CoChat

H-coil repetitive transcranial magnetic stimulation for the treatment of bipolar depression: an add-on, safety and feasibility study

Harel, Eiran Vadim, Zangen, Abraham, Roth, Yiftach, Reti, Irving, Braw, Yoram, Levkovitz, Yechiel · 2011 · The World Journal of Biological Psychiatry
Cited by 126

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: The H1-Coil is a novel transcranial magnetic stimulation (TMS) device capable of inducing a magnetic field with a deeper and wider distribution than standard coils. This pilot study evaluated the safety and feasibility of the H1-Coil as adjuvant treatment for bipolar depression (BPD). METHODS: Nineteen patients diagnosed as having BPD and under treatment with psychotropic medication were enrolled in the study. They received daily prefrontal repetitive TMS (rTMS: 20 Hz, 2 s on, 20 s off, totaling 1680 stimuli) every weekday for four consecutive weeks. The primary outcome measure was the change from baseline in the Hamilton Depression Rating Scale (HDRS-24) score a week after the last treatment session. RESULTS: A significant mean decrease of 12.9 points in the HDRS-24 scale (P< 0.001) was found. Response rate was 63.2% and remission rate was 52.6%. Treatment was well tolerated in terms of headache and overall discomfort, and there were no significant change in cognitive functioning or mood switches. One patient had a short induced generalized seizure without complications. CONCLUSIONS: An add-on H-coil rTMS treatment protocol in BPD subjects indicated improvement in bipolar depression symptoms. Sham-control studies to further determine the efficacy and safety of the H-Coil for BPD are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/15622975.2010.510893

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 126

Metadata

Authors
Harel, E. V., Zangen, A., Roth, Y., Reti, I., Braw, Y., & Levkovitz, Y.
Venue
The World Journal of Biological Psychiatry
Published
2010-09-21
Volume
12
Issue
2
Pages
119-126
ISSN
  • 1562-2975 (ISSN-L)
  • 1814-1412
OpenAlex
W2153621572
Cited by
126
References
2
FWCI
5.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: H-coil repetitive transcranial magnetic stimulation for the treatment of bipolar depression: an add-on, safety and feasibility study. https://app.cochat.ai/papers/10.3109/15622975.2010.510893
The paper
Harel, E. V., Zangen, A., Roth, Y., Reti, I., Braw, Y., & Levkovitz, Y. (2011). H-coil repetitive transcranial magnetic stimulation for the treatment of bipolar depression: an add-on, safety and feasibility study. The World Journal of Biological Psychiatry. https://doi.org/10.3109/15622975.2010.510893

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.