CoChat

Correlation between hyperacusis measurements in daily ENT practice

Meeus, Olivier M., Spaepen, Mattias, Ridder, Dirk De, Heyning, Paul H. Van de · 2010 · International Journal of Audiology
Cited by 99

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Olivier M. Meeus*a, Mattias Spaepena, Dirk De Ridderb & Paul H. Van de Heyningaa *University Department of Otorhinolaryngology and Head and Neck Surgeryb University Department of Neurosurgery Brain Research Center Antwerp for Innovative & Interdisciplinary Neuromodulation (BRAI2N) Antwerp University Hospital (UZA), University of Antwerp, Edegem, BelgiumOlivier M. Meeus, University Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital (UZA), University of Antwerp, Wilrijkstraat 10, B-2650 Edegem, Belgium. E-mail: olivier.meeus@uza.be AbstractThe aim of this study was to investigate hyperacusis measurement tools and to assess the correlation between diagnostic methods for hyperacusis in daily ENT practice. We studied two hyperacusis questionnaires: the Hyperacusis Questionnaire (HQ) and the Multiple-Activity Scale for Hyperacusis (MASH), audiometric measurements (uncomfortable loudness level (ULL) and dynamic range (DR)), and the questions ‘Do you have a lower tolerance for noise… ?’ and ‘Are you afraid of noise?’ Hyperacusis was assessed in 46 patients presenting with primary complaints of tinnitus. A validated Dutch version of the HQ is provided. A correlation was found between scores on the HQ and the MASH (p=0.000, R2=0.34). Significantly higher scores for both questionnaires were found in patients reporting decreased sound tolerance (p=0.000 and 0.002, respectively) or fear of noise (p=0.002 and 0.004, respectively). Overall, no correlations were found between scores on questionnaires and audiometric values including ULL and DR. The HQ and MASH were confirmed to be valid measurement tools for hyperacusis complaints. No correlations were found between audiometric measurements and hyperacusis complaints.SumarioEl objetivo de este estudio fue investigar las herramientas para mediar la hiperacusia y evaluar la correlación entre métodos diagnósticos para hiperacusia en la práctica diaria otorrinolaringológica. Estudiamos dos cuestionarios para hiperacusia: El Cuestionario de Hiperacusia (HQ) y la Escala de Multi-actividades para Hiperacusia (MASH), mediciones audiométricas (el nivel molesto de intensidad (ULL) y el rango dinámico (DR); y las preguntas ¿Tiene usted poca tolerancia al ruido?, y ¿Le da miedo el ruido?. La hiperacusia se evaluó en 46 pacientes cuya principal molestia era el acufeno. Se presenta una versión validada de HQ en holandés. Se encontró una correlación entre las puntuaciones del HQ y del MASH (p=0.000, R2=0.34). Se encontraron puntuaciones significativamente más altas para ambos cuestionarios en pacientes que reportaban una tolerancia disminuida al ruido (p=0.000 y 0.002, respectivamente) o miedo al ruido (p=0.002 y 0.004 respectivamente). En general, no se encontraron correlaciones entre la puntuación en los cuestionarios y los valores audiométricos de ULL y DR. Se confirmó que el HQ y el MASH son herramientas válidas para la medición de las quejas de una hiperacusia. No se encontró correlación entre las mediciones audiométricas y las quejas de una hiperacusia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/14992020903160868

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 99

Metadata

Authors
Meeus, O. M., Spaepen, M., Ridder, D. D., & Heyning, P. H. V. D.
Venue
International Journal of Audiology
Published
2010-01
Volume
49
Issue
1
Pages
7-13
ISSN
  • 1499-2027 (ISSN-L)
  • 1708-8186
OpenAlex
W1970842535
Cited by
99
References
6
FWCI
1.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation between hyperacusis measurements in daily ENT practice. https://app.cochat.ai/papers/10.3109/14992020903160868
The paper
Meeus, O. M., Spaepen, M., Ridder, D. D., & Heyning, P. H. V. D. (2010). Correlation between hyperacusis measurements in daily ENT practice. International Journal of Audiology. https://doi.org/10.3109/14992020903160868

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.