Implant fixation improved by close fit Cylindrical implant – bone interface studied in rabbits
Open accessThe DOI matches its Crossref record.
Abstract
Cylindric titanium implants of three different diameters were inserted and stabilized in a 3.7-mm burr hole in the rabbit tibia. The purpose of the study was to investigate the interfacial reaction to screw- and cylinder-shaped implants, and to determine if there is a critical gap at the insertion between bone and implant that prevents direct cortical bone apposition on the implant. The study indicated that this critical gap approached zero.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Animal models for implant biomaterial research in bone: A review
AO Research Institute, A. F., Pearce, A., Richards, R., Milz, S., Schneider, E., & Pearce, S. (2007) · European Cells and Materials · doi:10.22203/ecm.v013a01 · Cited by 1,289
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
Søballe, K., Hansen, E. S., B.‐Rasmussen, H., Jørgensen, P. H., & Bünger, C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100216 · Cited by 506
Implant surface characteristics and their effect on osseointegration
Barfeie, A., Wilson, J., & Rees, J. (2015) · British Dental Journal · doi:10.1038/sj.bdj.2015.171 · Cited by 292
The jumping distance revisited: An experimental study in the dog
Botticelli, D., Berglundh, T., Buser, D., & Lindhe, J. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140105.x · Cited by 248
Immediate and Delayed Implant Placement Into Extraction Sockets: A 5‐Year Report
Polizzi, G., Grunder, U., Goené, R., Hatano, N., Henry, P., Jackson, W. J., Kawamura, K., Renouard, F., Rosenberg, R., Triplett, G., et al. (2000) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2000.tb00111.x · Cited by 216
Jansen, J. A., van de Waerden, J. P. C. M., Wolke, J. G. C., & De Groot, K. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250805 · Cited by 216
Nano hydroxyapatite structures influence early bone formation
Meirelles, L., Arvidsson, A., Andersson, M., Kjellin, P., Albrektsson, T., & Wennerberg, A. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31744 · Cited by 212
Self-citation
Metadata
- Authors
- Carlsson, L., Röstlund, T., Albrektsson, B., & Albrektsson, T.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1988-01
- Volume
- 59
- Issue
- 3
- Pages
- 272-275
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2159992957
- Cited by
- 195
- References
- 0
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.