.3109/14992020903160868
- The paper
- Meeus, O. M., Spaepen, M., Ridder, D. D., & Heyning, P. H. V. D. (2010). Correlation between hyperacusis measurements in daily ENT practice. International Journal of Audiology. https://doi.org/10.3109/14992020903160868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.